MRI of the inner ear -: Comparison of axial T2-weighted, three-dimensional turbo spin-echo images, maximum-intensity projections, and volume rendering

被引:15
|
作者
Krombach, GA [1 ]
Schmitz-Rode, T [1 ]
Tacke, J [1 ]
Glowinski, A [1 ]
Nolte-Ernsting, CC [1 ]
Günther, RW [1 ]
机构
[1] Univ Technol RWTH Aachen, Dept Diagnost Radiol, D-52074 Aachen, Germany
关键词
ear anatomy; labyrinth; image processing; computer-assisted; MR imaging;
D O I
10.1097/00004424-200006000-00001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. TO compare the ability of axial T2-weighted, three-dimensional, turbo spin-echo (3D TSE) images, targeted maximum-intensity projections (MIPs), and 3D volume reconstructions to depict anatomic details of the labyrinth. METHODS. In 24 volunteers, 3D TSE images were obtained. MIPs and 3D volume reconstructions were performed from the acquired data. All images were evaluated by three radiologists independently regarding the visualization of the different anatomic structures. RESULTS. In the axial slices, most anatomic details were visible in comparison with observations by the other modalities. The 2.5 windings of the cochlea were best depicted on the MIPs, Volume reconstructions rendered excellent spatial information regarding the vestibule and semicircular canals and were the only technique that demonstrated all three ampullae in all cases. CONCLUSIONS. Axial TSE images, MIPs, and 3D volume reconstructions are complementary modalities that provide different information. Our results suggest that improved diagnostic information can be obtained by applying these volume visualization reconstruction techniques.
引用
收藏
页码:337 / 342
页数:6
相关论文
共 50 条
  • [1] T2-weighted turbo spin-echo images, maximum-intensity projections, and three-dimensional volume-rendering for delineation of pathologies and anatomic details of the inner ear
    Krombach, GA
    Martiny, S
    Di Martino, E
    Westhofen, M
    Stanzel, S
    Haage, P
    Prescher, A
    Buecker, A
    Günther, RW
    INVESTIGATIVE RADIOLOGY, 2004, 39 (12) : 756 - 766
  • [2] Dehiscence of the superior and/or posterior semicircular canal: delineation on T2-weighted axial three-dimensional turbo spin-echo images, maximum intensity projections and volume-rendered images
    Gabriele A. Krombach
    Ercole Di Martino
    Sandra Martiny
    Andreas Prescher
    Patrick Haage
    Arno Buecker
    Rolf W. Günther
    European Archives of Oto-Rhino-Laryngology and Head & Neck, 2006, 263 : 111 - 117
  • [3] Dehiscence of the superior and/or posterior semicircular canal:: delineation on T2-weighted axial three-dimensional turbo spin-echo images, maximum intensity projections and volume-rendered images
    Krombach, GA
    Di Martino, E
    Martiny, S
    Prescher, A
    Haage, P
    Buecker, A
    Günther, RW
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2006, 263 (02) : 111 - 117
  • [4] T2-weighted three-dimensional turbo spin-echo MR of intracranial aneurysms
    Rubinstein, D
    Sandberg, EJ
    Breeze, RE
    Sheppard, SK
    Perkins, TG
    CajadeLaw, AG
    Simon, JH
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1997, 18 (10) : 1939 - 1943
  • [5] Semicircular canal dehiscence: comparison of T2-weighted turbo spin-echo MRI and CT
    G. A. Krombach
    T. Schmitz-Rode
    P. Haage
    E. DiMartino
    A. Prescher
    S. Kinzel
    R. W. Günther
    Neuroradiology, 2004, 46 : 326 - 331
  • [6] Semicircular canal dehiscence:: comparison of T2-weighted turbo spin-echo MRI and CT
    Krombach, GA
    Schmitz-Rode, T
    Haage, P
    DiMartino, E
    Prescher, A
    Kinzel, S
    Günther, RW
    NEURORADIOLOGY, 2004, 46 (04) : 326 - 331
  • [7] Inner ear volume measurements using high resolution three-dimensional heavily T2-weighted fast spin-echo MR imaging: Initial experience
    Melhem, ER
    Shakir, H
    Bakthavachalam, S
    Macdonald, BC
    Caruthers, S
    Jara, H
    RADIOLOGY, 1998, 209P : 423 - 423
  • [8] MR evaluation of rotator cuff tears: Comparison of turbo spin-echo STIR and fat-suppressed turbo spin-echo T2-weighted images
    Chun, KA
    Ahn, B
    Kim, YJ
    Kim, KT
    RADIOLOGY, 1999, 213P : 376 - 376
  • [9] Value of three-dimensional T2-weighted turbo spin-echo imaging with tissue-specific variable refocusing flip angle for 3-T magnetic resonance imaging of prostate cancer: comparison with conventional two- and three-dimensional T2-weighted turbo spin-echo imaging
    Utaru Tanaka
    Yoshiko Ueno
    Yukiko Morinaga
    Hideaki Miyake
    Katsusuke Kyotani
    Yu Ueda
    Kazuhiro Kitajima
    Keitaro Sofue
    Yuko Suenaga
    Kazuro Sugimura
    Satoru Takahashi
    Japanese Journal of Radiology, 2017, 35 : 707 - 717
  • [10] Value of three-dimensional T2-weighted turbo spin-echo imaging with tissue-specific variable refocusing flip angle for 3-T magnetic resonance imaging of prostate cancer: comparison with conventional two- and three-dimensional T2-weighted turbo spin-echo imaging
    Tanaka, Utaru
    Ueno, Yoshiko
    Morinaga, Yukiko
    Miyake, Hideaki
    Kyotani, Katsusuke
    Ueda, Yu
    Kitajima, Kazuhiro
    Sofue, Keitaro
    Suenaga, Yuko
    Sugimura, Kazuro
    Takahashi, Satoru
    JAPANESE JOURNAL OF RADIOLOGY, 2017, 35 (12) : 707 - 717