A new analytical method for the determination of beta-blockers and one metabolite in the influents and effluents of three urban wastewater treatment plants

被引:0
|
作者
Iancu, Vasile-ion [1 ,2 ]
Radu, Gabriel-Lucian [2 ]
Scutariu, Roxana [1 ]
机构
[1] Natl Res & Dev Inst Ind Ecol ECOIND, Drumul Podu Dambovitei St,71-73,Sect 6, Bucharest, Romania
[2] Univ Politehn Bucuresti, Fac Appl Chem & Mat Sci, 1-7 Polizu Str, Bucharest 011061, Romania
关键词
TANDEM MASS-SPECTROMETRY; SEWAGE-TREATMENT PLANTS; SOLID-PHASE EXTRACTION; PHARMACEUTICALS; REMOVAL; ENVIRONMENT; DRUGS; RIVER; RISK; FATE;
D O I
10.1039/c9ay01597c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pharmaceuticals are emerging contaminants in waste waters from where they are discharged into surface water, so they may be harmful to aquatic organisms. Beta-blockers are consumed in high tonnage every year owing to the rise in cardiovascular disease of the population, and are incompletely metabolized. They are eliminated from the body as the parent drugs or as metabolites into wastewater. A sensitive method using off-line solid-phase extraction (SPE) and liquid chromatography coupled with mass spectrometry (LC-MS/MS) has been developed for the determination of 6 beta-blockers (bisoprolol, nadolol, betaxolol, atenolol, propranolol, pindolol) and one metabolite (4-hydroxy propranolol) in the influents and effluents of three urban waste water treatment plants (WWTPs). Extraction of the compounds was performed on Oasis C18 cartridges at pH 10 adjusted with ammonium hydroxide. As the LC mobile phase, formic acid 0.1% in water and methanol in gradient elution was used to separate the analytes in 13 minutes on a Luna C18 column kept at 45 degrees C. A linear response was obtained for all substances in the range of 1-100 ng mL(-1) with determination coefficients >0.99. The parameters of the SPE procedure and of the LC-MS method were optimized to obtain the best results. The method was validated and beta-blocker recoveries after SPE in waste water were in the range of 71.2-103.3% with satisfactory intra-day and inter-day precision (RSD%) being located between 4.7 and 8.4%, and 8.1 and 14.4%, respectively. Optimization of LC-MS parameters generated low LOQ values between 0.34 and 7.37 ng mL(-1). Atenolol was detected in all samples at higher average concentrations which ranged between 94.6 ng L-1 and 208.6 ng L-1 (effluent samples, influents). The other 3 beta-blockers: bisoprolol, betaxolol and propranolol were detected in influents in mean concentrations of 100.1 ng L-1, 44.9 ng L-1 and 26.8 ng L-1 and in effluents in mean concentrations of 51 ng L-1, 16.9 ng L-1 and 19.4 ng L-1. Propranolol was eliminated with the lowest average yields ranging from 25.19% to 31.78%, whereas atenolol, bisoprolol and betaxolol were eliminated from WWTPs with average yields ranging from 44.97 to 60.96%, 46.8 to 52.9% and 47.05 to 69.08%, respectively. Results obtained suggest that the adopted wastewater treatment processes are not efficient to remove these compounds and by penetrating into surface waters through evacuated effluents they can adversely affect aquatic organisms.
引用
收藏
页码:4668 / 4680
页数:13
相关论文
共 8 条
  • [1] Determination of perfluorinated compounds in influents/effluents from wastewater treatment plants using ion chromatography
    Gavilan, Irma
    Becerril, Eduardo
    Santos, Elvira
    Olmos, Jesus
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 251
  • [2] Determination of antibiotics in influents and effluents of wastewater-treatment-plants in the Czech Republic - development and application of the SPE and a UHPLC-ToFMS method
    Tylova, Tereza
    Flieger, Miroslav
    Olsovska, Jana
    ANALYTICAL METHODS, 2013, 5 (08) : 2110 - 2118
  • [3] Determination of analytical error function for beta-blockers as a possible weighting method for the estimation of the regression parameters
    Modamio, P
    Lastra, CF
    Marino, EL
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (04) : 401 - 408
  • [4] Analytical determination of oestrogenic endocrine disruptors: the method of choice for wastewater treatment plant effluents
    Cerna, Tereza
    Michalikova, Klara
    Semerad, Jaroslav
    Cajthaml, Tomas
    ENVIRONMENTAL CHEMISTRY, 2021, 18 (04) : 143 - 155
  • [5] LC-MS/MS determination of antiretroviral drugs in influents and effluents from wastewater treatment plants in KwaZulu-Natal, South Africa
    Abafe, Ovokeroye A.
    Spath, Jana
    Fick, Jerker
    Jansson, Stina
    Buckley, Chris
    Stark, Annegret
    Pietruschka, Bjoern
    Martincigh, Bice S.
    CHEMOSPHERE, 2018, 200 : 660 - 670
  • [6] Evaluating the polar organic chemical integrative sampler for the monitoring of beta-blockers and hormones in wastewater treatment plant effluents and receiving surface waters
    Jacquet, Romain
    Miege, Cecile
    Bados, Philippe
    Schiavone, Severine
    Coquery, Marina
    ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2012, 31 (02) : 279 - 288
  • [7] Simultaneous determination of several veterinary pharmaceuticals in effluents from urban, livestock and slaughterhouse wastewater treatment plants using a simple chromatographic method
    Cavenati, Simone
    Carvalho, Pedro N.
    Almeida, C. Marisa R.
    Basto, M. Clara P.
    Vasconcelos, M. Teresa S. D.
    WATER SCIENCE AND TECHNOLOGY, 2012, 66 (03) : 603 - 611
  • [8] Development and validation of a new spectrofluorimetric method for the determination of some beta-blockers through fluorescence quenching of eosin Y. Application to content uniformity test
    Derayea, Sayed M.
    Omar, Mahmoud A.
    Abdel-Lateef, Mohamed Aboel-Kasem
    Hassan, Ahmed I.
    OPEN CHEMISTRY, 2016, 14 (01): : 258 - 266