Characterization of an inorganic polymer coagulant and coagulation behavior for humic acid/algae-polluted water treatment: polymeric zinc-ferric-silicate-sulfate coagulant

被引:12
|
作者
Liao, Yong [1 ,2 ]
Tang, Xiaomin [1 ,3 ]
Yang, Qingqing [1 ,2 ]
Chen, Wei [1 ,2 ]
Liu, Bingzhi [1 ,2 ]
Zhao, Chuanliang [1 ,2 ]
Zhai, Jun [1 ,2 ]
Zheng, Huaili [1 ,2 ]
机构
[1] Chongqing Univ, Key Lab Three Gorges Reservoir Reg Ecoenvironm, State Minist Educ, Chongqing 400045, Peoples R China
[2] Chongqing Univ, Natl Ctr Int Res Low Carbon & Green Bldg, Chongqing 400045, Peoples R China
[3] Chongqing Technol & Business Univ, Coll Environm & Resources, Chongqing Key Lab Catalysis & Environm New Mat, Chongqing 400067, Peoples R China
来源
RSC ADVANCES | 2017年 / 7卷 / 32期
基金
中国国家自然科学基金;
关键词
POLYALUMINUM CHLORIDE COAGULANT; ALUMINUM-HYDROXIDE GELS; ORGANIC-MATTER; MICROCYSTIS-AERUGINOSA; COMPOSITE COAGULANT; DRINKING-WATER; ALGAE REMOVAL; WASTE-WATER; EFFICIENCY; IRON;
D O I
10.1039/c7ra00232g
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Algae and algae organic matter (AOM) are not the sole pollutants in algae-polluted water. Other pollutants such as colloidal particles and natural organic matter should be simultaneously removed and might influence the treatment of algae and AOM. A new polymeric zinc-ferric-silicate-sulfate (PZFSiS) coagulant was prepared, and the relationship between its structure and performance in the treatment of humic acid (HA)/algae-polluted water was discussed. PZFSiS coagulants prepared under different conditions had different distributions of Fe(III) species. The coagulant possessing the highest Fe-b content was able to treat turbidity and HA well. As a copolymer of Fe(III), Zn(II) and Si(IV), PZFSiS had a positive charge in water and thus neutralized the negative surface charges of pollutants. The adsorption of hydroxyl polymer formed by Fe/Zn during the hydrolysis process contributed to the removal of organic matter. The dosage of PZFSiS and pH significantly influenced pollutant removal. Colloidal particles in the water competed with the organic matter, markedly decreasing the removal efficiency of organic matter by coagulation.
引用
收藏
页码:19856 / 19862
页数:7
相关论文
共 3 条
  • [1] Characterization and coagulation-flocculation behavior of an inorganic polymer coagulant - poly-ferric-zinc-sulfate
    Wei, Yanxin
    Dong, Xiongzi
    Ding, Aimin
    Xie, Dong
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2016, 58 : 351 - 356
  • [2] Characterization and coagulation performance of a novel inorganic polymer coagulant-Poly-zinc-silicate-sulfate
    Zeng, Yubin
    Park, Junboum
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2009, 334 (1-3) : 147 - 154
  • [3] Removal of Microcystis aeruginosa and its extracellular organic matters by using covalently bonded coagulant: An alternative choice in enhanced coagulation for algae-polluted water treatment
    Nie, Yong
    Zhang, Rui
    Li, Sha
    Xia, Wei
    Ma, Jiangya
    JOURNAL OF CLEANER PRODUCTION, 2023, 419