Tandem calibration methodology: dual nebulizer sample introduction for ICP-MS

被引:18
|
作者
Huxter, V [1 ]
Hamier, J [1 ]
Salin, ED [1 ]
机构
[1] McGill Univ, Dept Chem, Montreal, PQ H3A 2K6, Canada
关键词
D O I
10.1039/b110427f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The application to inductively coupled plasma mass spectrometry (ICP-MS) of a calibration method called the TCM (tandem calibration method) is described. The TCM involves simultaneous introduction of sample and standard into the plasma by two nebulizers operated in parallel. Figures of merit were determined by comparing the results obtained with those produced using the method of standard additions and external standard calibration was used as a probe of the severity of the matrix effect induced. The test solutions in this study contained Cu, Y, Pt and Pb as analytes and 10 mM Ba and 35 mM Na as matrix effect generators. Classical standard addition verified the validity of the TCM and the two methods were shown to be statistically equivalent. The precision of the results obtained was limited by the noise of the sample introduction device (about 4% RSD on difficult samples versus roughly 1% on clean standards), while the accuracy was only slightly limited by the short and long term stability of the arrangement, typically around 2% relative error. The method was easy to implement on existing equipment, inexpensive and potentially suited to automation.
引用
收藏
页码:71 / 75
页数:5
相关论文
共 50 条
  • [1] Tandem calibration methodology: dual nebulizer sample introduction for inductively coupled plasma atomic emission spectrometry
    Hamier, J
    Salin, ED
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (06) : 497 - 505
  • [2] Sample introduction for ICP-MS and ICP-OES
    Gaines, P
    SPECTROSCOPY, 2005, 20 (01) : 20 - 23
  • [3] DRY AEROSOL SAMPLE INTRODUCTION IN ICP-MS
    KARANASSIOS, V
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 138 - ANYL
  • [4] High performance concentric nebulizer for low-flow rate liquid sample introduction to ICP-MS
    Inagaki, Kazumi
    Fujii, Shin-ichiro
    Takatsu, Akiko
    Chiba, Koichi
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (03) : 623 - 630
  • [5] Sample introduction systems for ICP-OES and ICP-MS
    Hutton, RC
    Grote, B
    ANALUSIS, 1996, 24 (9-10) : M29 - M31
  • [6] Determination of trace elements in fuel ethanol by ICP-MS using direct sample introduction by a microconcentric nebulizer
    Tormen, Luciano
    Chaves, Eduardo S.
    Saint'Pierre, Tatiana D.
    Frescura, Vera L. A.
    Curtius, Adilson J.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (09) : 1300 - 1304
  • [7] A convenient sample introduction system for ICP, ICP-MS, and AA
    McLaughlin, Roger
    Cheese, Paula
    Ding, Min
    Ptolemy, Adam
    Conn, April
    Brindle, Ian
    AMERICAN LABORATORY, 2006, 38 (18) : 13 - +
  • [9] The ETV as a thermochemical reactor for ICP-MS sample introduction
    Sturgeon, RE
    Lam, JW
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (05) : 785 - 791
  • [10] The direct analysis of fuel ethanol by ICP-MS using a flow injection system coupled to an ultrasonic nebulizer for sample introduction
    Saint'Pierre, Tatiana D.
    Tormen, Luciano
    Frescura, Vera L. A.
    Curtius, Adilson J.
    Journal of Analytical Atomic Spectrometry, 2006, 21 (11): : 1340 - 1344