Innovative monochromatic x-ray source for high-quality and low-dose medical imaging

被引:12
|
作者
Silver, Eric H. [1 ]
Shulman, Seth D. [1 ]
Rehani, Madan M. [2 ]
机构
[1] Imagine Sci Inc, 90 Kerry Pl, Norwood, MA 02062 USA
[2] Massachusetts Gen Hosp, Boston, MA 02114 USA
关键词
monochromatic x‐ rays; image quality; mammography; phantoms; radiation dose; MAMMOGRAPHY; RADIATION; DETECTORS;
D O I
10.1002/mp.14677
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose An estimated 377 million diagnostic and interventional radiological exams are performed annually in the United States and approximately 4 to 5 billion globally. All use x-ray tubes that emit x-rays over a broad energy band, a technology that is more than a century old. Only a small fraction of the radiation is useful for imaging while the remaining fraction either increases the radiation dose received by the patient or degrades the image. Monochromatic x-rays can provide lower dose images in many of these radiological applications while maintaining or improving image quality. We report the development of the first monochromatic x-ray source suitable for low-dose, high-quality imaging in the clinic and demonstrate its first application and performance with mammography phantoms. Methods X-ray fluorescence was used to generate monochromatic x-rays with selectable energies from 18 to 60 keV. This patented technology was incorporated into a laboratory prototype of a monochromatic x-ray mammography system. Image quality was evaluated as a function of radiation dose in standard breast phantoms using the signal-to-noise ratio (SNR) measured for high and low contrast masses and microcalcifications. Spatial imaging properties were assessed from these images as well as from modulation transfer function (MTF) analysis. Measurements using an iodine contrast agent were also performed. The results were compared to those obtained using a commercially available, conventional x-ray mammography system. Results Our prototype system reduced radiation dose by factors of five to ten times for the same SNRs as obtained from the conventional system. This performance was demonstrated in phantoms simulating a wide range of lesion sizes and microcalcifications in a variety of breast thicknesses. The high SNRs for very thick breast phantoms provide evidence that screening with less breast compression is possible while maintaining image quality. Contrast-enhanced digital mammography (CEDM) with monochromatic x-rays was shown to provide a simpler and more effective technique at substantially lower radiation dose. The MTF value at 20% was 9 lp/mm. Conclusions The monochromatic x-ray system is more sensitive for imaging a wide range of breast sizes and compositions than conventional broadband mammography. High image quality and lower dose are its hallmarks. It also makes CEDM much more effective than current methods developed for use with conventional broadband mammography systems.
引用
收藏
页码:1064 / 1078
页数:15
相关论文
共 50 条
  • [1] Low-dose phase contrast x-ray medical imaging
    Arfelli, F
    Assante, M
    Bonvicini, V
    Bravin, A
    Cantatore, G
    Castelli, E
    Dalla Palma, L
    Di Michiel, M
    Longo, R
    Olivo, A
    Pani, S
    Pontoni, D
    Poropat, P
    Prest, M
    Rashevsky, A
    Tromba, G
    Vacchi, A
    Vallazza, E
    Zanconati, F
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10): : 2845 - 2852
  • [2] MONOCHROMATIC IMAGING OF AN X-RAY SYNCHROTRON SOURCE
    FRAENKEL, BS
    KALMAN, ZH
    PHYSICA SCRIPTA, 1990, 41 (04): : 400 - 403
  • [3] A Preliminary Study on Low-dose X-ray Imaging Using Parametric X-ray
    Sakae, Toshiro
    Hayakawa, Yasushi
    Takahashi, Yumiko
    Kuwada, Takao
    Nakao, Keisuke
    Nogami, Kyoko
    Inagaki, Manabu
    Tanaka, Toshinari
    Sato, Isamu
    Hirayama, Katsunori
    Sekiya, Kotarou
    Kaneda, Takashi
    Suemitsu, Masaaki
    Okada, Hiroyuki
    Yamamoto, Hirotsugu
    Hata, Saya
    Akimoto, Yoshiaki
    Fukumoto, Masahiko
    Makimura, Masaharu
    JOURNAL OF HARD TISSUE BIOLOGY, 2011, 20 (01) : 31 - 35
  • [4] PORTABLE LOW-DOSE X-RAY IMAGING-SYSTEM
    YIN, LI
    SELTZER, SM
    TROMBKA, JI
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1977, 27 (NOV): : 167 - 168
  • [5] Characterization of an avalanche detector for low-dose X-ray imaging
    Wronski, M.
    Reznik, A.
    Rowlands, J.
    Zhao, W.
    MEDICAL PHYSICS, 2009, 36 (09) : 4321 - 4321
  • [6] Dose Correction in Medical X-ray Imaging in Low Dose Regime
    Zheng, Xiaoming
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2016, 6 (07) : 1818 - 1822
  • [7] Sparse2Noise: Low-dose synchrotron X-ray tomography without high-quality reference data
    Duan, Xiaoman
    Ding, Xiao Fan
    Li, Naitao
    Wu, Fang-Xiang
    Chen, Xiongbiao
    Zhu, Ning
    COMPUTERS IN BIOLOGY AND MEDICINE, 2023, 165
  • [8] High-quality low-dose SIMOX wafers
    NTT System Electronics Lab, Atsugi-shi, Japan
    IEICE Trans Electron, 3 (364-369):
  • [9] High-quality low-dose SIMOX wafers
    Nakashima, S
    IEICE TRANSACTIONS ON ELECTRONICS, 1997, E80C (03) : 364 - 369
  • [10] Edge enhancement algorithm for low-dose X-ray fluoroscopic imaging
    Lee, Min Seok
    Park, Chul Hee
    Kang, Moon Gi
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2017, 152 : 45 - 52