Design and implementation of seismic data acquisition system using PC/104

被引:2
|
作者
Daryono, L. R. [1 ]
Rahmadi, A. [2 ]
Suyanto, I. [2 ]
Suryanto, W. [2 ]
机构
[1] Hokkaido Univ, Grad Sch Engn, Div Sustainable Resources, Lab Biotechnol Resources, Sapporo, Hokkaido, Japan
[2] Univ Gadjah Mada, Fac Math & Sci, Geophys Subdepart, Yogyakarta, Indonesia
关键词
PC/104; Analog digital converter; Seismic data acquisition system;
D O I
10.1007/s42452-019-1038-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The seismic data acquisition system from analog to digital data converter has been integrated to develop acquisition device. Contrary to the digitizers currently in use, seismic data acquisition using PC/104, or industrial personal computer, turned out to be able to produce a less expensive digitizer (analog to digital converter) proven able to overcome issues of portability, efficiency, and durability. PC/104 used in this study was Arbor production with the EmCORE n-511 serial number within operating system, and the programming languages are DOS 6.02 and C, respectively. This research resulted in a design of a prototyping device based on PC/104 and created a program to record seismic data. The program was compiled in the Microsoft Windows XP operating system environment using Borland C 5.02 software. The input range of the data acquisition system that has been tested is +/- 10 V. The performance test results show a resolution of +/- 0.915 mV, a linearity of 0.2% full-scale reading, instrument work noise is +/- 1.2 mV with a maximum frequency distortion of 2%. The instrument performs well at a rate of 10 Hz to 5000 Hz, but the software has a limited capacity of only 1000 Hz. From the results of a comparative test with Digitizer Guralp Type CGM-DM16R8, the value of the RMS error is 4.64%.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Design and implementation of seismic data acquisition system using PC/104
    L. R. Daryono
    A. Rahmadi
    I. Suyanto
    W. Suryanto
    [J]. SN Applied Sciences, 2019, 1
  • [2] Design and Implementation of Seismic Data Acquisition System using MEMS Accelerometer
    [J]. Choi, H. (hchoi@deu.ac.kr), 1600, Korean Institute of Electrical Engineers (61):
  • [3] Design of seismic data acquisition system
    Li Ming
    Yuan Zi
    Jiang Chunlan
    [J]. 2010 IEEE 10TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING PROCEEDINGS (ICSP2010), VOLS I-III, 2010, : 2580 - +
  • [4] Design and implementation of a data acquisition system
    Huo, H
    [J]. ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 781 - 784
  • [5] A Synchronous Data Acquisition System Based-on PC104-plus
    Wang Xinhua
    Zhang Xianghong
    [J]. ISTM/2009: 8TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, 2009, : 3190 - 3193
  • [6] Design and implementation of a wireless data acquisition system
    Nagel, JE
    Walker, CF
    [J]. IEEE REGION 5 2003 ANNUAL TECHNICAL CONFERENCE, CONFERENCE RECORD, 2003, : 7 - 10
  • [7] Design and Implementation of Data Acquisition System for AETA
    Yang, Xingwen
    Yong, Shanshan
    Wang, Xin'an
    Zhou, Kangsheng
    Jin, Xiuru
    [J]. Beijing Daxue Xuebao (Ziran Kexue Ban)/Acta Scientiarum Naturalium Universitatis Pekinensis, 2020, 56 (04): : 600 - 606
  • [8] The design and implementation of a data acquisition and control system using fieldbus technologies
    Turner, JR
    Jennings, AD
    Prickett, PW
    Grosvenor, RI
    [J]. CONDITION MONITORING AND DIAGNOSTIC ENGINEERING MANAGEMENT, 2001, : 391 - 398
  • [9] Design and implementation of a PC-based data acquisition system for measuring ECG and respiratory signals
    Suominen, K
    [J]. INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1997, 14 (04): : 225 - 230
  • [10] Design and Implementation of Real Time Data Acquisition System using Reconfigurable SoC
    Devi, Dharmavaram Asha
    Savithri, Tirumala Satya
    Sugun, Sai L.
    [J]. INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2020, 11 (09) : 325 - 331