Hierarchical Bayesian Calibration and On-line Updating Method for Influence Coefficient of Automatic Dynamic Balancing Machine

被引:4
|
作者
Zhang Jian [1 ]
Wu Jianwei [1 ]
Ma Zhiyong [1 ]
机构
[1] Zhejiang Univ, Mech Design Inst, Hangzhou 310027, Peoples R China
关键词
influence coefficient; hierarchical Bayesian calibration; online updating; dynamic balancing; Markov Chain Monte Carlo(MCMC);
D O I
10.3901/CJME.2009.06.876
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Measurement error of unbalance's vibration response plays a crucial role in calibration and on-line updating of influence coefficient(IC). Focusing on the two problems that the moment estimator of data used in calibration process cannot fulfill the accuracy requirement under small sample and the disturbance of measurement error cannot be effectively suppressed in updating process, an IC calibration and on-line updating method based on hierarchical Bayesian method for automatic dynamic balancing machine was proposed. During calibration process, for the repeatedly-measured data obtained from experiments with different trial weights, according to the fact that measurement error of each sensor had the same statistical characteristics, the joint posterior distribution model for the true values of the vibration response under all trial weights and measurement error was established. During the updating process, information obtained from calibration was regarded as prior information, which was utilized to update the posterior distribution of IC combined with the real-time reference information to implement online updating. Moreover, Gibbs sampling method of Markov Chain Monte Carlo(MCMC) was adopted to obtain the maximum posterior estimation of parameters to be estimated. On the independent developed dynamic balancing testbed, prediction was carried out for multiple groups of data through the proposed method and the traditional method respectively, the result indicated that estimator of influence coefficient obtained through the proposed method had higher accuracy; the proposed updating method more effectively guaranteed the measurement accuracy during the whole producing process, and meantime more reasonably compromised between the sensitivity of IC change and suppression of randomness of vibration response.
引用
收藏
页码:876 / 882
页数:7
相关论文
共 13 条
  • [2] Rigid rotor dynamic balancing with the influence coefficient method
    Xu, Xiang
    Fan, Ping Ping
    [J]. Sensors and Transducers, 2013, 157 (10): : 317 - 324
  • [3] Balancing plasticity and stability of on-line learning based on hierarchical Bayesian adaptation of forgetting factors
    Hirayama, Junichiro
    Yoshimoto, Junichiro
    Ishii, Shin
    [J]. NEUROCOMPUTING, 2006, 69 (16-18) : 1954 - 1961
  • [4] A Dynamic Calibration Method of Broad Band Infrared On-line Measurement System
    Sun, Xiao-Gang
    Qiu, Chao
    [J]. PROCEEDINGS OF THE 2012 SECOND INTERNATIONAL CONFERENCE ON INSTRUMENTATION & MEASUREMENT, COMPUTER, COMMUNICATION AND CONTROL (IMCCC 2012), 2012, : 414 - 417
  • [5] An on-line anomaly identifying method for calibration devices in an automatic verification system for electricity smart meters
    Jiao, Yang
    Chen, Qing
    Bao, Zhiwei
    Pan, Linqiang
    Li, Hongbin
    [J]. MEASUREMENT, 2021, 180
  • [6] Rigid Rotor Dynamic Balancing by Two-plane Correction with the Influence Coefficient Method
    Xu, Xiang
    Fan, PingPing
    [J]. MACHINE DESIGN AND MANUFACTURING ENGINEERING II, PTS 1 AND 2, 2013, 365-366 : 211 - +
  • [7] Solving method of influence coefficient for rotor dynamic balancing based on finite element model
    [J]. Bin, G. (abin811025@163.com), 1600, Nanjing University of Aeronautics an Astronautics (33):
  • [8] The Application of Ridge Regression in Dynamic Balancing of Flexible Rotors Based on Influence Coefficient Method
    秦鹏
    蔡萍
    胡庆翰
    李英霞
    [J]. Journal of Shanghai Jiaotong University(Science), 2006, (01) : 93 - 98
  • [9] On-line measurement technologies and identification method of dynamic response of machine tool structures
    Weng, ZY
    Xie, WD
    Huang, YS
    Yuan, JL
    [J]. PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 3, 2002, : 181 - 184
  • [10] Calibration of a Hub Dynamic Balancing Machine Based on the Least Squares Method and Systematic Error Analysis
    Cao, Yuan
    Li, Fang
    Cao, Jianguo
    Wang, Tao
    [J]. IEEE ACCESS, 2020, 8 : 178746 - 178754