Experimental investigation of the performance of two-stage evaporative coolers

被引:23
|
作者
AlJuwayhel, FI [1 ]
AlHaddad, AA [1 ]
Shaban, HI [1 ]
ElDessouky, HTA [1 ]
机构
[1] KUWAIT UNIV,FAC ENGN & PETR,DEPT CHEM ENGN,SAFAT 13060,KUWAIT
关键词
D O I
10.1080/01457639708939893
中图分类号
O414.1 [热力学];
学科分类号
摘要
Experiments have been conducted to investigate the thermal effectiveness and the air-side pressure drop of single- and two-stage evaporative coolers. Two different configurations of the two-stage evaporative cooler have been tested. The first one uses an external cooling tower to cool the water required to precool the air in the indirect water-to-air precooler. in the second design the cooled water in the direct-contact evaporative cooler is used as the cooling medium in the air precooler. The variables considered are packing thickness, mass flow rate of water to the precooler, and mass flux of water irrigating the packing. The data obtained indicate that the thermal effectiveness of the two-stage evaporative cooler with a cooling tower is high compared to that of the system without a cooling tower which in trim is superior to that of the single-stage, direct-contact evaporative cooler. Increasing the mass flow rate of water to the air precooler improves the effectiveness of the two-stage evaporative coolers. The effectiveness of the two-stage cooler without a cooling tower dimensions uniformly with the increase in the mass flux of water irrigating the packing. The effectiveness of the single-stage and the two-stage design using a cooling tower was found to be independent of the mass flux of water flowing over the packing For the three configurations tested, the thermal performance increases with the packing thickness, and the air-side pressure is nearly constant.
引用
收藏
页码:21 / 33
页数:13
相关论文
共 50 条
  • [1] Performance analysis of two-stage evaporative coolers
    El-Dessouky, H
    Ettouney, H
    Al-Zeefari, A
    [J]. CHEMICAL ENGINEERING JOURNAL, 2004, 102 (03) : 255 - 266
  • [2] Experimental and theoretical investigation of internal two-stage evaporative cooler
    Alklaibi, A. M.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2015, 95 : 140 - 148
  • [3] An experimental investigation on the integration of two-stage dehumidification and regenerative evaporative cooling
    La, D.
    Dai, Y. J.
    Li, Y.
    Tang, Z. Y.
    Ge, T. S.
    Wang, R. Z.
    [J]. APPLIED ENERGY, 2013, 102 : 1218 - 1228
  • [4] Performance analysis of a two-stage evaporative cooler
    Jaafarian, Mohammad
    Kazemian, Mohammad Ehsan
    [J]. MECHANICS & INDUSTRY, 2017, 18 (04)
  • [5] Numerical investigation of wet-bulb effectiveness and water consumption in one-and two-stage indirect evaporative coolers
    Moshari, Shahab
    Heidarinejad, Ghassem
    Fathipour, Aida
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2016, 108 : 309 - 321
  • [6] Analyses of the performance and polar characteristics of two-stage thermoelectric coolers
    Xuan, XC
    [J]. SEMICONDUCTOR SCIENCE AND TECHNOLOGY, 2002, 17 (05) : 414 - 420
  • [7] THE EXPERIMENTAL RESEARCH ON TWO-STAGE WATER EVAPORATIVE COOLING SYSTEM
    Zhang Qiang
    Liu Zhongbao
    Yang Shuang
    Ma Qingbo
    Liu Ting
    [J]. 2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [8] Experimental investigation of two-stage evaporative cooler powered by photovoltaic panels using underground water
    Mahdi, Ali Hammoodi
    Aljubury, Issam M. Ali
    [J]. JOURNAL OF BUILDING ENGINEERING, 2021, 44
  • [9] Experimental investigation of two-stage indirect/direct evaporative cooling system in various climatic conditions
    Heidarinejad, Ghassem
    Bozorgmehr, Mojtaba
    Delfani, Shahram
    Esmaeelian, Jafar
    [J]. BUILDING AND ENVIRONMENT, 2009, 44 (10) : 2073 - 2079
  • [10] Two-stage 4 K pulse tube coolers: Performance and application
    Wang, C
    Thummes, G
    Heiden, C
    [J]. CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR 98, 1998, : 51 - 54