A comparison of algorithms for estimation of a respiratory signal from the surface electrocardiogram

被引:80
|
作者
O'Brien, Ciara [1 ]
Heneghan, Conor [1 ]
机构
[1] Univ Coll Dublin, Dept Elect & Elect Engn, Dublin 4, Ireland
关键词
ECG; respiration; sleep disordered breathing; AMEA; linear discriminant classification;
D O I
10.1016/j.compbiomed.2006.02.002
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
We provide a quantitative comparison between two new methods for deriving a respiratory signal from a single lead electrocardiogram, and the published technique of Behbehani et al. [An investigation of the mean electrical axis angle and respiration during sleep, in: Proceedings of the Second Joint EMBS/BMES Conference Houston, TX, USA, October 2002]. We conclude that (a) single ECG lead methods for estimating the respiratory signal are well correlated with inductance plethysmographs (correlation coefficients of approximately 0.75), (b) single lead estimates are more robust than methods based on the mean electrical axis, (c) body position has little impact on measurement accuracy and (d) single lead respiratory estimates can classify epochs of sleep disordered respiration with approximately 82% accuracy. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:305 / 314
页数:10
相关论文
共 50 条
  • [1] Performance evaluation of three methods for respiratory signal estimation from the electrocardiogram
    Correa, Lorena S.
    Laciar, Eric
    Torres, Abel
    Jane, Raimon
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 4760 - +
  • [2] Adaptive filtering in phase space for foetal electrocardiogram estimation from an abdominal electrocardiogram signal and a thoracic electrocardiogram signal
    Wei, Z.
    Hongxing, L.
    Jianchun, C.
    IET SIGNAL PROCESSING, 2012, 6 (03) : 171 - 177
  • [3] An assessment of algorithms to estimate respiratory rate from the electrocardiogram and photoplethysmogram
    Charlton, Peter H.
    Bonnici, Timothy
    Tarassenko, Lionel
    Clifton, David A.
    Beale, Richard
    Watkinson, Peter J.
    PHYSIOLOGICAL MEASUREMENT, 2016, 37 (04) : 610 - 626
  • [4] A comparison of ICA algorithms in surface EMG signal processing
    Naik, Ganesh R.
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2011, 6 (04) : 363 - 374
  • [5] Finger and forehead PPG signal comparison for respiratory rate estimation
    Hernando, A.
    Pelaez-Coca, M. D.
    Lozano, M. T.
    Lazaro, J.
    Gil, E.
    PHYSIOLOGICAL MEASUREMENT, 2019, 40 (09)
  • [6] Two Algorithms for Detecting Respiratory Rate from ECG Signal
    Kim, J. M.
    Hong, J. H.
    Kim, N. J.
    Cha, E. J.
    Lee, T. S.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 4069 - +
  • [7] An Integrated Approach for Fetal Heart Rate Estimation from Abdominal Electrocardiogram Signal
    WEI Xueyun
    ZHENG Wei
    Chinese Journal of Electronics, 2019, 28 (06) : 1198 - 1203
  • [8] Cuff-less blood pressure estimation from photoplethysmography signal and electrocardiogram
    Yao, Li-Ping
    Pan, Zhong-liang
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (02) : 397 - 408
  • [9] Cuff-less blood pressure estimation from photoplethysmography signal and electrocardiogram
    Li-Ping Yao
    Zhong-liang Pan
    Physical and Engineering Sciences in Medicine, 2021, 44 : 397 - 408
  • [10] A Comparison Study of Signal Processing Tools for Denoising of Electrocardiogram Signal
    Rout, Nikhilesh Chandra
    Garnaik, Sarmila
    Sethi, Kabiraj
    2017 INTERNATIONAL CONFERENCE ON INNOVATIONS IN CONTROL, COMMUNICATION AND INFORMATION SYSTEMS (ICICCI-2017), 2017, : 379 - 383