Hydraulic analysis of EU-DEMO divertor plasma facing components cooling circuit under nominal operating scenarios

被引:9
|
作者
Di Maio, P. A. [1 ]
Garitta, S. [1 ]
You, J. H. [2 ]
Mazzone, G. [3 ]
Vallone, E. [1 ]
机构
[1] Univ Palermo, Viale Sci,Edificio 6, I-90128 Palermo, Italy
[2] Max Planck Inst Plasma Phys E2M, Boltzmann Str 2, D-85748 Garching, Germany
[3] ENEA CR Frascati, Dept Fus & Technol Nucl Safety & Secur, Via E Fermi 45, I-00044 Rome, Italy
关键词
DEMO; Divertor; Plasma facing components; CFD analysis; Thermofluid-dynamics; BEHAVIOR; DESIGN;
D O I
10.1016/j.fusengdes.2019.03.030
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Within the framework of the Work Package DIV 1 - "Divertor Cassette Design and Integration" of the EUROfusion action, a research campaign has been jointly carried out by University of Palermo and ENEA to investigate the steady state thermal-hydraulic behaviour of the DEMO divertor cassette cooling circuit, focussing the attention on its Plasma Facing Components (PFCs). The research campaign has been carried out following a theoretical-computational approach based on the Finite Volume Method and adopting the commercial Computational Fluid-Dynamic code ANSYS-CFX. A realistic model of the PFCs cooling circuit has been analysed, specifically embedding each Plasma Facing Unit (PFU) cooling channel with the foreseen swirl tape turbulence promoter, hence resulting in a finite volume model much more detailed than those assessed in previous analyses. Its thermal-hydraulic performances have been numerically evaluated under nominal steady state conditions, also comparing the obtained results with the corresponding outcomes of analogous analyses carried out for a simplified PFCs configuration, without swirl tapes. Moreover, the main thermal-hydraulic parameters have been evaluated in order to check whether the considered PFCs cooling circuit might fulfil the total pressure drop requirement (Delta p < 1.4 MPa), providing a uniform cooling of the Vertical Target PFU channels with a viable CHF margin ( > 1.4). The PFCs cooling circuit thermal-hydraulic behaviour has been additionally assessed at alternative operative conditions, issued to check the viability of a coolant velocity reduction, in order to minimize corrosion and vibrations inside the PFU channels. Models, loads and boundary conditions assumed for the analyses are herewith reported and critically discussed, together with the main results obtained.
引用
收藏
页码:1764 / 1768
页数:5
相关论文
共 14 条
  • [1] On the numerical assessment of the thermal-hydraulic operating map of the DEMO Divertor Plasma Facing Components cooling circuit
    Di Maio, P. A.
    Burlon, R.
    Giardina, M.
    You, J. H.
    Mazzone, G.
    Vallone, E.
    [J]. FUSION ENGINEERING AND DESIGN, 2020, 161
  • [2] Thermal-hydraulic behaviour of the DEMO divertor plasma facing components cooling circuit
    Di Maio, P. A.
    Garitta, S.
    You, J. H.
    Mazzone, G.
    Vallone, E.
    [J]. FUSION ENGINEERING AND DESIGN, 2017, 124 : 415 - 419
  • [3] On the thermal-hydraulic optimization of DEMO divertor plasma facing components cooling circuit
    Di Maio, P. A.
    Garitta, S.
    You, J. H.
    Mazzone, G.
    Marino, M.
    Vallone, E.
    [J]. FUSION ENGINEERING AND DESIGN, 2018, 136 : 1438 - 1443
  • [4] Hydraulic assessment of an upgraded pipework arrangement for the DEMO divertor plasma facing components cooling circuit
    Di Maio, P. A.
    Burlon, R.
    Mazzone, G.
    Quartararo, A.
    Vallone, E.
    You, J. H.
    [J]. FUSION ENGINEERING AND DESIGN, 2021, 168
  • [5] Thermal-hydraulic study of the Primary Heat Transport System of the EU-DEMO Divertor Plasma Facing Components
    Vacca, S.
    Agnello, G.
    Bongiovi, G.
    Castrovinci, F. M.
    Chiovaro, P.
    Di Maio, P. A.
    Maviglia, F.
    Moscato, I.
    Quartararo, A.
    Siccinio, M.
    Vallone, E.
    [J]. FUSION ENGINEERING AND DESIGN, 2024, 201
  • [6] Analysis of highly radiative scenarios for the EU-DEMO divertor target protection
    Subba, F.
    Coster, D. P.
    Juanes, A. N. Escat
    Fable, E.
    Wenninger, R.
    Zanino, R.
    [J]. CONTRIBUTIONS TO PLASMA PHYSICS, 2018, 58 (6-8) : 758 - 764
  • [7] Selection of EU-DEMO divertor operating conditions: water cooling thermal-hydraulic parameters and power exhaust capabilities
    Marzullo, D.
    Spagnuolo, G. A.
    Aiello, G.
    Boscary, J.
    Graziosi, G.
    Moscato, I.
    Quartararo, A.
    You, J. H.
    [J]. FUSION ENGINEERING AND DESIGN, 2024, 203
  • [8] Thermofluid-dynamic assessment of the EU-DEMO divertor single-circuit cooling option
    Quartararo, A.
    Basile, S.
    Castrovinci, F. M.
    Di Maio, P. A.
    Giardina, M.
    Mazzone, G.
    Vallone, E.
    You, J. H.
    [J]. FUSION ENGINEERING AND DESIGN, 2023, 188
  • [9] Advances in material phase change modelling approach for EU-DEMO limiter?s plasma-facing components
    Richiusa, M. L.
    Ireland, P.
    Maviglia, F.
    Nicholas, J.
    Vizvary, Z.
    [J]. FUSION ENGINEERING AND DESIGN, 2023, 189
  • [10] Analysis of steady state thermal-hydraulic behaviour of the DEMO divertor cassette body cooling circuit
    Di Maio, P. A.
    Garitta, S.
    You, J. H.
    Mazzone, G.
    Vallone, E.
    [J]. FUSION ENGINEERING AND DESIGN, 2017, 124 : 437 - 441