Exergy analysis of a 1000 MW single reheat advanced supercritical carbon dioxide coal-fired partial flow power plant

被引:35
|
作者
Zhou, Jing [1 ]
Ling, Peng [1 ]
Su, Sheng [1 ]
Xu, Jun [1 ]
Xu, Kai [1 ]
Wang, Yi [1 ]
Hu, Song [1 ]
Zhu, Meng [1 ]
Xiang, Jun [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, State Key Lab Coal Combust, Wuhan 430074, Hubei, Peoples R China
基金
国家重点研发计划; 美国国家科学基金会;
关键词
Supercritical carbon dioxide Brayton cycle; Coal-fired power plant; Waste heat utilization; Exergy analysis; CO2; POWER; PERFORMANCE; CAPTURE; DESIGN; CYCLE; COMBUSTION; ENERGY; SYSTEM; HEAT;
D O I
10.1016/j.fuel.2019.115777
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A comprehensive energy and exergy analysis for traditional steam power plant (TSPP) and supercritical carbon dioxide (S-CO2) power plants is constructed. The exergy distribution analysis and optimization methods of the Cycle-Internal-Split-Flow (CISF) and Connected-Top-Bottom-Cycle (CTBC) units of the S-CO2 partial flow power plant are conducted. The energy analysis reveals that the S-CO2 power plant (SCO2PP) has the remarkable characteristics of higher average endothermic temperature and overall power plant energy efficiency compared with traditional steam power plant. The results show that the exergy loss of the heat exchange surface of SCO2PP is obviously lower than that of TSPP. And the exergy loss of the heat exchange surface and S-CO2 Brayton cycle has more remarkable effect on the overall power plant exergy efficiency compared with other subsystems. Besides the main findings are the following: the exergy loss of FGC and HTR takes up considerably high percentages in CISF unit and connected-bottom-cycle turbine (CBT) has relatively lower exergy efficiency in CTBC unit. The innovative S-CO2 boiler layouts including adjacent double flue gas cooler (ADFGC) and staggered double flue gas cooler (SDFGC) layouts are presents in the CISF and CTBC units, respectively. From the perspective of system performance and layout complexity, the 1000 MW single reheat S-CO2 partial flow coal-fired power plant using the CISF and the ADFGC boiler layouts offers more interesting advantages: the 48.22% overall plant exergy efficiency (LHV) and simpler system configuration.
引用
下载
收藏
页数:10
相关论文
共 50 条
  • [1] Exergy analysis of a 1000 MW single reheat supercritical CO2 Brayton cycle coal-fired power plant
    Zhou, Jing
    Zhang, Chenhao
    Su, Sheng
    Wang, Yi
    Hu, Song
    Liu, Liang
    Ling, Peng
    Zhong, Wenqi
    Xiang, Jun
    ENERGY CONVERSION AND MANAGEMENT, 2018, 173 : 348 - 358
  • [2] Application of exergy analysis in understanding the performance of a coal-fired steam power plant (120 MW) with single reheat and regenerative configuration
    Arpit, Sankalp
    Kumar, Prabhakar
    Das, Prasanta Kumar
    Dash, Sukanta Kumar
    JOURNAL OF THERMAL ENGINEERING, 2023, 9 (02): : 497 - 509
  • [3] Exergy and exergo-environmental analysis of a 660 MW supercritical coal-fired power plant
    Keval Chandrakant Nikam
    Ravinder Kumar
    Ravindra Jilte
    Journal of Thermal Analysis and Calorimetry, 2021, 145 : 1005 - 1018
  • [4] Exergy and exergo-environmental analysis of a 660 MW supercritical coal-fired power plant
    Nikam, Keval Chandrakant
    Kumar, Ravinder
    Jilte, Ravindra
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 145 (03) : 1005 - 1018
  • [5] Exergy Analysis of 300MW Coal-Fired Power Plant
    Li, Yong
    Liu, Lei
    2012 INTERNATIONAL CONFERENCE ON FUTURE ELECTRICAL POWER AND ENERGY SYSTEM, PT A, 2012, 17 : 926 - 932
  • [6] Exergy analysis of a 1000 MW double reheat ultra-supercritical power plant
    Si, Ningning
    Zhao, Zhigang
    Su, Sheng
    Han, Pengshuai
    Sun, Zhijun
    Xu, Jun
    Cui, Xiaoning
    Hu, Song
    Wang, Yi
    Jiang, Long
    Zhou, Yingbiao
    Chen, Gang
    Xiang, Jun
    ENERGY CONVERSION AND MANAGEMENT, 2017, 147 : 155 - 165
  • [7] Key issues and innovative double-tangential circular boiler configurations for the 1000 MW coal-fired supercritical carbon dioxide power plant
    Zhou, Jing
    Zhu, Meng
    Xu, Kai
    Su, Sheng
    Tang, Yifang
    Hu, Song
    Wang, Yi
    Xu, Jun
    He, Limo
    Xiang, Jun
    ENERGY, 2020, 199 (199)
  • [8] Exergy analysis of the turbine system in a 1000 MW double reheat ultra-supercritical power plant
    Zhao, Zhigang
    Su, Sheng
    Si, Ningning
    Hu, Song
    Wang, Yi
    Xu, Jun
    Jiang, Long
    Chen, Gang
    Xiang, Jun
    ENERGY, 2017, 119 : 540 - 548
  • [9] Techno-economic analysis of supercritical carbon dioxide cycle integrated with coal-fired power plant
    Thanganadar, Dhinesh
    Asfand, Faisal
    Patchigolla, Kumar
    Turner, Peter
    ENERGY CONVERSION AND MANAGEMENT, 2021, 242
  • [10] Research and Development of Supercritical Carbon Dioxide Coal-Fired Power Systems
    Li, Zhaozhi
    Liu, Xuejiao
    Shao, Yingjuan
    Zhong, Wenqi
    JOURNAL OF THERMAL SCIENCE, 2020, 29 (03) : 546 - 575