A multicolor, no-lyse, no-wash assay for the absolute counting of CD34+ cells by flow cytometry

被引:20
|
作者
Alvarez-Larran, A [1 ]
Jover, L [1 ]
Marin, P [1 ]
Petriz, J [1 ]
机构
[1] Univ Barcelona, IDIBAPS, Hosp Clin, Serv Hemoterapia & Hemostasia, E-08036 Barcelona, Spain
来源
CYTOMETRY | 2002年 / 50卷 / 05期
关键词
flow cytometry; CD34; hematopoietic stem cells; whole blood; nucleic acid stain; LDS-751; SYTO-13;
D O I
10.1002/cyto.10129
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: We previously developed a method for counting CD34(+) cells in unlysed whole blood. This method was applied to normal human bone marrow, peripheral blood after mobilization of progenitor cells, leukapheresis products, and cord blood and was validated with two different lyse-no wash methods. However, the main advantage that we described, erythrocyte discrimination using nucleic acid staining, was also the main restriction because additional markers for the immunologic characterization of CD34(+) cells cannot be included. Methods: We used SYT0-13 and fluorescein isothiocyanate (FITC)-CD45 staining (FL1) instead of SYT0-13 and phycoerythrin (PE)Cy5-CD45 staining (FL3) to leave the third and fourth fluorescence parameters available for further characterization of CD34(+) cells. The new method was validated by applying it to cord blood samples (n=20). Results: FITC-CD45 antibody gave a 1.7-fold increase in mean fluorescence intensity over SYT0-13 alone. From absolute counts (CD34(+) cells per microliter), we plotted the differences between the methods against their mean, showing that differences fell into acceptable ranges. Conclusions: No-lyse procedures may represent an advance for cell immunophenotyping and it could be applied to the measurement of additional markers.
引用
收藏
页码:249 / 253
页数:5
相关论文
共 50 条
  • [1] NO-LYSE NO-WASH IMMUNOPHENOTYPING USING ACOUSTIC CYTOMETRY
    Kerndt, Rick
    Bradford, Jolene A.
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2011, 80B (06) : 383 - 383
  • [2] DRAQ-5 based no-lyse, no-wash bone marrow aspirate evaluation by flow cytometry
    Allan, R. W.
    Ansari-Lari, M. A.
    Jordan, S.
    MODERN PATHOLOGY, 2007, 20 : 232A - 232A
  • [3] DRAQ-5 based no-lyse, no-wash bone marrow aspirate evaluation by flow cytometry
    Allan, R. W.
    Ansari-Lari, M. A.
    Jordan, S.
    LABORATORY INVESTIGATION, 2007, 87 : 232A - 232A
  • [4] DRAQ5-based, no-lyse, no-wash bone marrow aspirate evaluation by flow cytometry
    Allan, Robert W.
    Ansari-Lari, M. A.
    Jordan, Sandra
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2008, 129 (05) : 706 - 713
  • [5] A new no-lyse, no-wash flow-cytometric method for the determination of CD4 T cells in blood samples
    Greve, B
    Cassens, U
    Westerberg, C
    Jun, WG
    Sibrowski, W
    Reichelt, D
    Göhde, W
    TRANSFUSION MEDICINE AND HEMOTHERAPY, 2003, 30 (01) : 8 - 13
  • [6] Flow cytometry counting of CD34+ cells in whole blood
    Fornas, O
    Garcia, J
    Petriz, J
    NATURE MEDICINE, 2000, 6 (07) : 833 - +
  • [7] Flow cytometry counting of CD34+ cells in whole blood
    Oscar Fornas
    Joan Garcia
    Jordi Petriz
    Nature Medicine, 2000, 6 : 833 - 836
  • [8] A METHOD FOR ABSOLUTE QUANTIFICATION OF PLASMA CELLS BY FLOW CYTOMETRY USING A LYSE NO WASH PROCEDURE
    Kimlinger, Teresa K.
    Halling, Tim M.
    Rajkumar, S. Vincent
    Kumar, Shaji K.
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2009, 76B (06) : 401 - 401
  • [9] Comparison between a lyse-and-then-wash method and a lyse-non-wash technique for the enumeration of CD34+ hematopoietic progenitor cells
    Menéndez, P
    Redondo, O
    Rodriguez, A
    Lopez-Berges, MC
    Ercilla, G
    López, A
    Durán, A
    Almeida, J
    Pérez-Simón, JA
    San Miguel, JF
    Gratama, JW
    Orfao, A
    CYTOMETRY, 1998, 34 (06): : 264 - 271
  • [10] Real-time cytometric assay of nitric oxide and superoxide interaction in peripheral blood monocytes: A no-wash, no-lyse kinetic method
    Balaguer, Susana
    Diaz, Laura
    Gomes, Angela
    Herrera, Guadalupe
    O'Connor, Jose-Enrique
    Urios, Amparo
    Felipo, Vicente
    Montoliu, Carmina
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2017, 92 (03) : 211 - 217