Detection of fine iron particles in high speed scrolled wire by high-T-c SQUID

被引:0
|
作者
Itozaki, H
Nagaishi, T
Toyoda, H
Kugai, H
机构
关键词
high-T-c; SQUID; large washer; flux transformer; nondestructive evaluation;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High-T-c SQUID was applied to the detection of magnetized fine particle moving at high speed. Two types of SQUIDs were used. One was a large washer type and the other was a flux transformer type. Their Josephson junctions were step edge type. The iron particle was attached on a nylon wire and scanned under the SQUID. High-T-c SQUID detected an iron particle of 50 mu m diameter running at 800 m/min. It was shown that the magnetic field measured by the SQUID was proportional to the volumer of the particle and is inversely proportional to the distance between the SQUID and the particle. This technique using high-T-c SQUID is hopeful not only to wire production line but also for the processing of food and medicine, etc.
引用
收藏
页码:1247 / 1251
页数:5
相关论文
共 50 条
  • [1] Detection of moving fine iron particles by high-Tc SQUID
    Nagaishi, T
    Toyoda, H
    Kugai, H
    Itozaki, H
    APPLIED SUPERCONDUCTIVITY, 1998, 6 (7-9) : 303 - 308
  • [2] Detection of moving fine iron particles by high-Tc SQUID
    Nagaishi, T.
    Toyoda, H.
    Kugai, H.
    Itozaki, H.
    Applied Superconductivity, 1998, 6 (07): : 303 - 308
  • [3] NDT of high speed fine particles by high Tc SQUID
    Nagaishi, T
    Kugai, H
    Toyoda, H
    Itozaki, H
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1997, 7 (02) : 2886 - 2889
  • [4] High-T-c SQUID magnetometers for biomagnetic measurements
    David, B
    Grundler, D
    Krey, S
    Doormann, V
    Eckart, R
    Krumme, JP
    Rabe, G
    Doessel, O
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1996, 9 (4A): : A96 - A99
  • [5] Heart monitoring with high-T-c dc SQUID
    Weidl, R
    Brabetz, S
    Klemm, F
    Dorrer, L
    Schmidl, F
    Seidel, P
    CRYOGENICS, 1997, 37 (10) : 691 - 693
  • [6] High-T-c SQUID microscope for room temperature samples
    Lee, TS
    Chemla, YR
    Dantsker, E
    Clarke, J
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1997, 7 (02) : 3147 - 3150
  • [7] Pulse tube refrigerator for high-T-C squid operation
    Thummes, G
    Landgraf, R
    Giebeler, F
    Muck, M
    Heiden, C
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 41, PTS A AND B, 1996, : 1463 - 1470
  • [8] HIGH-FREQUENCY MAGNETIC MICROSCOPY USING A HIGH-T-C SQUID
    BLACK, RC
    WELLSTOOD, FC
    DANTSKER, E
    MIKLICH, AH
    KOELLE, D
    LUDWIG, F
    CLARKE, J
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1995, 5 (02) : 2137 - 2141
  • [9] Design and analysis of high-T-c SQUID current amplifiers
    Hildebrandt, G
    Uhlmann, HF
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1997, 7 (02) : 3481 - 3484
  • [10] DOES PROGRAM ON THE APPLICATION OF HIGH-T-C WIRE
    HAWSEY, R
    DALEY, J
    JOM-JOURNAL OF THE MINERALS METALS & MATERIALS SOCIETY, 1995, 47 (08): : 56 - 58