Development of an antibody-free ID-LC MS method for the quantification of procalcitonin in human serum at sub-microgram per liter level using a peptide-based calibration

被引:13
|
作者
Huynh, Huu-Hien [1 ,2 ]
Boeuf, Amandine [1 ]
Derbez-Morin, Maxence [1 ,3 ]
Dupuy, Anne-Marie [4 ]
Lalere, Beatrice [1 ]
Delatour, Vincent [1 ]
Vinh, Joelle [2 ]
机构
[1] Lab Natl Metrol & Essais LNE, Biomed & Organ Chem Dept, Paris, France
[2] Univ PSL, Biol Mass Spectrometry & Prote, SMBP, ESPCI Paris,CNRS,FRE2032, Paris, France
[3] Univ Paris Saclay, Dept Medicaments & Technol Sante DMTS, CEA, INRAE,SPI, Gif Sur Yvette, France
[4] Univ Montpellier I, Lab Biochim & Hormonol, CHU Montpellier, Montpellier, France
关键词
Procalcitonin; Sepsis; Isotope dilution mass spectrometry; Peptide-based calibration; ORTHOGONAL ARRAY OPTIMIZATION; THERAPEUTIC MONOCLONAL-ANTIBODIES; CHROMATOGRAPHY-MASS SPECTROMETRY; END-PRODUCTS SRAGE; ABSOLUTE QUANTIFICATION; MS/MS ANALYSIS; ENDOTHELIAL DYSFUNCTION; PROTEIN QUANTIFICATION; SOLUBLE RECEPTOR; HIGH-THROUGHPUT;
D O I
10.1007/s00216-021-03361-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The quantification of low abundant proteins in complex matrices by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) remains challenging. A measurement procedure based on optimized antibody-free sample preparation and isotope dilution coupled to LC-MS/MS was developed to quantify procalcitonin (PCT) in human serum at sub-microgram per liter level. A combination of sodium deoxycholate-assisted protein precipitation with acetonitrile, solid-phase extraction, and trypsin digestion assisted with Tween-20 enhanced the method sensitivity. Linearity was established through peptide-based calibration curves in the serum matrix (0.092-5.222 mu g/L of PCT) with a good linear fit (R2 >= 0.999). Quality control materials spiked with known amounts of protein-based standards were used to evaluate the method's accuracy. The bias ranged from -2.6 to +4.3%, and the intra-day and inter-day coefficients of variations (CVs) were below 2.2% for peptide-based quality controls. A well-characterized correction factor was determined and applied to compensate for digestion incompleteness and material loss before the internal standards spike. Results with metrological traceability to the SI units were established using standard peptide of well-characterized purity determined by peptide impurity corrected amino acid analysis. The validated method enables accurate quantification of PCT in human serum at a limit of quantification down to 0.245 mu g/L (bias -1.9%, precision 9.1%). The method was successfully applied to serum samples obtained from patients with sepsis. Interestingly, the PCT concentration reported implementing the isotope dilution LC-MS/MS method was twofold lower than the concentration provided by an immunoassay.
引用
收藏
页码:4707 / 4725
页数:19
相关论文
共 9 条
  • [1] Development of an antibody-free ID-LC MS method for the quantification of procalcitonin in human serum at sub-microgram per liter level using a peptide-based calibration
    Huu-Hien Huynh
    Amandine Bœuf
    Maxence Derbez-Morin
    Anne-Marie Dupuy
    Béatrice Lalere
    Vincent Delatour
    Joëlle Vinh
    Analytical and Bioanalytical Chemistry, 2021, 413 : 4707 - 4725
  • [2] Letter to the Editor regarding "Development of an antibody-free ID-LC MS method for the quantification of procalcitonin in human serum at sub-microgram per liter level using a peptide-based calibration"
    Toelke, Sebastian-Alexander
    Masetto, Thomas
    Grimmler, Matthias
    Bindila, Laura
    Schneider, Klaus
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (19) : 4917 - 4919
  • [3] Letter to the Editor regarding “Development of an antibody-free ID-LC MS method for the quantification of procalcitonin in human serum at sub-microgram per liter level using a peptide-based calibration”
    Sebastian-Alexander Tölke
    Thomas Masetto
    Matthias Grimmler
    Laura Bindila
    Klaus Schneider
    Analytical and Bioanalytical Chemistry, 2021, 413 : 4917 - 4919
  • [4] Response to Letter to the Editor regarding “Development of an antibody-free ID-LC MS method for the quantification of procalcitonin in human serum at sub-microgram per liter level using a peptide-based calibration”
    Huu-Hien Huynh
    Amandine Bœuf
    Maxence Derbez-Morin
    Anne-Marie Dupuy
    Béatrice Lalere
    Joëlle Vinh
    Vincent Delatour
    Analytical and Bioanalytical Chemistry, 2021, 413 : 4921 - 4922
  • [5] Development of an ID-LC–MS/MS method using targeted proteomics for quantifying cardiac troponin I in human serum
    Meltem Asicioglu
    Merve Oztug
    Nevin Gul Karaguler
    Clinical Proteomics, 2023, 20
  • [6] An antibody-free LC-MS/MS method for the quantification of sex hormone binding globulin in human serum and plasma
    Sleumer, Bas
    Zwerwer, Jordan
    van Faassen, Martijn
    Vos, Michel J.
    Bischoff, Rainer
    Kema, Ido P.
    van de Merbel, Nico C.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (07) : 1266 - 1274
  • [7] A selective and sensitive UPLC-ESI-MS/MS method for quantification of Pegylated Interferon Alfa-2b in human serum using signature peptide-based quantitation
    Kusuma, Manoj Bob
    Kashibhatta, Ravisekhar
    Jagtap, Sandeep S.
    Nadawade, Vijay
    Adsul, Suresh
    Moorkoth, Sudheer
    Bhat, Krishnamurthy
    Mody, Rustom
    Vithala, Praveen
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1180
  • [8] High-Throughput, Sensitive LC-MS Quantification of Biotherapeutics and Biomarkers Using Antibody-Free, Peptide-Level, Multiple-Mechanism Enrichment via Strategic Regulation of pH and Ionic and Solvent Strengths
    An, Bo
    Zhang, Ming
    Pu, Jie
    Shen, Shichen
    Qu, Yang
    Chen, Yuan-Ju
    Huo, Shihan
    Wang, Xue
    Polli, Joseph Ryan
    Balthasar, Joseph P.
    Herzog, Denis
    Ferrari, Luca
    Staack, Roland F.
    Richter, Wolfgang F.
    Otteneder, Michael B.
    Benincosa, Lisa J.
    Zhou, Shaolian
    Vazvaei, Faye
    Qu, Jun
    ANALYTICAL CHEMISTRY, 2019, 91 (05) : 3475 - 3483
  • [9] A selective and sensitive UPLC-ESI-MS/MS method for quantification of Pegylated Interferon Alfa-2b in human serum using signature peptide-based quantitation (vol 1180 , 122883]
    Kusuma, Manoj Bob
    Kashibhatta, Ravisekhar
    Jagtap, Sandeep S.
    Nadawade, Vijay
    Adsul, Suresh
    Moorkoth, Sudheer
    Bhat, Krishnamurthy
    Mody, Rustom
    Vithala, Praveen
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1192