Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging and Fusion Guided Targeted Biopsy Evaluated by Transperineal Template Saturation Prostate Biopsy for the Detection and Characterization of Prostate Cancer

被引:41
|
作者
Mortezavi, Ashkan [1 ]
Marzendorfer, Olivia [1 ]
Donati, Olivio F. [2 ]
Rizzi, Gianluca [1 ]
Rupp, Niels J. [3 ]
Wettstein, Marian S. [1 ,4 ]
Gross, Oliver [1 ]
Sulser, Tullio [1 ]
Hermanns, Thomas [1 ]
Eberli, Daniel [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Dept Urol, Zurich, Switzerland
[2] Univ Zurich, Univ Hosp Zurich, Inst Diagnost & Intervent Radiol, Zurich, Switzerland
[3] Univ Zurich, Univ Hosp Zurich, Inst Surg Pathol, Zurich, Switzerland
[4] Univ Toronto, Inst Hlth Policy Management & Evaluat, Toronto, ON, Canada
来源
JOURNAL OF UROLOGY | 2018年 / 200卷 / 02期
关键词
prostatic neoplasms; magnetic resonance imaging; image-guided biopsy; endoscopic ultrasound-guided fine needle aspiration; diagnostic imaging; TRANSRECTAL ULTRASOUND FUSION; DATA SYSTEM; MRI;
D O I
10.1016/j.juro.2018.02.067
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We evaluated the diagnostic accuracy of multiparametric magnetic resonance imaging and multiparametric magnetic resonance imaging/transrectal ultrasound fusion guided targeted biopsy against that of transperineal template saturation prostate biopsy to detect prostate cancer. Materials and Methods: We retrospectively analyzed the records of 415 men who consecutively presented for prostate biopsy between November 2014 and September 2016 at our tertiary care center. Multiparametric magnetic resonance imaging was performed using a 3 Tesla device without an endorectal coil, followed by transperineal template saturation prostate biopsy with the BiopSee (R) fusion system. Additional fusion guided targeted biopsy was done in men with a suspicious lesion on multiparametric magnetic resonance imaging, defined as Likert score 3 to 5. Any Gleason pattern 4 or greater was defined as clinically significant prostate cancer. The detection rates of multiparametric magnetic resonance imaging and fusion guided targeted biopsy were compared with the detection rate of transperineal template saturation prostate biopsy using the McNemar test. Results: We obtained a median of 40 (range 30 to 55) and 3 (range 2 to 4) transperineal template saturation prostate biopsy and fusion guided targeted biopsy cores, respectively. Of the 124 patients (29.9%) without a suspicious lesion on multiparametric magnetic resonance imaging 32 (25.8%) were found to have clinically significant prostate cancer on transperineal template saturation prostate biopsy. Of the 291 patients (70.1%) with a Likert score of 3 to 5 clinically significant prostate cancer was detected in 129 (44.3%) by multiparametric magnetic resonance imaging fusion guided targeted biopsy, in 176 (60.5%) by transperineal template saturation prostate biopsy and in 187 (64.3%) by the combined approach. Overall 58 cases (19.9%) of clinically significant prostate cancer would have been missed if fusion guided targeted biopsy had been performed exclusively. The sensitivity of multiparametric magnetic resonance imaging and fusion guided targeted biopsy for clinically significant prostate cancer was 84.6% and 56.7% with a negative likelihood ratio of 0.35 and 0.46, respectively. Conclusions: Multiparametric magnetic resonance imaging alone should not be performed as a triage test due to a substantial number of false-negative cases with clinically significant prostate cancer. Systematic biopsy outperformed fusion guided targeted biopsy. Therefore, it will remain crucial in the diagnostic pathway of prostate cancer.
引用
收藏
页码:309 / 317
页数:9
相关论文
共 50 条
  • [1] Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging and Fusion Guided Targeted Biopsy Evaluated by Transperineal Template Saturation Prostate Biopsy for the Detection and Characterization of Prostate Cancer EDITORIAL COMMENT
    Dominguez-Escrig, Jose L.
    JOURNAL OF UROLOGY, 2018, 200 (02): : 317 - 318
  • [2] Diagnostic accuracy of magnetic resonance-guided prostate biopsy and template-guided transperineal saturation biopsy
    Zhou, Yi
    Zhou, Zhien
    Li, Qianyue
    Xu, Yinyan
    Sun, Hao
    Xiao, Yu
    Liang, Zhiyong
    Yan, Weigang
    Ji, Zhigang
    Li, Hanzhong
    MEDICINE, 2018, 97 (38)
  • [3] Transperineal Multiparametric Magnetic Resonance Imaging-Ultrasound Fusion Targeted Prostate Biopsy Combined with Standard Template Improves Prostate Cancer Detection
    Kim, Michelle M.
    Wu, Shulin
    Lin, Sharron X.
    Crotty, Rory K.
    Harisinghani, Mukesh
    Feldman, Adam S.
    Wu, Chin-Lee
    Dahl, Douglas M.
    JOURNAL OF UROLOGY, 2022, 207 (01): : 86 - 92
  • [5] Transperineal Magnetic Resonance Image Targeted Prostate Biopsy Versus Transperineal Template Prostate Biopsy in the Detection of Clinically Significant Prostate Cancer
    Labanaris, Apostolos P.
    JOURNAL OF UROLOGY, 2013, 189 (03): : 866 - 866
  • [6] Detection of Clinically Significant Prostate Cancer by Transperineal Multiparametric Magnetic Resonance Imaging-Ultrasound Fusion Targeted Prostate Biopsy in Smaller Prostate
    Wu, Shulin
    Dahl, Douglas
    Kim, Michelle
    Lin, Sharron
    Crotty, Rory
    Cornejo, Kristine
    Harisinghani, Mukesh
    Feldman, Adam
    Wu, Chin-Lee
    LABORATORY INVESTIGATION, 2022, 102 (SUPPL 1) : 697 - 698
  • [7] Detection of Clinically Significant Prostate Cancer by Transperineal Multiparametric Magnetic Resonance Imaging-Ultrasound Fusion Targeted Prostate Biopsy in Smaller Prostate
    Wu, Shulin
    Dahl, Douglas
    Kim, Michelle
    Lin, Sharron
    Crotty, Rory
    Cornejo, Kristine
    Harisinghani, Mukesh
    Feldman, Adam
    Wu, Chin-Lee
    MODERN PATHOLOGY, 2022, 35 (SUPPL 2) : 697 - 698
  • [8] The diagnostic accuracy of multiparametric magnetic resonance imaging before biopsy in the detection of prostate cancer
    Otti, Vanessa C.
    Miller, Catherine
    Powell, Roy J.
    Thomas, Richard M.
    McGrath, John S.
    BJU INTERNATIONAL, 2019, 123 (01) : 82 - 90
  • [9] Re: Transperineal Magnetic Resonance Image Targeted Prostate Biopsy Versus Transperineal Template Prostate Biopsy in the Detection of Clinically Significant Prostate Cancer
    Ravery, Vincent
    EUROPEAN UROLOGY, 2013, 64 (02) : 337 - 337
  • [10] Comparative Analysis of Transperineal Template Saturation Prostate Biopsy Versus Magnetic Resonance Imaging Targeted Biopsy with Magnetic Resonance Imaging-Ultrasound Fusion Guidance
    Radtke, Jan P.
    Kuru, Timur H.
    Boxler, Silvan
    Alt, Celine D.
    Popeneciu, Ionel V.
    Huettenbrink, Clemens
    Klein, Tilman
    Steinemann, Sarah
    Bergstraesser, Claudia
    Roethke, Matthias
    Roth, Wilfried
    Schlemmer, Heinz-Peter
    Hohenfellner, Markus
    Hadaschik, Boris A.
    JOURNAL OF UROLOGY, 2015, 193 (01): : 87 - 94