Modeling of a Digital Couch for a Proton Treatment Planning System

被引:4
|
作者
Kim, Jin Sung [1 ]
Yoon, Myonggeun [2 ]
Ahn, Sunghwan [2 ]
Shin, Dong Ho [2 ]
Lim, Young-Kyung [2 ]
Park, Sung Yong [2 ]
Lee, Se Byeong [2 ]
Cho, Kwan Ho [2 ]
机构
[1] Samsung Med Ctr, Dept Radiat Oncol, Seoul 135710, South Korea
[2] Natl Canc Ctr, Proton Therapy Ctr, Goyang 411769, South Korea
关键词
Couch; Treatment planning system; Range; Spread-out Bragg peak; Proton therapy; CARBON-FIBER TABLETOP; PHOTON-BEAM ATTENUATION; RADIOTHERAPY;
D O I
10.3938/jkps.55.1640
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
To evaluate the modeling of a proton treatment couch for a commercial proton treatment planning system, a real couch was scanned using a CT scanner and was inserted into the commercial proton treatment planning system (TPS, Eclipse, v8.12) by replacing the CT couch of all transverse CT slices. The couch inserted in the proton TPS was validated by dosimetric measurements of percentage depth dose (PDD), transverse profile, and output. When the beam direction was perpendicular to the proton couch (0 degrees in our configuration), insertion of the proton couch shortened the range of the proton beam by 0.99 +/- 0.01 cm and caused the spread-out Bragg peak (SOBP) to vary by 0.10 +/- 0.09 cm. Increasing the angle of the beam from 0 degrees to 55 degrees increased the average range shift of the proton beam from 0.99 cm to 1.70 cm, but had little effect on the SOBP, which varied by less than 0.1 cm. Insertion of the proton couch had no effect on the transverse dose profiles at various depths. When we measured the doses at points set at various depths, located in the middle of the SOBP for various beam energies, with/without proton couch, we found no distinct changes in output with insertion of the couch, resulting in a variation of less than 1%. These results suggest that dosimetric factors, such as range, profile, and output factors, were little changed by insertion of a proton couch whereas the beam range depended greatly on both couch insertion and beam angle. Using the inserted CT scanned proton couch in the TPS, we found that the range of the proton beam was shortened by similar to 0.7 cm in the TPS, a similar to 0.3 cm difference from the actual measurement. The difference between the computed and the measured ranges was compensated by assigning appropriate densities to the inserted proton couch, called a digital couch. Measured and computed percent depth dose (PDD) with the digital couch showed that the beam range and the SOBP were well matched for various beam angles, with differences of 0.01 +/- 0.02 cm and 0.12 +/- 0.03 cm, respectively. Our results suggest that a digital couch with relevant density assignment may be a good solution for proton couch modeling, which can be used for a commercial proton TPSs.
引用
收藏
页码:1640 / 1648
页数:9
相关论文
共 50 条
  • [1] Study On the Modeling of Digital Couch for Proton Treatment Planning System
    Yoon, M.
    Kim, J.
    Ahn, S.
    Cheong, M.
    Lim, Y.
    Kim, D.
    Shin, D.
    Lee, S.
    Park, S.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [2] Modeling of couch transmission in the RayStation treatment planning system
    Savini, Alessandro
    Bartolucci, Floriana
    Fidanza, Christian
    Rosica, Federica
    Orlandi, Giovanni
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (05): : 735 - 740
  • [3] Treatment couch modeling in Elekta Monaco treatment planning system
    Huertas, C.
    Ferrer, C.
    Huerga, C.
    Mas, I.
    Serrada, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S389 - S390
  • [4] Modeling a carbon fiber couch in a commercial Treatment Planning System
    Gomez Pardos, R.
    Navarro Jimenez, D.
    Ramirez Munoz, A.
    Ambroa Rey, E.
    Colomer Truyols, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S775 - S776
  • [5] iBEAM evo Couch Modeling and Validation for Monaco Treatment Planning System
    Thiyagarajan, R.
    Mariagandhi, E.
    Kataria, T.
    Manigandan, D.
    TamilSelvan
    Kamaraj, D.
    Veni, M.
    Nambiraj, N. Arunai
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E303 - E303
  • [6] Modeling of carbon fiber couch attenuation properties with a commercial treatment planning system
    Mihaylov, I. B.
    Corry, P.
    Yan, Y.
    Ratanatharathorn, V.
    Moros, E. G.
    [J]. MEDICAL PHYSICS, 2008, 35 (11) : 4982 - 4988
  • [7] Validation of Elekta couch modeling for dose calculation in the Monaco treatment planning system
    Poli, E.
    Reis, P.
    Prudencio, L.
    Galhardas, J.
    Ribeiro, T.
    Malveiro, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S991 - S991
  • [8] Evaluation for the usability of the Varian Standard Couch modeling using Treatment Planning System
    Yang, Y. M.
    Song, Y. M.
    Kim, J. M.
    Choi, J. M.
    Choi, B. K.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S1000 - S1000
  • [9] EVALUATION OF THE DOSIMETRIC ACCURACY OF COUCH MODELING FOR RADIOTHERAPY TREATMENT PLANNING
    Tillikainen, L.
    Kauppinen, J.
    Torsti, T.
    Van Esch, A.
    Huyskens, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S408 - S409
  • [10] The clinical significance of couch top modeling in VMAT and IMRT treatment planning
    Chan, G. H.
    Chin, L.
    [J]. MEDICAL PHYSICS, 2012, 39 (07) : 4635 - 4636