Non-invasive blood pressure measurements and aortic blood flow velocity in neonates

被引:9
|
作者
Rahiala, E
Tikanoja, T
机构
[1] Department of Paediatrics, Kuopio University Hospital
关键词
blood pressure; oscillometric method; newborn infant; aortic coarctation; Doppler echocardiography;
D O I
10.1016/S0378-3782(97)01883-5
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
We studied the systolic blood pressure difference between the upper and the lower extremities in healthy newborn infants and the effect of the isthmic narrowing of the aorta on the possible difference. The blood pressure was measured with an oscillometric blood pressure device from every extremity of 36 healthy infants aged 2-5 days. A Doppler echocardiography was performed for each infant to measure the aortic blood flow velocity in the ascending aorta and in the aortic arch above and below the isthmic narrowing. The mean blood pressure readings (S.D.) were the following: the right arm 76.8 (7.3)/48.1 (6.9), the left arm 77.5 (7.4)/51.6 (7.0), the right thigh 77.7 (7.1)/40.7 (5.8), the left thigh 76.8 (6.4)/39.6 (5.8), the right calf 75.5 (7.1)/46.6 (5.7) and the left calf 77.1 (8.6)/48.7 (6.7). The aortic blood flow was faster below the isthmic narrowing of the aorta (1.15+/-0.19 m/s) than in the ascending aorta (0.93+/-0.12 m/s) or in the aortic arch above the isthmus (0.99+/-0.15 m/s). The calculated pressure gradient between the ascending aorta and aorta below the isthmus was 2.0+/-1.8 mmHg and between opposite sides of the isthmus 1.5+/-1.2 mmHg. Unlike in childhood and adolescence, the systolic blood pressure in the lower extremities of healthy newborn infants is not higher than in the upper extremities. The physiological narrowing of the aortic arch does not explain this phenomenon. If blood pressure measurements are performed on a neonate to rule out aortic coarctation, the readings obtained must be interpreted in respect to normal values in newborns. (C) 1997 Elsevier Science Ireland Ltd.
引用
收藏
页码:107 / 112
页数:6
相关论文
共 50 条
  • [1] NON-INVASIVE MEASUREMENT OF HUMAN AORTIC BLOOD-FLOW VELOCITY
    PINARDI, G
    SAINZ, A
    ROBERTS, VC
    [J]. ACTA PHYSIOLOGICA LATINOAMERICANA, 1975, 25 : 56 - 56
  • [2] APPROPRIATE DIMENSIONS OF THE OCCLUDING CUFF FOR NON-INVASIVE BLOOD-PRESSURE MEASUREMENTS IN NEONATES
    KELLEROVA, E
    KITTOVA, M
    [J]. PHYSIOLOGIA BOHEMOSLOVACA, 1979, 28 (05): : 445 - 446
  • [3] NON-INVASIVE VS INVASIVE BLOOD-PRESSURE MEASUREMENTS
    GRUNDY, BL
    PROCOPIO, P
    SIEBER, FE
    [J]. CRITICAL CARE MEDICINE, 1981, 9 (03) : 267 - 267
  • [4] The association of aortic pulse wave velocity with non-invasive central and brachial systolic blood pressure
    Cameron, JD
    McGrath, BP
    [J]. JOURNAL OF HYPERTENSION, 2004, 22 : S199 - S199
  • [5] A comparison of invasive and non-invasive arterial blood pressure measurements in the neonate
    Shea, J. E. O'
    Dempsey, E. M.
    [J]. ACTA PAEDIATRICA, 2007, 96 : 190 - 191
  • [6] A COMPARISON OF INVASIVE AND NON-INVASIVE ARTERIAL BLOOD PRESSURE MEASUREMENTS IN THE NEONATE
    O'Shea, J.
    Dempsey, E.
    [J]. IRISH JOURNAL OF MEDICAL SCIENCE, 2010, 179 : S174 - S174
  • [7] Clinical Study of Continuous Non-Invasive Blood Pressure Monitoring in Neonates
    Rao, Anoop
    Eskandar-Afshari, Fatima
    Weiner, Ya'el
    Billman, Elle
    McMillin, Alexandra
    Sella, Noa
    Roxlo, Thomas
    Liu, Junjun
    Leong, Weyland
    Helfenbein, Eric
    Walendowski, Alan
    Muir, Arthur
    Joseph, Alexandria
    Verma, Archana
    Ramamoorthy, Chandra
    Honkanen, Anita
    Green, Gabrielle
    Drake, Keith
    Govindan, Rathinaswamy B.
    Rhine, William
    Quan, Xina
    [J]. SENSORS, 2023, 23 (07)
  • [8] A NON-INVASIVE CORRELATE OF ASCENDING AORTIC BLOOD FLOW ACCELERATION
    REITAN, JA
    SMITH, NT
    KADIS, LB
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1970, 42 (01) : 87 - &
  • [9] NON-INVASIVE PULSED DOPPLER BLOOD-FLOW MEASUREMENT IN NEONATES
    BERMAN, W
    ELDRIDGE, M
    GREENE, D
    YABEK, S
    HARTLEY, C
    [J]. CIRCULATION, 1979, 60 (04) : 205 - 205
  • [10] Acquiring the oscillometric envelopes for non-invasive blood pressure measurements
    Gersak, Gregor
    [J]. ELEKTROTEHNISKI VESTNIK-ELECTROCHEMICAL REVIEW, 2009, 76 (03): : 97 - 102