Operative and hardware complications of deep brain stimulation for movement disorders

被引:51
|
作者
Paluzzi, A.
Belli, A.
Bain, P.
Liu, X.
Aziz, T. M.
机构
[1] Newcastle Gen Hosp, Div Clin Neurosci, Newcastle Upon Tyne NE4 6BE, Tyne & Wear, England
[2] Univ Southampton, Div Clin Neurosci, Southampton, Hants, England
[3] Charing Cross Hosp, W London Neurosci Ctr, London, England
关键词
complications; deep brain stimulation; follow-up; movement disorders;
D O I
10.1080/02688690601012175
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The objective of this investigation was to present the operative and hardware complications encountered during follow-up of patients with in situ deep brain stimulators. The study took the form of a retrospective chart review on a series of consecutive patients who were treated successfully with insertion of deep brain stimulators at a single centre by a single surgeon between 1999 and 2005. During the study period, a total of 60 patients underwent 96 procedures for implantation of unilateral or bilateral DBS electrodes. The mean follow-up period was 43.7 months ( range 6 - 78 months) from the time of the first procedure. No patients were lost to follow-up or died. Eighteen patients (30%) developed 28 adverse events, requiring 28 electrodes to be replaced. Seven patients developed two adverse events and two patients developed three adverse events. The rate of adverse events per electrode-year was 8%. We observed a higher proportion of early complications ( 56 months postoperatively) in patients with Parkinson's disease, while dystonic patients had more late complications ( 46 months postoperatively) and no early complications. Thirty per cent of our patients developed an adverse event that could potentially lead to revision of the implanted hardware. In patients with Parkinson's disease most of the complications tend to occur during the first 6 months postoperatively, while in dystonic patients most occur between 12 and 24 months postoperatively.
引用
收藏
页码:290 / 295
页数:6
相关论文
共 50 条
  • [1] Deep brain stimulation system: Hardware related complications in patients with movement disorders
    Carvallo, J. F. Baizabal
    Mostile, G.
    Almaguer, M.
    Davidson, A.
    Simpson, R.
    Jankovic, J.
    MOVEMENT DISORDERS, 2011, 26 : S84 - S85
  • [2] Deep Brain Stimulation Hardware Complications in Patients with Movement Disorders: Risk Factors and Clinical Correlations
    Carvallo, Jose Fidel Baizabal
    Mostile, Giovanni
    Almaguer, Mike
    Davidson, Anthony
    Simpson, Richard
    Jankovic, Joseph
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2012, 90 (05) : 300 - 306
  • [3] Deep Brain Stimulation System Revision, and Hardware Related Complications in 512 Patients with Movement Disorders
    Carvallo, Jose F. Baizabal
    Mostile, Giovanni
    Simpson, Richard
    Almaguer, Michael
    Davidson, Anthony
    Jankovic, Joseph
    NEUROLOGY, 2011, 76 (09) : A450 - A450
  • [4] Complications of hardware in deep brain stimulation
    Gelabert-Gonzalez, Miguel
    Rico-Cotelo, Maria
    Luis Relova-Quinteiro, Jose
    Castro-Garcia, Alfonso
    REVISTA DE NEUROLOGIA, 2014, 59 (08) : 384 - 384
  • [5] Hardware complications with deep brain stimulation devices
    Germanwala, A
    Kondziolka, D
    Whiting, D
    Oh, MY
    NEUROSURGERY, 2002, 51 (02) : 586 - 587
  • [6] Deep Brain Stimulation for Movement Disorders
    Larson, Paul S.
    NEUROTHERAPEUTICS, 2014, 11 (03) : 465 - 474
  • [7] Deep brain stimulation in movement disorders
    Tamas, G.
    Takats, A.
    Bereczki, D.
    Eross, L.
    ACTA PHYSIOLOGICA HUNGARICA, 2010, 97 (01) : 86 - 86
  • [8] Deep brain stimulation for movement disorders
    Deuschl, G
    Volkmann, J
    Krack, P
    MOVEMENT DISORDERS, 2002, 17 : S1 - S1
  • [9] Deep brain stimulation for movement disorders
    Pizzolato, Gilberto
    Mandat, Tomasz
    FRONTIERS IN INTEGRATIVE NEUROSCIENCE, 2012, 6
  • [10] Deep brain stimulation for movement disorders
    Steigerwald, F.
    Volkmann, J.
    NERVENARZT, 2012, 83 (08): : 988 - +