Evaluation of bond strength of dual resin cements to CAD/CAM-created lithium disilicate ceramic

被引:2
|
作者
Sczepanski, Felipe [1 ]
Brunnquell, Claudia R. [2 ]
Berger, Sandrine B. [3 ]
Paloco, Eloisa A. [3 ]
Lopes, Murilo B. [3 ]
Drumond, Amauri C. [3 ]
Gonzalez, Alejandra H. [3 ]
Guiraldo, Ricardo D. [3 ]
机构
[1] State Univ North Parana UENP, Dept Dent, Jacarezinho, Brazil
[2] State Univ North Parana UENP, Dept Physiotherapy, Jacarezinho, Brazil
[3] Univ North Parana UNOPAR, Dept Restorat Dent, Rua Marselha 183, BR-86041140 Londrina, Parana, Brazil
来源
MINERVA STOMATOLOGICA | 2020年 / 69卷 / 03期
关键词
Ceramics; Shear strength; Cementation; SILANE COUPLING AGENTS; UNIVERSAL ADHESIVE; SURFACE TREATMENTS; ZIRCONIA; RESTORATIONS; PORCELAIN; SYSTEMS;
D O I
10.23736/S0026-4970.19.04291-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BACKGROUND: The objective was to examine the microshear bond strength values of different dual resin cements to computer-aided design (CAD)/computer-aided manufacturing (CAM)-created ceramics containing lithium disilicate, which underwent different surface treatments. METHODS: Two dual resin cements (RelyX ARC and RelyX Ultimate) and three surface treatments of lithium disilicate ceramic blocks (Ceramic Primer (CP; containing silane) plus Adper Scotchbond Multipurpose (ASM) adhesive; CP plus Single Bond Universal (SBU) adhesive; and SBU adhesive alone) were tested. The SBU adhesive includes silane in its formulation. Each sample underwent a microshear test and bond strength values were subjected to analysis of variance (ANOVA) followed by Tukey's test (a=0.05). Fracture patterns were also observed with light microscopy. RESULTS: RelyX ARC treated with CP+ASM or CP+SBU presented resistance values that were significantly higher than the same treatments for RelyX Ultimate. Conversely, for the blocks treated with SBU alone, the mean resistance value for RelyX Ultimate was higher than that of RelyX ARC. Regarding the different types of treatment for each resin, the mean resistance value of RelyX ARC treated with CP+ASM was significantly highest, followed by treatment with CP+SBU and SBU treatment alone. Meanwhile, RelyX Ultimate treated with CP+ASM or CP+SBU presented resistance values that were significantly higher than SBU treatment alone. In all of the groups, an adhesive fracture pattern was predominantly observed. CONCLUSIONS: The present results indicate thatsilanization is important for ASM and SBU adhesives to be effective.
引用
收藏
页码:153 / 158
页数:6
相关论文
共 50 条
  • [1] Recycling CAD/CAM Lithium Disilicate Ceramic: Effect of Surface Treatment and Aging on the Bond Strength to Resin Cement
    de Miranda, Larissa Mendonca
    Caldas, Aparecida TharIla Leite
    Moura, Dayanne Monielle Duarte
    Souza, Karina Barbosa
    de Assuncao, Isauremi Vieira
    Ozcan, Mutlu
    de Assuncao e Souza, Rodrigo Othavio
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2024, 37 (06) : 675 - 685
  • [2] Evaluation of the Bond Strength of Resin Cements to New Lithium Disilicate-Reinforced Glass Ceramic Materials
    Zhu, Lin-Lin
    Ji, Yang
    Wang, Qiang
    Qiu, Li-Hong
    SCIENCE OF ADVANCED MATERIALS, 2019, 11 (11) : 1501 - 1509
  • [3] Adhesive Bond Strength of Resin Cements to CAD-CAM Hybrid Ceramic Materials
    Maawadh, Ahmed Mohammed
    BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS, 2020, 13 (02): : 438 - 444
  • [4] Shear bond strength of CAD/CAM resin-based composite specimens to human dentin in comparison to CAD/CAM lithium disilicate ceramic specimens in vitro
    Droese, Laura Karina
    Donnermeyer, David
    Dammaschke, Till
    QUINTESSENCE INTERNATIONAL, 2022, 53 (05): : 384 - 392
  • [5] Shear bond strength of composite resin cements to lithium disilicate ceramics
    Kumbuloglu, O
    Lassila, LVJ
    User, A
    Toksavul, S
    Vallittu, PK
    JOURNAL OF ORAL REHABILITATION, 2005, 32 (02) : 128 - 133
  • [6] Evaluation of the shear bond strength of two resin cements on different CAD/CAM materials
    Secilmis, Asli
    Ustun, Ozlem
    Buyukhatipoglu, Isil Kecik
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2016, 30 (09) : 983 - 993
  • [7] Bond strength to different CAD/CAM lithium disilicate reinforced ceramics
    Alhomuod, Mona
    Phark, Jin-Ho
    Duarte Jr, Sillas
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2023, 35 (01) : 129 - 137
  • [8] "No-Primer" Resin Cementation of Lithium Disilicate Ceramic: A Microtensile Bond Strength Evaluation
    Awad, Mohamed M.
    Alhalabi, Feras
    Alanazi, Abdulaziz Abdullah
    Alanazi, Abdulaziz Ali
    Alshahrani, Ghanem Abdullah
    Fu, Cheryl
    Albaijan, Refal Saad
    Alkattan, Rana
    Fawzy, Amr S.
    MATERIALS, 2024, 17 (01)
  • [9] The Influence of Surface Standardization of Lithium Disilicate Glass Ceramic on Bond Strength to a Dual Resin Cement
    Brum, R.
    Mazur, R.
    Almeida, J.
    Borges, G.
    Caldas, D.
    OPERATIVE DENTISTRY, 2011, 36 (05) : 478 - 485
  • [10] Microtensile Bond Strength Between Self-Adhesive Resin Cements and Resin Based Ceramic CAD/CAM Block
    Berkman, Meric
    Tuncer, Safa
    Tekce, Neslihan
    Karabay, Ferda
    Demirci, Mustafa
    ODOVTOS INTERNATIONAL JOURNAL OF DENTAL SCIENCES, 2021, 23 (01) : 116 - 125