Virtual patient 3D dose reconstruction using in air EPID measurements and a back-projection algorithm for IMRT and VMAT treatments

被引:35
|
作者
Olaciregui-Ruiz, Igor [1 ]
Rozendaal, Roel [1 ]
van Oers, Rene F. M. [1 ]
Mijnheer, Ben [1 ]
Mans, Anton [1 ]
机构
[1] Netherlands Canc Inst, Dept Radiat Oncol, Plesmanlaan 121, NL-1066 CX Amsterdam, Netherlands
关键词
EPID dosimetry; Pre-treatment; In vivo; Verification; IMRT; VMAT; PRETREATMENT VERIFICATION; PASSING RATES; GAMMA INDEX; DOSIMETRY; QA; THERAPY;
D O I
10.1016/j.ejmp.2017.04.016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: At our institute, a transit back-projection algorithm is used clinically to reconstruct in vivo patient and in phantom 3D dose distributions using EPID measurements behind a patient or a polystyrene slab phantom, respectively. In this study, an extension to this algorithm is presented whereby in air EPID measurements are used in combination with CT data to reconstruct 'virtual' 3D dose distributions. By combining virtual and in vivo patient verification data for the same treatment, patient-related errors can be separated from machine, planning and model errors. Methods and materials: The virtual back-projection algorithm is described and verified against the transit algorithm with measurements made behind a slab phantom, against dose measurements made with an ionization chamber and with the OCTAVIUS 4D system, as well as against TPS patient data. Virtual and in vivo patient dose verification results are also compared. Results: Virtual dose reconstructions agree within 1% with ionization chamber measurements. The average c-pass rate values (3% global dose/3 mm) in the 3D dose comparison with the OCTAVIUS 4D system and the TPS patient data are 98.5 +/- 1.9%(1SD) and 97.1 +/- 2.9%(1SD), respectively. For virtual patient dose reconstructions, the differences with the TPS in median dose to the PTV remain within 4%. Conclusions: Virtual patient dose reconstruction makes pre-treatment verification based on deviations of DVH parameters feasible and eliminates the need for phantom positioning and re-planning. Virtual patient dose reconstructions have additional value in the inspection of in vivo deviations, particularly in situations where CBCT data is not available (or not conclusive). (C) 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:49 / 57
页数:9
相关论文
共 50 条
  • [1] 3D dose reconstruction in the patient from VARIAN EPID images for IMRT and VMAT treatments
    Younan, F.
    Mazurier, J.
    Franceries, X.
    Franck, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S932 - S932
  • [2] 3D Absorbed Dose Reconstructed in the Patient from EPID Images for IMRT and VMAT Treatments
    Younan, Fouad
    Mazurier, Jocelyne
    Chatrie, Frederic
    Barbeiro, Ana Rita
    Berry, Isabelle
    Franck, Denis
    Franceries, Xavier
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3, 2019, 68 (03): : 605 - 609
  • [3] Validation of a method for in vivo 3D dose reconstruction for IMRT and VMAT treatments using on-treatment EPID images and a model-based forward-calculation algorithm
    Van Uytven, Eric
    Van Beek, Timothy
    McCowan, Peter M.
    Chytyk-Praznik, Krista
    Greer, Peter B.
    McCurdy, Boyd M. C.
    [J]. MEDICAL PHYSICS, 2015, 42 (12) : 6945 - 6954
  • [4] 3D patient dose reconstruction for clinical evaluation of IMRT pretreatment verification with an EPID
    van Zijtveld, M
    Dirkx, M
    de Boer, H
    Heijmen, B
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S42 - S42
  • [5] 3D Dose Reconstruction using EPID Images Acquired during IMRT Treatment
    Zhao, B.
    Yang, Y.
    Li, T.
    Heron, D. E.
    Huq, M. S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S633 - S634
  • [6] Quantitative Evaluation of 3D Reconstruction Using Filtered Back-Projection on XCAT Phantom
    Farhat, Jumana
    Alatoom, Aseel
    Dhou, Salam
    [J]. 2019 3RD INTERNATIONAL CONFERENCE ON COMMUNICATIONS, SIGNAL PROCESSING, AND THEIR APPLICATIONS (ICCSPA), 2019,
  • [7] A simple backprojection algorithm for 3D in vivo EPID dosimetry of IMRT treatments
    Wendling, Markus
    McDermott, Leah N.
    Mans, Anton
    Sonke, Jan-Jakob
    van Herk, Marcel
    Mijnheer, Ben J.
    [J]. MEDICAL PHYSICS, 2009, 36 (07) : 3310 - 3321
  • [8] 3D dose reconstruction for clinical evaluation of IMRT pretreatment verification with an EPID
    van Zijtveld, Mathilda
    Dirkx, Maarten L. P.
    de Boer, Hans C. J.
    Heijmen, Ben J. M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 82 (02) : 201 - 207
  • [9] A Novel EPID-Based 3D Dose Reconstruction for IMRT QA
    Alhazmi, A.
    Gianoli, C.
    Neppl, S.
    Veloza, S.
    Martins, J.
    Podesta, M.
    Verhaegen, F.
    Reiner, M.
    Belka, C.
    Parodi, K.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2887 - 2887
  • [10] Sensitivity analysis of EPID-based 3D dose reconstruction for VMAT QA
    Alhazmi, A.
    Gianoli, C.
    Neppl, S.
    Martins, J.
    Veloza, S.
    Podesta, M.
    Verhaegen, F.
    Reiner, M.
    Belka, C.
    Parodi, K.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S960 - S961