Residual life prediction of service exposed main steam pipe of boilers in a thermal power plant

被引:30
|
作者
Ray, AK [1 ]
Tiwari, YN [1 ]
Sinha, RK [1 ]
Chaudhuri, S [1 ]
Singh, R [1 ]
机构
[1] Natl Met Lab, Jamshedpur 831007, Bihar, India
关键词
service exposed; boiler failures; stress rupture test; tensile properties; remaining life;
D O I
10.1016/S1350-6307(99)00024-2
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper deals with residual life prediction methodology for more than 12.5 years service exposed main steam pipes of various boilers in a thermal power plant. Health assessment was made using destructive accelerated stress rupture and tensile tests at different temperatures, and some nondestructive tests. There was no evidence of localised damage in the form of surface cracks, cavitation or dents in the service exposed main steam pipes of all the boilers. So far as the remaining life at 550 degrees C is concerned, it is possible to obtain a life of greater than 100,000 h at the hoop stress level of the service exposed pipes, provided no localised damage in the form of cracks or dents have been developed. It is recommended that a health check may be carried out after 50,000 h of service exposure at 550 degrees C. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:359 / 376
页数:18
相关论文
共 50 条
  • [1] Mechanical property evaluation and remaining life assessment of service-exposed steam pipe of boilers in a thermal power plant
    Ray, AK
    Tiwari, YN
    Sinha, RK
    Sinha, SK
    Roy, PK
    Singh, R
    Chaudhuri, S
    [J]. HIGH TEMPERATURE MATERIALS AND PROCESSES, 2001, 20 (01) : 39 - 50
  • [2] Residual life assessment of F12 main steam pipe system in thermo-power plant
    School of Material Science and Engineering, Tongji University, Shanghai 200092, China
    不详
    [J]. Tongji Daxue Xuebao, 2008, 1 (86-91):
  • [3] Determining the residual service life of the steam lines at the Estonia thermal power station
    Klevtsov, I.A.
    Tallermo, H.I.
    [J]. Teploenergetika, 2002, (04): : 70 - 74
  • [4] Modeling of Main Steam Parameters in Large Thermal Power Plant
    Wen Xiaoqiang
    Jian Shuguang
    [J]. 2016 3RD INTERNATIONAL CONFERENCE ON MECHANICS AND MECHATRONICS RESEARCH (ICMMR 2016), 2016, 77
  • [5] Cause Analysis and Solution of Main Steam Pipe Vibration in a Nuclear Power Plant
    某核电厂主蒸汽管道振动原因分析及解决方案探讨
    [J]. Zhan, Minming (zhanminming@snerdi.com.cn), 1600, Atomic Energy Press (42): : 138 - 142
  • [6] Methods and Systems for High-temperature Strain Measurement of the Main Steam Pipe of a Boiler of a Power Plant While in Service
    Chen Guang
    Feng Qibo
    Ding Keqin
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF KOREA, 2016, 20 (06) : 770 - 777
  • [7] INCREASING SERVICE LIFE OF ELEMENTS OF STEAM BOILERS AND TURBINES
    UNKSOV, EP
    TRUSOV, LP
    KRYAKIN, IR
    [J]. THERMAL ENGINEERING, 1971, 18 (08) : 1 - &
  • [8] Remaining lifetime assessment of power plant steam boilers
    Liska, Vaclav
    Mentl, Vaclav
    [J]. BALTICA VIII: LIFE MANAGEMENT AND MAINTENANCE FOR POWER PLANTS, VOL 2, 2010, 265 : 167 - 175
  • [9] Remaining life assessment of service exposed reheater and superheater tubes in a boiler of a thermal power plant
    Ray, AK
    Tiwari, YN
    Chaudhuri, S
    Ranganath, VR
    Sivaprasad, S
    Roy, PK
    Das, G
    GhoshChowdhury, S
    Kumar, P
    Ghosh, RN
    [J]. HIGH TEMPERATURE MATERIALS AND PROCESSES, 2002, 21 (1-2) : 109 - 121
  • [10] STEAM TEMPERATURE PREDICTION CONTROL FOR THERMAL POWER-PLANT
    SATO, Y
    NOMURA, M
    MATSUMOTO, H
    IIOKA, M
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1984, 103 (09): : 2382 - 2387