Research on Pressure Pulsation Characteristics of Gerotor Pump for Active Vibration Damping System

被引:7
|
作者
Cao, Wenbin [1 ]
Liu, Yinshui [1 ,2 ]
Dong, Jie [1 ]
Niu, Zhuang [3 ]
Shi, Youcheng [2 ]
机构
[1] Lanzhou Univ Technol, Sch Energy & Power Engn, Lanzhou 730050, Gansu, Peoples R China
[2] Huazhong Univ Sci & Technol, Sch Mech Sci & Engn, Wuhan 430074, Hubei, Peoples R China
[3] Huazhong Univ Sci & Technol, Wuxi Res Inst, Wuxi 214174, Jiangsu, Peoples R China
来源
IEEE ACCESS | 2019年 / 7卷
基金
中国国家自然科学基金;
关键词
Active vibration damping system; gerotor pump; low pulsation; pulsation buffer; ROTOR PROFILE; FLOW-RATE; DESIGN; PERFORMANCE; CHAMBER; GEARS; PORT;
D O I
10.1109/ACCESS.2019.2936489
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
High response, stable operation, small volume active vibration damping system and other intelligent hydraulic equipment have become the inevitable trend of future development. A compact low-pulsation gerotor pump is designed to meet these requirements, the theoretical flow pulsation of 8/9 tooth gerotor pump is analysed, and its pressure pulsation characteristics are also studied in this paper. The combined pulsation buffer is placed at the bottom valve plate high-pressure port of pumps. High-pressure oil passes through the honeycomb damping hole and enters the diaphragm volume chamber of the accumulator to form a combined pulsation buffer. Considering the effect of the pulsation buffer structure to reduce flow pulsation at different speeds, a test bench for high-speed gerotor pump pulsation characteristics is built, and the pressure pulsation of the gerotor pump with and without pulsation buffer is analysed at different speeds. Results show that the pressure pulsation frequency increases with pump speed. When the speed reaches 5500 r/min, 8/9 tooth gerotor pump without pulsation buffer outlet pressure pulsation reached 13.797% and that with pulsation buffer outlet pressure pulsation decreased to 9.871%, showing a 28.46% decline rate. At pump rotation speeds are 1500 r/min and 2500 r/min, the pulsation reduction ratios are 37.78% and 35.36%. The pressure pulsation of the gerotor pump can be evidently reduced by designing a combined pulsation buffer in this paper. Therefore, this high-speed and low-pulsation gerotor pump is suitable for active vibration damping system and other intelligent hydraulic equipment.
引用
收藏
页码:116567 / 116577
页数:11
相关论文
共 50 条
  • [1] Effects of materials on the tribological properties and the noise of gerotor pump used in active vibration damping system
    Cao, Wenbin
    Liu, Yinshui
    Bai, Guixiang
    Dong, Jie
    Dong, Qingzhen
    [J]. JOURNAL OF ADVANCED MECHANICAL DESIGN SYSTEMS AND MANUFACTURING, 2021, 15 (06):
  • [2] Design of port plate in gerotor pump for reduction of pressure pulsation
    Sang-Yeol Kim
    Yun-Joo Nam
    Myeong-Kwan Park
    [J]. Journal of Mechanical Science and Technology, 2006, 20 : 1626 - 1637
  • [3] Design of port plate in gerotor pump for reduction of pressure pulsation
    Kim, Sang-Yeol
    Nam, Yun-Joo
    Park, Myeong-Kwan
    [J]. JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2006, 20 (10) : 1626 - 1637
  • [4] Design and experimental verification of a port plate in a gerotor pump to reduce pressure pulsation
    Hee-Jee Sung
    Hyung-Ki Min
    Yun-Joo Nam
    Myung-Kwan Park
    [J]. Journal of Mechanical Science and Technology, 2018, 32 : 671 - 678
  • [5] The Research on Pulsation of Pump Pressure in Water Mist System
    Xu Zhenyu
    Miao Xuhong
    Zuo Hai
    [J]. 12TH INTERNATIONAL CONFERENCE ON COMBUSTION & ENERGY UTILISATION, 2015, 66 : 73 - 76
  • [6] Design and experimental verification of a port plate in a gerotor pump to reduce pressure pulsation
    Sung, Hee-Jee
    Min, Hyung-Ki
    Nam, Yun-Joo
    Park, Myung-Kwan
    [J]. JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2018, 32 (02) : 671 - 678
  • [7] PRESSURE PULSATION IN A CENTRIFUGAL PUMP-PIPING SYSTEM - (EXPERIMENTAL EXAMINATION OF CHARACTERISTICS OF PRESSURE PULSATION)
    GOTO, M
    [J]. JSME INTERNATIONAL JOURNAL SERIES II-FLUIDS ENGINEERING HEAT TRANSFER POWER COMBUSTION THERMOPHYSICAL PROPERTIES, 1990, 33 (01): : 106 - 113
  • [8] Research on pressure pulsation characteristics of a reactor coolant pump in hump region
    Huang, Song
    Song, Yu
    Yin, Junlian
    Xu, Rui
    Wang, Dezhong
    [J]. ANNALS OF NUCLEAR ENERGY, 2022, 178
  • [9] Experimental research on pressure pulsation and cavitation characteristics of centrifugal fire pump
    Liu, Houlin
    Hu, Jianbin
    He, Zhoufeng
    Wang, Kai
    Lu, Xin
    [J]. JOURNAL OF LOW FREQUENCY NOISE VIBRATION AND ACTIVE CONTROL, 2023, 42 (03) : 1339 - 1349
  • [10] RESEARCH ON THE VIBRATION REDUCTION CHARACTERISTICS OF ROLLING MILL ROLL SYSTEM WITH ACTIVE AND PASSIVE DAMPING SHOCK ABSORBERS
    Xu, Huidong
    Wang, Yiping
    He, Dongping
    Zhou, Biliu
    Zhang, Wei
    [J]. Lixue Xuebao/Chinese Journal of Theoretical and Applied Mechanics, 2024, 56 (09): : 2713 - 2730