Within-session test-retest reliability of pressure pain threshold and mechanical temporal summation in healthy subjects

被引:31
|
作者
Mailloux, Catherine [1 ]
Beaulieu, Louis-David [2 ]
Wideman, Timothy H. [3 ]
Masse-Alarie, Hugo [1 ]
机构
[1] Univ Laval, Ctr Interdisciplinaire Rech Readaptat & Integrat, Quebec City, PQ, Canada
[2] Univ Quebec Chicoutimi, BioNR Res Lab, Chicoutimi, PQ, Canada
[3] McGill Univ, Sch Phys & Occupat Therapy, Montreal, PQ, Canada
来源
PLOS ONE | 2021年 / 16卷 / 01期
关键词
LOW-BACK-PAIN; CENTRAL SENSITIZATION; MODULATION; EXERCISE; SENSITIVITY; INDIVIDUALS; PARAMETERS; HYPOALGESIA; PROTOCOL; PEOPLE;
D O I
10.1371/journal.pone.0245278
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective To determine the absolute and relative intra-rater within-session test-retest reliability of pressure pain threshold (PPT) and mechanical temporal summation of pain (TSP) at the low back and the forearm in healthy participants and to test the influence of the number and sequence of measurements on reliability metrics. Methods In 24 participants, three PPT and TSP measures were assessed at four sites (2 at the low back, 2 at the forearm) in two blocks of measurements separated by 20 minutes. The standard error of measurement, the minimal detectable change (MDC) and the intraclass correlation coefficient (ICC) were investigated for five different sequences of measurements (e.g. measurement 1, 1-2, 1-2-3). Results The MDC for the group (MDCgr) for PPT ranged from 28.71 to 50.56 kPa across the sites tested, whereas MDCgr for TSP varied from 0.33 to 0.57 out of 10 (numeric scale). Almost all ICC showed an excellent relative reliability (between 0.80 and 0.97), except when only the first measurement was considered (moderate). Although minimal differences in absolute PPT reliability were present between the different sequences, in general, using only the first measurement increase measurement error. Three TSP measures reduced the measurement error. Discussion We established that two measurements of PPT and three of TSP reduced the measurement error and demonstrated an excellent relative reliability. Our results could be used in future pain research to confirm the presence of true hypo/hyperalgesia for paradigms such as conditioned pain modulation or exercise-induced hypoalgesia, indicated by a change exceeding the measurement variability.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Within-Session Test-Retest Reliability of Pressure Pain Threshold and Mechanical Temporal Summation in Chronic Low Back Pain
    de Oliveira, Fabio Carlos Lucas
    Cossette, Camille
    Mailloux, Catherine
    Wideman, Timothy H.
    Beaulieu, Louis-David
    Masse-Alarie, Hugo
    CLINICAL JOURNAL OF PAIN, 2023, 39 (05): : 217 - 225
  • [2] Pain-free bite force in a healthy population: Within-session test-retest reliability in different sitting positions
    Mitchell, Andrew
    Heales, Luke
    Treleaven, Julia
    Too, Brendan
    Tyrrell, Ryan
    Dinsdale, Alana
    JOURNAL OF ORAL REHABILITATION, 2024, 51 (08) : 1440 - 1449
  • [3] A study of the test-retest reliability of pressure pain threshold in knee osteoarthritis
    Simpson, A. I.
    Wheeler, M.
    Moreton, B.
    Pearson, R.
    Scammell, B.
    Walsh, D. A.
    BRITISH JOURNAL OF SURGERY, 2012, 99 : 37 - 37
  • [4] Test-retest reliability of pressure pain threshold measurements of the upper limb and torso in young healthy women
    Jones, David H.
    Kilgour, Robert D.
    Comtoist, Alain S.
    JOURNAL OF PAIN, 2007, 8 (08): : 650 - 656
  • [5] Test-retest reliability of pressure pain threshold and heat pain threshold as test stimuli for evaluation of conditioned pain modulation
    Kovacevic, Milena
    Klicov, Ljiljana
    Vuklis, Dragana
    Neblett, Randy
    Knezevic, Aleksandar
    NEUROPHYSIOLOGIE CLINIQUE-CLINICAL NEUROPHYSIOLOGY, 2021, 51 (05): : 433 - 442
  • [6] Pressure Pain Threshold in Subjects With Piriformis Syndrome: Test-Retest, Intrarater, and Interrater Reliability, and Minimal Detectible Changes
    Tabatabaiee, Abbas
    Takamjani, Ismail Ebrahimi
    Sarrafzadeh, Javad
    Salehi, Reza
    Ahmadi, Maryam
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2020, 101 (05): : 781 - 788
  • [7] Test-Retest Reliability of Thermal Temporal Summation Using an Individualized Protocol
    Kong, Jiang-Ti
    Johnson, Kevin A.
    Balise, Raymond R.
    Mackey, Sean
    JOURNAL OF PAIN, 2013, 14 (01): : 79 - 88
  • [8] Test-retest reliability of vestibular autorotation testing in healthy subjects
    Guyot, JP
    Psillas, G
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1997, 117 (06) : 704 - 707
  • [9] Within- and between-session test-retest reliability of pressure pain threshold in individuals with lateral elbow tendinopathy (pg P232)
    Hill, C.
    Heales, L.
    Stanton, R.
    Kean, C.
    JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2022, 25 (03) : E12 - E12
  • [10] Test-Retest Instability of Temporal Summation and Conditioned Pain Modulation Measures in Older Adults
    Naugle, Kelly Marie
    Ohlman, Thomas
    Wind, Brandon
    Miller, Leah
    PAIN MEDICINE, 2020, 21 (11) : 2863 - 2876