Good results at 2-year follow-up of a custom-made triflange acetabular component for large acetabular defects and pelvic discontinuity: a prospective case series of 50 hips

被引:13
|
作者
Scharff-Baauw, Marieke [1 ,2 ,3 ]
Van Hooff, Miranda L. [1 ]
Van Hellemondt, Gijs G. [1 ]
Jutte, Paul C. [2 ]
Bulstra, Sjoerd K. [2 ]
Spruit, Maarten [1 ]
机构
[1] Sint Maartensklin, Dept Orthopaed, Nijmegen, Netherlands
[2] Univ Med Ctr Groningen, Dept Orthopaed, Groningen, Netherlands
[3] Univ Med Ctr Groningen, Dept Orthopaed, Leeuwarden, Netherlands
关键词
ARTHROPLASTY; RECONSTRUCTION; IMPLANT;
D O I
10.1080/17453674.2021.1885254
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose - Custom triflange acetabular components (CTACs) are suggested as good solutions for large acetabular defects in revision total hip arthroplasty. However, high complication rates have been reported and most studies are of limited quality. This prospective study evaluates the performance of a CTAC in patients with large acetabular defects including pelvic discontinuity. Patients and methods - Prospectively collected data of 49 consecutive patients (50 hips), who underwent an acetabular revision with a CTAC were analyzed. Follow-up (FU) was 2 years. The median age of the patients was 68 years (41-89) and 41 were women. Primary outcomes were re-revision of the CTAC and differences between the modified Oxford Hip Score (mOHS) preoperatively and at 2-year follow-up. Secondary outcomes included several patient-reported outcomes (PROMs), radiological results, complications, and a comparison between hips with and without pelvic discontinuity (PD). Results - 1 patient (1 hip) was lost to the 2-year FU. No CTAC needed re-revision. The preoperative and 2-year FU mOHS were available in 40 hips and improved statistically significantly. All of the other secondary outcomes improved over time. 5 hips (of 45 with radiological 2-year FU) had loosening of screws. 8 hips had complications, including 3 persistent wound leakage, 3 pelvic fractures, and 1 dislocation. The mOHS and complication rate were similar in hips with and without PD. Interpretation - Reconstruction of large acetabular defects with and without PD with this CTAC showed good improvement in patient-reported daily functioning, high patient-reported satisfaction, few complications, and no re-revisions at 2-year FU.
引用
收藏
页码:297 / 303
页数:7
相关论文
共 27 条
  • [1] Custom Triflange Acetabular Components for Large Acetabular Defects: Minimum 10-Year Follow-up
    Moore, K. David
    McClenny, Michelle D.
    Wills, Bradley W.
    ORTHOPEDICS, 2018, 41 (03) : E316 - E320
  • [2] Minced Cartilage Implantation in Acetabular Cartilage Defects: Case Series with 2-Year Results
    Gebhardt, Sebastian
    Hofer, Andre
    Wassilew, Georgi I.
    Sobau, Christian
    Zimmerer, Alexander
    CARTILAGE, 2023, 14 (04) : 393 - 399
  • [3] Custom-made triflanged implants in reconstruction of severe acetabular bone loss with pelvic discontinuity after total hip arthroplasty consecutive cohort study TWO TO 11 YEARS OF FOLLOW-UP
    Winther, S. S.
    Petersen, M.
    Yilmaz, M.
    Kaltoft, N. S.
    Sturup, J.
    Winther, N. S.
    BONE & JOINT OPEN, 2022, 3 (11): : 867 - 876
  • [4] Migration of the acetabular component after revision with impacted morselized allografts -: A radiostereometric 2-year follow-up analysis of 21 cases
    Ornstein, E
    Franzén, H
    Johnsson, R
    Sandquist, P
    Stefánsdóttir, A
    Sundberg, M
    ACTA ORTHOPAEDICA SCANDINAVICA, 1999, 70 (04): : 338 - 342
  • [5] The use of bilobed porous-coated acetabular components without structural bone graft for type III acetabular defects in revision total hip arthroplasty - A prospective study with a minimum 2-year follow-up
    Moskal, JT
    Shen, FH
    JOURNAL OF ARTHROPLASTY, 2004, 19 (07): : 867 - 873
  • [6] The use of an Ossis custom 3D-printed tri-flanged acetabular implant for major bone loss: minimum 2-year follow-up
    Kieser, David C.
    Ailabouni, Ramez
    Kieser, Sandra C. J.
    Wyatt, Michael C.
    Armour, Paul C.
    Coates, Mark H.
    Hooper, Gary J.
    HIP INTERNATIONAL, 2018, 28 (06) : 668 - 674
  • [7] Efficacy and tolerability of a custom-made Narval mandibular repositioning device for the treatment of obstructive sleep apnea: ORCADES study 2-year follow-up data
    Attali, Valerie
    Vecchierini, Marie-Francoise
    Collet, Jean-Marc
    d'Ortho, Marie-Pia
    Goutorbe, Frederic
    Kerbrat, Jean-Baptiste
    Leger, Damien
    Lavergne, Florent
    Monaca, Christelle
    Monteyrol, Pierre-Jean
    Morin, Laurent
    Mullens, Eric
    Pigearias, Bernard
    Martin, Francis
    Tordjman, Fabienne
    Khemliche, Hauria
    Lerousseau, Lionel
    Meurice, Jean-Claude
    Abedipour, Darius
    Allard-Redon, Aurelie
    Aranda, Alexandre
    Attali, Valerie
    Bavozet, Frederique
    Becu, Martine
    Beruben, Wally
    Bessard, Jerome
    Bonafe, Isabelle
    Boukhana, Mohammed
    Chabrol, Bruno
    Chatte, Gerard
    Chauvel-Lebret, Dominique
    Collet, Jean-Marc
    Coste, Olivier
    Dumont, Nathalie
    Durand-Amat, Sophie
    D'Ortho, Marie-Pia
    Elbaum, Jean-Marc
    Gallet De Santerre, Olivier
    Goutorbes, Frederic
    Grandjean, Thierry
    Guyot, Wilma
    Hammer, Doniphan
    Havasi, Carmen
    Huet, Pascal
    Kerbrat, Jean-Baptiste
    Khemliche, Hauria
    Koltes, Christian
    Leger, Damien
    Lacassagne, Laurent
    Laur, Xavier
    SLEEP MEDICINE, 2019, 63 : 64 - 74
  • [8] Multiple osteochondral arthroscopic grafting (mosaicplasty) for cartilage defects of the knee: Prospective study results at 2-year follow-up
    Marcacci, M
    Kon, E
    Zaffagnini, S
    Iacono, F
    Neri, MP
    Vascellari, A
    Visani, A
    Russo, A
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (04): : 462 - 470
  • [9] Bone mineral density changes in the graft after acetabular impaction bone grafting in primary and revision hip surgery A 2-year prospective follow-up
    Gerhardt, Davey M. J. M.
    De Visser, Enrico
    Hendrickx, Baudewijn W.
    Schreurs, Berend W.
    Van Susante, Job L. C.
    ACTA ORTHOPAEDICA, 2018, 89 (03) : 302 - 307
  • [10] A Mucogingival Technique for the Treatment of Multiple Recession Defects in the Mandibular Anterior Region: A Case Series with a 2-Year Follow-Up
    Bethaz, Nicola
    Romano, Federica
    Ferrarotti, Francesco
    Mariani, Giulia Maria
    Aimetti, Mario
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2014, 34 (03) : 345 - 352