Implementation and operational feasibility of SAMBA I HIV-1 semi-quantitative viral load testing at the point-of-care in rural settings in Malawi and Uganda

被引:6
|
作者
Gueguen, Monique [1 ]
Nicholas, Sarala [2 ]
Poulet, Elisabeth [2 ]
Schramm, Birgit [2 ]
Szumilin, Elisabeth [1 ]
Wolters, Liselotte [1 ]
Wapling, Johanna [1 ]
Ajule, Ephrahim [1 ]
Rakesh, Ankur [1 ]
Mwenda, Reuben [3 ]
Kiyaga, Charles [4 ]
Balkan, Suna [1 ]
机构
[1] Medecins Sans Frontieres, Paris, France
[2] Epictr, Paris, France
[3] Malawi Minist Hlth, Blantyre, Malawi
[4] Uganda Minist Hlth, Kampala, Uganda
关键词
SAMBA I; POC testing; Malawi; Uganda; descriptive analysis; ANTIRETROVIRAL THERAPY; SCALE-UP;
D O I
10.1111/tmi.13519
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objective We monitored a large-scale implementation of the Simple Amplification-Based Assay semi-quantitative viral load test for HIV-1 version I (SAMBA I Viral Load = SAMBA I VL) within Medecins Sans Frontieres' HIV programmes in Malawi and Uganda, to assess its performance and operational feasibility. Methods Descriptive analysis of routine programme data between August 2013 and December 2016. The dataset included samples collected for VL monitoring and tested using SAMBA I VL in five HIV clinics in Malawi (four peripheral health centres and one district hospital), and one HIV clinic in a regional referral hospital in Uganda. SAMBA I VL was used for VL testing in patients who had been receiving ART for between 6 months and ten years, to determine whether plasma VL was above or below 1000 copies/mL of HIV-1, reflecting ART failure or efficacy. Randomly selected samples were quantified with commercial VL assays. SAMBA I instruments and test performance, site throughput, and delays in communicating results to clinicians and patients were monitored. Results Between August 2013 and December 2016 a total of 60 889 patient samples were analysed with SAMBA I VL. Overall, 0.23% of initial SAMBA I VL results were invalid; this was reduced to 0.04% after repeating the test once. Global test failure, including instrument failure, was 1.34%. Concordance with reference quantitative testing of VL was 2620/2727, 96.0% (1338/1382, 96.8% in Malawi; 1282/1345, 95.3% in Uganda). For Chiradzulu peripheral health centres and Arua Hospital HIV clinic, where testing was performed on-site, same-day results were communicated to clinicians for between 91% and 97% of samples. Same-day clinical review was obtained for 84.7% across the whole set of samples tested. Conclusions SAMBA I VL testing is feasible for monitoring cohorts of 1000 to 5000 ART-experienced patients. Same-day results can be used to inform rapid clinical decision-making at rural and remote health facilities, potentially reducing time available for development of resistance and conceivably helping to reduce morbidity and mortality.
引用
收藏
页码:184 / 194
页数:11
相关论文
共 20 条
  • [1] Performance of the SAMBA I and II HIV-1 Semi-Q Tests for viral load monitoring at the point-of-care
    Goel, Neha
    Ritchie, Allyson V.
    Mtapuri-Zinyowera, Sekesai
    Zeh, Clement
    Stepchenkova, Tetiana
    Lehga, Jesse
    De Ruiter, Annemiek
    Farleigh, Laura E.
    Edemaga, Daniel
    So, Rosario
    Sembongi, Hiroshi
    Wisniewski, Craig
    Nadala, Lourdes
    Schito, Marco
    Lee, Helen
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2017, 244 : 39 - 45
  • [2] Study To Evaluate the Performance of a Point-of-Care Whole-Blood HIV Viral Load Test (SAMBA II HIV-1 Semi-Q Whole Blood)
    Brook, Gary
    Stepchenkova, Tetiana
    Ali, Innocent M.
    Chipuka, Sandra
    Goel, Neha
    Lee, Helen
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2021, 59 (03)
  • [3] SAMBA HIV Semiquantitative Test, a New Point-of-Care Viral-Load-Monitoring Assay for Resource-Limited Settings
    Ritchie, Allyson V.
    Ushiro-Lumb, Ines
    Edemaga, Daniel
    Joshi, Hrishikesh A.
    De Ruiter, Annemiek
    Szumilin, Elisabeth
    Jendrulek, Isabelle
    McGuire, Megan
    Goel, Neha
    Sharma, Pia I.
    Allain, Jean-Pierre
    Lee, Helen H.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2014, 52 (09) : 3377 - 3383
  • [4] Point-of-Care Cepheid Xpert HIV-1 Viral Load Test in Rural African Communities Is Feasible and Reliable
    Moyo, Sikhulile
    Mohammed, Terence
    Wirth, Kathleen E.
    Prague, Melanie
    Bennett, Kara
    Holme, Molly Pretorius
    Mupfumi, Lucy
    Sebogodi, Philemon
    Moraka, Natasha O.
    Boleo, Corretah
    Maphorisa, Comfort N.
    Seraise, Boitumelo
    Gaseitsiwe, Simani
    Musonda, Rosemary M.
    van Widenfelt, Erik
    Powis, Kathleen M.
    Gaolathe, Tendani
    Tchetgen, Eric J. Tchetgen
    Makhema, Joseph M.
    Essex, Max
    Lockman, Shahin
    Novitsky, Vladimir
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2016, 54 (12) : 3050 - 3055
  • [5] Leukodepletion as a Point-of-Care Method for Monitoring HIV-1 Viral Load in Whole Blood
    Titchmarsh, Logan
    Zeh, Clement
    Verpoort, Thierry
    Allain, Jean-Pierre
    Lee, Helen
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2015, 53 (04) : 1080 - 1086
  • [6] Performance evaluation of the point-of-care SAMBA I and II HIV-1 Qual whole blood tests
    Ritchie, Allyson V.
    Goel, Neha
    Sembongi, Hiroshi
    Lehga, Jesse
    Farleigh, Laura E.
    Edemaga, Daniel
    Wisniewski, Craig A.
    Lee, Helen H.
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2016, 237 : 143 - 149
  • [7] Diagnostic Accuracy of the Point-of-Care Xpert HIV-1 Viral Load Assay in a South African HIV Clinic
    Garrett, Nigel J.
    Drain, Paul K.
    Werner, Lise
    Samsunder, Natasha
    Karim, Salim S. Abdool
    [J]. JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2016, 72 (02) : E45 - E48
  • [8] Performance of point-of-care Xpert HIV-1 plasma viral load assay at a tertiary HIV care centre in Southern India
    Swathirajan, Chinnambedu Ravichandran
    Vignesh, Ramachandran
    Boobalan, Jayaseelan
    Solomon, Sunil Suhas
    Saravanan, Shanmugam
    Balakrishnan, Pachamuthu
    [J]. JOURNAL OF MEDICAL MICROBIOLOGY, 2017, 66 (10) : 1379 - 1382
  • [9] An investigation of fingerstick blood collection for point-of-care HIV-1 viral load monitoring in South Africa
    Maiers, T. J.
    Gous, N.
    Nduna, M.
    McFall, S. M.
    Kelso, D. M.
    Fisher, M. J.
    Palamountain, K. M.
    Scott, L. E.
    Stevens, W. S.
    [J]. SAMJ SOUTH AFRICAN MEDICAL JOURNAL, 2015, 105 (03): : 228 - 231
  • [10] Monitoring of HIV-1 RNA with point-of-care cepheid Xpert HIV-1 viral load in rural African communities is feasible and reliable in the era of broad scale up of ART
    Moyo, S.
    Mohammed, T.
    Wirth, K.
    Bennett, K.
    Holme, M. P.
    Mupfumi, L.
    Sebogodi, P.
    Moraka, N. O.
    Boleo, C.
    Maphorisa, C. N.
    Seraise, B.
    Gaseitsiwe, S.
    Musonda, R. M.
    van Widenfelt, E.
    Powis, K. M.
    Gaolathe, T.
    Tchetgen, E. J. Tchetgen
    Makhema, J. M.
    Essex, M.
    Lockman, S.
    Novitsky, V.
    [J]. JOURNAL OF THE INTERNATIONAL AIDS SOCIETY, 2016, 19