Using Energy-Dispersive X-Ray Fluorescence Spectrometer with Three Dimensional-Polarization Optics

被引:2
|
作者
Yonezawa, Shuhei [1 ]
Hokura, Akiko [1 ]
Matsuda, Kenji [2 ]
Kimoto, Takeshi [3 ]
Nakai, Izumi [1 ]
机构
[1] Tokyo Univ Sci, Fac Sci, Dept Appl Chem, Shinjuku Ku, Tokyo 1628601, Japan
[2] SPECTRIS Co Ltd, PANalyt Div, Minato Ku, Tokyo 1050013, Japan
[3] KIMOTO ELECT CO LTD, Tennoji Ku, Osaka 5430024, Japan
关键词
suspended particulate matter; PM2.5; trace elements; diurnal variation; XRF; MULTIELEMENT ANALYSIS; EMISSION-SPECTROMETRY; POLLUTION;
D O I
10.2116/bunsekikagaku.59.23
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have developed an XRF method for the determination of trace elements in Suspended particulate matter. A total of 11 elements (Al, Si, S, Cl, K, Ca, Mn, Fe, Cu, Zn, Pb) were successfully detected from the SPM on an air filter after 6 h of sampling (air Volume, 6 ill) by applying secondary targets of Ti, Ge and Mo for the primary X-rays from a Gd X-ray tube. Reference filter samples were prepared by dropping the mixed element standard Solutions of known chemical concentrations onto a polycarbonate filter. The obtained calibration curves were linear with square values of the correlation coefficients, R-2, of 0.9491 - 0.9999 for S, K, Ca, Cr, Mn, Fe, Cu, Zn, Pb. A good matching was observed between the calibration curves and those prepared from standard reference materials of SPM (NIST SRM 2783). The minimum detection limits for S, Zn and Pb were found to be 3.6, 1.0, 3.5 ng cm(-2), respectively, indicating that highly sensitive analyses were possible for these elements by the present method. This analytical method was applied to air monitoring samples measured at Tsuruhashi, Osaka city (Japan). They were conducted four times by the mission of FECOA during 2006 and 2007. The trace-element levels for PM2.5 samples collected every 6 h by an air sampler onto filters for 5 days were determined by the present method. As a result, the diurnal variations of the concentrations (ng m(-3)) of S, K, Ca, Fe, Cu, Zn, Pb in the samples were Successfully monitored. Especially, a strong positive cord relation was observed between the concentration of S in PM2.5 and SO2 in air, and an increase in the concentration Of Sulfur during a west wind was observed. The results Suggest that a possible source of sulfur for a PM2.5 sample seemed to exist to the west of the sampling point.
引用
收藏
页码:23 / 33
页数:11
相关论文
共 50 条
  • [1] Quantitative analysis of iodine and bromine in soil using an energy-dispersive X-ray fluorescence spectrometer with three-dimensional polarized optics
    Tokoro, Masato
    Zhiyuan, Shi
    Yamaji, Isao
    Takaku, Yuichi
    Sakaguchi, Aya
    Hokura, Akiko
    [J]. ANALYTICAL SCIENCES, 2024, 40 (06) : 1157 - 1166
  • [2] Advances in energy-dispersive X-ray fluorescence
    Kramar, U
    [J]. JOURNAL OF GEOCHEMICAL EXPLORATION, 1997, 58 (01) : 73 - 80
  • [3] Application of x-ray optics to energy-dispersive spectroscopy
    McCarthy, JJ
    McMillan, DJ
    [J]. MICROSCOPY AND MICROANALYSIS, 1998, 4 (06) : 632 - 639
  • [4] A SPECTROMETER FOR X-RAY ENERGY-DISPERSIVE DIFFRACTION USING SYNCHROTRON RADIATION
    OLSEN, JS
    BURAS, B
    GERWARD, L
    STEENSTRUP, S
    [J]. JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1981, 14 (10): : 1154 - 1158
  • [5] Energy-dispersive x-ray fluorescence spectrometer with capillary optics for the chemical analysis of atmospheric aerosols with high time resolution
    Holynska, B
    Ptasinski, J
    Maenhaut, W
    Annegarn, HJ
    [J]. JOURNAL OF AEROSOL SCIENCE, 1997, 28 (08) : 1455 - 1463
  • [6] Gauge of an energy-dispersive X-ray fluorescence analyzer
    Bukin, KV
    Nakhabtsev, VS
    Romanova, NE
    Kirillov, VN
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1998, 41 (03) : 393 - 397
  • [7] Online monitoring of aerosols with an energy-dispersive X-ray spectrometer
    R. Harmel
    O. Haupt
    W. Dannecker
    [J]. Fresenius' Journal of Analytical Chemistry, 2000, 366 : 178 - 181
  • [8] Online monitoring of aerosols with an energy-dispersive X-ray spectrometer
    Harmel, R
    Haupt, O
    Dannecker, W
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (02): : 178 - 181
  • [9] Measurements of the K X-ray intensity ratios by using energy-dispersive X-ray fluorescence spectrometry
    Guerol, A.
    [J]. APPLIED RADIATION AND ISOTOPES, 2008, 66 (03) : 372 - 376
  • [10] Energy-dispersive X-ray fluorescence analysis in geochemical mapping
    Civici, N
    VanGrieken, R
    [J]. X-RAY SPECTROMETRY, 1997, 26 (04) : 147 - 152