Resistance of coated polyetheretherketone lumbar interbody fusion cages against abrasion under simulated impaction into the disc space

被引:8
|
作者
Kienle, Annette [1 ]
Krieger, Alexander [1 ]
Willems, Karel [2 ]
Wilke, Hans-Joachim [3 ]
机构
[1] SpineServ GmbH & Co KG, Soeflinger Str 100, D-89077 Ulm, Germany
[2] AZ Delta Hosp, Roeselare, Belgium
[3] Univ Ulm, Inst Orthoped Res & Biomech, Ulm, Germany
关键词
Nanocoating; calcium phosphate; titanium; vacuum plasma spray coating; fusion cage; abrasion; wear; bonding strength; spine; BOND STRENGTH; TITANIUM; COATINGS; DEBRIS; PEEK; ADHESION;
D O I
10.1177/2280800018782854
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In order to improve osseointegration, polyetheretherketone (PEEK) interbody fusion cages are frequently surface coated. The bonding strength of the coatings is mostly investigated under unrealistic loading conditions. To close this gap, in this study, uncoated and coated cages were loaded in a clinical setup in order to investigate their real resistance against abrasion. Six uncoated, six calcium phosphate (CaP) nanocoated, and six titanium (Ti) nanocoated PEEK cages were tested in this study. The experimental setup was designed to mimic cage impaction into the intervertebral disc space using polyurethane (PU) foam blocks as vertebral body substitutes. The cage surface was inspected before and after impaction, and their weight was measured. Impaction resulted in abrasion at the tip of the ridges on the implant surface. The mean weight loss was 0.39 mg for the uncoated cages, 0.57 mg for the CaP nanocoated cages, and 0.75 mg for the Ti nanocoated cages. These differences were statistically significant. In conclusion, differences between the three cage types were found concerning the amount of abrasion. However, all three cages lost less weight than a comparative Ti plasma spray coated cage, which showed a mean weight loss of 2.02 mg. This may be because the plasma spray coating is significantly thicker than the two nanocoatings. If compared with the permitted amount of weight loss derived from an FDA guidance document, which is approximately 1.7 mg, the wear of the Ti plasma spray coated cage is above this limit, whereas the wear for all other cage types is below.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Does impaction of titanium-coated interbody fusion cages into the disc space cause wear debris or delamination?
    Kienle, Annette
    Graf, Nicolas
    Wilke, Hans-Joachim
    SPINE JOURNAL, 2016, 16 (02): : 235 - 242
  • [2] Titanium-coated polyetheretherketone cages vs. polyetheretherketone cages in lumbar interbody fusion: A systematic review and meta-analysis
    Li, Songfeng
    Li, Xiyong
    Bai, Xiaohui
    Wang, Yunlu
    Han, Pengfei
    Li, Hongzhuo
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2023, 25 (06)
  • [3] Endplate Changes with Polyetheretherketone Cages in Posterior Lumbar Interbody Fusion
    Elfiky, Tarek Anwar
    Patil, Nirmal Dhananjay
    Allam, Yasser
    Ragab, Raafat
    ASIAN SPINE JOURNAL, 2020, 14 (02) : 229 - 237
  • [4] Early Fusion Status after Posterior Lumbar Interbody Fusion with Cortical Bone Trajectory Screw Fixation: A Comparison of Titanium-Coated Polyetheretherketone Cages and Carbon Polyetheretherketone Cages
    Sakaura, Hironobu
    Ohnishi, Atsunori
    Yamagishi, Akira
    Ohwada, Tetsuo
    ASIAN SPINE JOURNAL, 2019, 13 (02) : 248 - 253
  • [5] Comparison of fusion rates following transforaminal lumbar interbody fusion using polyetheretherketone cages or titanium cages with transpedicular instrumentation
    Nemoto, Osamu
    Asazuma, Takashi
    Yato, Yoshiyuki
    Imabayashi, Hideaki
    Yasuoka, Hiroki
    Fujikawa, Akira
    EUROPEAN SPINE JOURNAL, 2014, 23 (10) : 2150 - 2155
  • [6] Comparison of fusion rates following transforaminal lumbar interbody fusion using polyetheretherketone cages or titanium cages with transpedicular instrumentation
    Osamu Nemoto
    Takashi Asazuma
    Yoshiyuki Yato
    Hideaki Imabayashi
    Hiroki Yasuoka
    Akira Fujikawa
    European Spine Journal, 2014, 23 : 2150 - 2155
  • [7] Transforaminal lumbar interbody fusion using polyetheretherketone oblique cages with and without a titanium coating
    Rickert, M.
    Fleege, C.
    Tarhan, T.
    Schreiner, S.
    Makowski, M. R.
    Rauschmann, M.
    Arabmotlagh, M.
    BONE & JOINT JOURNAL, 2017, 99B (10): : 1366 - 1372
  • [8] Efficacy of Minimally Invasive Oblique Lumbar Interbody Fusion Using Polyetheretherketone Cages for Lumbar Pyogenic Spondylodiscitis Treatment
    Bae, Jong-Woo
    Lee, Sang-Soo
    Yang, Jae-Shin
    Seo, Eun-Min
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (09):
  • [9] Subsidence of Polyetheretherketone Intervertebral Cages in Minimally Invasive Lateral Retroperitoneal Transpsoas Lumbar Interbody Fusion
    Le, Tien V.
    Baaj, Ali A.
    Dakwar, Elias
    Burkett, Clinton J.
    Murray, Gisela
    Smith, Donald A.
    Uribe, Juan S.
    SPINE, 2012, 37 (14) : 1268 - 1273
  • [10] Posterior lumbar interbody fusion with various cages (TFC, BAK, Carbon, and CH cages) for degenerative lumbar disc disease
    Kim, YS