"Reactive" optical sensor for Hg2+ and its application in environmental aqueous media and biological systems

被引:10
|
作者
Chen, Zhi [1 ]
Chen, Jiayun [1 ]
Pan, Dong [2 ]
Li, Hongwei [2 ]
Yao, Yunhui [1 ]
Lyu, Zu [1 ]
Yang, Liting [1 ]
Ma, Li-Jun [1 ,3 ]
机构
[1] South China Normal Univ, Sch Chem & Environm, Guangzhou 510631, Guangdong, Peoples R China
[2] Jilin Univ, State Key Lab Supramol Struct & Mat, 2699,Qianjin St, Changchun 130012, Peoples R China
[3] South China Normal Univ, Key Lab Theoret Chem Environm, Minist Educ, Guangzhou 510006, Guangdong, Peoples R China
关键词
Hg2+; Reactive" sensor; Colorimetric; Fluorescent turn-on; Rhodamine B; RHODAMINE-BASED FLUORESCENT; MERCURY; PROBE; HG(II); IONS; CHEMODOSIMETER; CHEMOSENSOR; EXPOSURE; CU2+;
D O I
10.1007/s00216-017-0189-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new rhodamine B-based "reactive" optical sensor (1) for Hg2+ was synthesized. Sensor 1 shows a unique colorimetric and fluorescent "turn-on" selectivity to Hg2+ over 14 other metal ions with a hypersensitivity (detection limits are 27.6 nM (5.5 ppb) and 6.9 nM (1.4 ppb), respectively) in neutral buffer solution. To test its applicability in the environment, sensor 1 was applied to quantify and visualize low levels of Hg2+ in tap water and river water samples. The results indicate sensor 1 is a highly sensitive fluorescent sensor for Hg2+ with a detection limit of 1.7 ppb in tap water and river water. Moreover, sensor 1 is a convenient visualizing sensor for low levels of Hg2+ (0.1 ppm) in water environment (from colorless to light pink). In addition, sensor 1 shows good potential as a fluorescent visualizing sensor for Hg2+ in fetal bovine serum and living 293T cells. The results indicate that sensor 1 shows good potential as a highly sensitive sensor for the detection of Hg2+ in environmental and biological samples.
引用
收藏
页码:2429 / 2435
页数:7
相关论文
共 50 条
  • [1] “Reactive” optical sensor for Hg2+ and its application in environmental aqueous media and biological systems
    Zhi Chen
    Jiayun Chen
    Dong Pan
    Hongwei Li
    Yunhui Yao
    Zu Lyu
    Liting Yang
    Li-Jun Ma
    Analytical and Bioanalytical Chemistry, 2017, 409 : 2429 - 2435
  • [2] Development of an Aptamer Based Luminescent Optical Fiber Sensor for the Continuous Monitoring of Hg2+ in Aqueous Media
    De Acha, Nerea
    Elosua, Cesar
    Arregui, Francisco J.
    SENSORS, 2020, 20 (08)
  • [3] The detection of Hg2+ by cyanobacteria in aqueous media
    Suresh, Moorthy
    Mishra, Sanjiv K.
    Mishra, Sandhya
    Das, Amitava
    CHEMICAL COMMUNICATIONS, 2009, (18) : 2496 - 2498
  • [4] Highly selective chemosensor for the sensitive detection of Hg2+ in aqueous media and its cell imaging application
    Chen, Jin
    Tao, Jing
    Yu, Hai-Feng
    Ma, Cui-Ping
    Tan, Feng
    Wang, Xiao-Chun
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 296
  • [5] A turn-on chemosensor for Hg2+ in aqueous media and its application in "MCT" imaging in living cells
    Xi, Pinxian
    Huang, Liang
    Xie, Guoqiang
    Chen, Fengjuan
    Xu, Zhihong
    Bai, Decheng
    Zeng, Zhengzhi
    DALTON TRANSACTIONS, 2011, 40 (24) : 6382 - 6384
  • [6] Rhodamine Based Fluorescent Chemosensors for Hg2+ and its Biological Application
    Choi, Ji Young
    Kim, Wantae
    Yoon, Juyoung
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2012, 33 (07): : 2359 - 2364
  • [7] Synthesis and Characterization of a Rapid and Highly Selective Fluorescent Hg2+ Sensor in Aqueous Media
    Li, Xiao Liang
    He, Yong Wu
    Yang, Sung Ik
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2011, 32 (01): : 338 - 340
  • [8] Fluorescent sensor for Hg2+ detection in aqueous solution
    Han, Aixia
    Liu, Xiaohui
    Prestwich, Glenn D.
    Zang, Ling
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 198 : 274 - 277
  • [9] Development of a Nile-Blue Based Chemodosimeter for Hg2+ in Aqueous Solution and its Application in Biological Imaging
    Hu, Mingming
    Yin, Jianhua
    Li, Yahong
    Zhao, Xiaofang
    JOURNAL OF FLUORESCENCE, 2015, 25 (02) : 403 - 408
  • [10] Environmental application of mineral sulfides for removal of gas-phase Hg(0) and aqueous Hg2+
    Martellaro, PJ
    Moore, GA
    Peterson, ES
    Abbott, EH
    Gorenbain, AE
    SEPARATION SCIENCE AND TECHNOLOGY, 2001, 36 (5-6) : 1183 - 1196