Fingernail dosimetry using electron spin resonance for radiation disaster response

被引:3
|
作者
Gonzales, C. A. B. [1 ,2 ,5 ]
Yasuda, H. [2 ]
Hirota, S. [2 ]
Miki, K. [3 ]
Saito, A. [3 ]
Tano, J. E. [2 ,5 ]
Nagata, Y. [4 ]
机构
[1] Hiroshima Univ, Grad Sch Biomed & Hlth Sci, Dept Radiat Oncol, Minami Ku, Kasumi 1-2-3, Hiroshima 7348553, Japan
[2] Hiroshima Univ, RIRBM, Dept Radiat Biophys, Minami Ku, 1 Kasumi 2-3, Hiroshima 7348551, Japan
[3] Hiroshima Univ Hosp, Dept Radiat Oncol, Minami Ku, 1 Kasumi 2-3, Hiroshima 7348551, Japan
[4] Hiroshima Univ Hosp, Inst Biomed & Hlth Sci, Dept Radiat Oncol, Minami Ku, 1 Kasumi 2-3, Hiroshima 7348551, Japan
[5] Hiroshima Univ, Hiroshima Initiat Renaissance Radiat Disaster, Phoenix Leader Educ Program, Minami Ku, Kasumi 1-2-3, Hiroshima 7348553, Japan
关键词
EMERGENCY EPR DOSIMETRY; TOOTH ENAMEL DOSIMETRY; SEMIPALATINSK REGION; PART; SIGNALS; NAILS;
D O I
10.1088/1742-6596/1248/1/012072
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study investigates the use of electron spin resonance (ESR) signals from human fingernails for retrospective dosimetry as part of radiation disaster response, focusing on the variabilities of individual responses to radiation. Samples of fingernails were collected from 7 adult donors ( Asian type) and irradiated to 35 Gy and 70 Gy of gamma-rays from a Cs-137 source at a dose rate of 0.857 Gy/min. All irradiated fingernails were measured for 39 days with an X-band ESR spectrometer and stored in darkness inside the vacuum desiccator (30% humidity, 20 degrees C) in between measurements at all times. All samples were harvested using one specific nail cutter and given no other special treatments. It was observed that the measured radiation-induced signals faded on about 10-12% after 1 day of exposure. Though the signal intensities showed a significant difference among the donors, stronger linearities in the dose responses were observed in the samples of younger donors. From the results obtained in this study, it is expected that fingernails would be a useful tool for retrospective dosimetry in case of an unexpected radiological accident or medical treatment error associated with exposure in therapeutic dose range, as far as the individual-based calibration curves were available. Further investigations will be made to clarify the reason for the different responses by using the fingernail samples taken from a greater number of donors of different ages and lifestyles.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Retrospective dosimetry using fingernail electron paramagnetic resonance response
    Noori, Abbas
    Mostajaboddavati, Mojtaba
    Ziaie, Farhood
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2018, 50 (03) : 526 - 530
  • [2] ELECTRON-SPIN-RESONANCE DOSIMETRY USING HUMAN FINGERNAIL AND HAIR SAMPLES
    MILLER, SD
    KALKWARF, DR
    [J]. HEALTH PHYSICS, 1987, 52 : S69 - S69
  • [3] Effects of water on fingernail electron paramagnetic resonance dosimetry
    Zhang, Tengda
    Zhao, Zhixin
    Zhang, Haiying
    Zhai, Hezheng
    Ruan, Shuzhou
    Jiao, Ling
    Zhang, Wenyi
    [J]. JOURNAL OF RADIATION RESEARCH, 2016, 57 (05) : 460 - 467
  • [4] An alternative method using microwave power saturate in fingernail/electron paramagnetic resonance dosimetry
    Choi, Hoon
    Park, Byeongryong
    Choi, Muhyun
    Lee, Byungil
    Lee, Cheol Eui
    [J]. RADIATION PROTECTION DOSIMETRY, 2014, 159 (1-4) : 164 - 171
  • [5] Proton dosimetry in bone using electron spin resonance
    Copeland, JF
    Gall, KP
    Lee, SY
    Chabot, GE
    [J]. APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) : 1533 - 1538
  • [6] ELECTRON-SPIN-RESONANCE ALANINE DOSIMETRY APPLIED TO RADIATION PROCESSING
    MOSSE, DC
    [J]. RADIATION PHYSICS AND CHEMISTRY, 1988, 31 (4-6): : 413 - 417
  • [7] DOSIMETRY BY ELECTRON-SPIN-RESONANCE SPECTROSCOPY FOLLOWING A RADIATION ACCIDENT
    SAGSTUEN, E
    THEISEN, H
    HENRIKSEN, T
    [J]. HEALTH PHYSICS, 1983, 45 (05): : 961 - 968
  • [8] Electron spin resonance dosimetry of teeth of Goiania radiation accident victims
    Rossi, AM
    Wafcheck, CC
    de Jesus, EF
    Pelegrini, F
    [J]. APPLIED RADIATION AND ISOTOPES, 2000, 52 (05) : 1297 - 1303
  • [9] ELECTRON-SPIN-RESONANCE DOSIMETRY OF A-BOMB RADIATION USING TOOTH ENAMEL AND GRANITE ROCKS
    IKEYA, M
    MIKI, T
    KAI, A
    HOSHI, M
    [J]. RADIATION PROTECTION DOSIMETRY, 1986, 17 (1-4) : 181 - 184
  • [10] Radiation dosimetry in human bone using electron paramagnetic resonance
    Breen, SL
    Battista, JJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (12): : 2065 - 2077