Spectral response of optical fiber probe with closely spaced fibers

被引:1
|
作者
Jacques, Steven L. [1 ]
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
关键词
Optical fiber; spectroscopy; Monte Carlo; REFLECTANCE SPECTROSCOPY; DIFFUSE-REFLECTANCE; DIAGNOSIS; CANCER;
D O I
10.21037/qims-20-816
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Optical fiber probe spectroscopy can characterize the blood content, hemoglobin oxygen saturation, water content, and scattering properties of a tissue. A narrow probe using closely spaced fibers can access and characterize a local tissue site, but analysis requires the proper light transport theory. Methods: Monte Carlo simulations of photon transport specified the response of a two-fiber probe as a function of optical properties in a homogeneous tissue. The simulations used the dimensions of a commercial fiber probe (400-micron-diameter fibers separated by 80-microns of cladding) to calculate the response to a range of 20 absorption and 20 reduced scattering values. The 400 simulations yielded an analysis grid (lookup table) to interpolate the probe response to any given pair of absorption and scattering properties. Results: The probe in contact with tissue is not sensitive to low absorption but sensitive to scattering, as occurs for red to near-infrared spectra. The probe is sensitive to both absorption and scattering for shorter visible spectra (purple-orange). The non-contact probe held above the tissue delivers light to/from a spot on the tissue and fails to collect light that spreads laterally to escape outside the collection spot. Such partial collection can distort the spectra. Conclusions: Optical fiber spectroscopy using closely spaced fibers requires proper calibration. An analysis subroutine is provided for analysis of a two-fiber probe with the dimensions of a commercial probe (Ocean Insight), but the method can be applied to any probe design. A closely spaced fiber probe can document blood in the shorter visible wavelengths, but has difficulty detecting red and near-infra-red absorption. Hence detection of hydration is difficult. The strength of the closely spaced fiber probe is detecting scattering that depends on tissue structure at the micron to sub-micron scale.
引用
收藏
页码:1023 / +
页数:14
相关论文
共 50 条
  • [1] Residual stresses in undirectional composites with closely spaced fibers
    Kouris, Demitris, 1600, American Ceramic Soc, Westerville, OH, United States (78):
  • [2] Residual stresses in unidirectional composites with closely spaced fibers
    Kouris, D
    Meisner, M
    JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1995, 78 (12) : 3316 - 3322
  • [3] NONSTATIONARY RESPONSE OF STRUCTURES WITH CLOSELY SPACED FREQUENCIES
    XU, KM
    IGUSA, TR
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 1992, 118 (07): : 1387 - 1405
  • [4] Hybrid response control of closely spaced buildings
    Lee, GC
    Tong, M
    Wu, YH
    ADVANCES IN BUILDING TECHNOLOGY, VOLS I AND II, PROCEEDINGS, 2002, : 505 - 512
  • [5] Electromagnetic response of closely spaced metal meshes
    Taylor, Melita C.
    Hibbins, Alastair P.
    Sambles, J. Roy
    PHYSICAL REVIEW B, 2012, 86 (03)
  • [6] High-power spectral beamsplitter for closely spaced frequencies
    Marciniak, Ch D.
    Rischka, A.
    Wolf, R. N.
    Biercuk, M. J.
    OPTICS EXPRESS, 2020, 28 (08) : 11372 - 11379
  • [7] Spectral estimation and resolution of closely spaced radar target scatterers
    Ismail, TH
    Mustafa, AM
    Mismar, MJ
    INTERNATIONAL JOURNAL OF ELECTRONICS, 1997, 83 (03) : 417 - 427
  • [8] SCATTERING OF OPTICAL RADIATION BY A SYSTEM OF CLOSELY SPACED SEATLERS
    VEDERNIKOVA, EA
    KABANOV, MV
    OPTIKA I SPEKTROSKOPIYA, 1974, 37 (01): : 130 - 135
  • [9] Polarized spectral combs probe optical fiber surface plasmons
    Caucheteur, Christophe
    Voisin, Valerie
    Albert, Jacques
    OPTICS EXPRESS, 2013, 21 (03): : 3055 - 3066
  • [10] CONSERVATISM IN SUMMATION RULES FOR CLOSELY SPACED MODES - RESPONSE
    KELLY, JM
    SACKMAN, JL
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1981, 9 (01): : 89 - 90