LigaSure vs clamp-and-tie technique to achieve hemostasis in total thyroidectomy for benign multinodular goiter -: A prospective randomized study

被引:63
|
作者
Saint Marc, Olivier
Cogliandolo, Andrea
Piquard, Arnaud
Fama, Fausto
Pidoto, Rocco Roberto
机构
[1] Ctr Hosp Reg Orleans, Serv Chirurg Digest Endocrinienne & Thorac, F-45067 Orleans 2, France
[2] Univ Messina, Dept Gen Surg, Messina, Italy
关键词
D O I
10.1001/archsurg.142.2.150
中图分类号
R61 [外科手术学];
学科分类号
摘要
Hypothesis: Occurrence of adverse effects and advantages of the LigaSure diathermy system (or LigaSure vessel sealing system) in total thyroidectomy have not been tested in prospective randomized studies comparing its use with that of the time-saving clamp-and-tie technique to ligate and divide thyroid vessels. The effectiveness of LigaSure in achieving vessel division and hemostasis remains dependent on vessel diameter, and the risk of damage to adjacent structures cannot be completely excluded. We tested the hypothesis that use of LigaSure compared with the clamp-and-tie technique can significantly and conveniently reduce operative time without increasing postoperative complications in patients undergoing total thyroidectomy. for benign multinodular goiter. Design: Prospective randomized study. Setting: Regional hospital. Patients: Two hundred consecutive patients with benign multinodular goiter undergoing total thyroidectomy performed by 1 of 3 surgeons. Interventions: According to a randomized sequence, total thyroidectomy was performed in 100 patients using LigaSure and in 100 patients using the clamp-and-tie technique. Main Outcome Measures: End points of the study included the comparative evaluation of postoperative complications, need for parathyroid gland auto transplantation, operative time, and time to hospital discharge. Preoperative, postoperative (24 hours), and 6-week follow-up serum Ca++ levels are also reported and compared. Results: The postoperative complication rate was 35% overall, including all transient postoperative disturbances. The incidence of cervical hematomas was 2%, but 3 patients (1.5%), 1 in the LigaSure group and 2 in the clamp-and-tie group, required repeat operations because of respiratory tract obstruction. The incidence of permanent complications was 2.5% overall, including 3 patients (1.5%) with permanent hypocalcemia and 2 patients (1%) with permanent recurrent nerve lesions. No statistical difference in the incidence of complications was found between the 2 study groups. Similarly, no difference was found in mean hospitalization time and need for parathyroid gland autotransplantation. Preoperative, postoperative, and 6-week follow-up mean serum Ca++ levels were not statistically different in the 2 study groups and in the subset of patients undergoing parathyroid gland autotransplantation. Mean operative time was significantly shorter in the LigaSure group, although the mean difference between the 2 study groups was minimal (7.4 minutes). Concomitantly, there was an additional cost of 45E (US $57.40) per operation using LigaSure. Conclusion: The use of LigaSure is equally as safe and effective at vessel division and homeostasis as the clamp-and-tie technique, with a statistically significant (although minimal) decrease in mean operative time. Because of this minimal decrease in operative time, use of LigaSure would allow more patients to undergo total thyroidectomy each year, which would eventually help to offset its higher cost.
引用
收藏
页码:150 / 156
页数:7
相关论文
共 39 条
  • [1] LigaSure vs clamp-and-tie technique to achieve hemostasis in total thyroidectomy for benign multinodular goiter - A prospective randomized study - Invited critique
    Prinz, Richard A.
    Nilubol, Naris
    Patel, Subhash
    [J]. ARCHIVES OF SURGERY, 2007, 142 (02) : 157 - 157
  • [2] Ligasure versus clamp-and-tie thyroidectomy for benign nodular disease
    Petrakis, LE
    Kogerakis, NE
    Lasithiotakis, KG
    Vrachassotakis, N
    Chalkiadakis, GE
    [J]. HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2004, 26 (10): : 903 - 909
  • [3] A comparison of the outcome using Ligasure™ small jaw and clamp-and-tie technique in thyroidectomy: a randomized single center study
    S. Coiro
    F. M. Frattaroli
    F. De Lucia
    E. Manna
    F. Fabi
    J. M. Frattaroli
    G. Pappalardo
    [J]. Langenbeck's Archives of Surgery, 2015, 400 : 247 - 252
  • [4] A comparison of the outcome using Ligasure™ small jaw and clamp-and-tie technique in thyroidectomy: a randomized single center study
    Coiro, S.
    Frattaroli, F. M.
    De Lucia, F.
    Manna, E.
    Fabi, F.
    Frattaroli, J. M.
    Pappalardo, G.
    [J]. LANGENBECKS ARCHIVES OF SURGERY, 2015, 400 (02) : 247 - 252
  • [5] Randomized clinical trial on Harmonic Focus shears versus clamp-and-tie technique for total thyroidectomy
    Mourad, Michel
    Rulli, Francesco
    Robert, Annie
    Scholtes, Jean Louis
    De Meyer, Martine
    De Pauw, Luc
    [J]. AMERICAN JOURNAL OF SURGERY, 2011, 202 (02): : 168 - 174
  • [6] Comparison of hypocalcemia rates between LigaSure and clamp-and-tie hemostatic technique in total thyroidectomies
    Chiang, Feng-Yu
    Lee, Kang Dae
    Tae, Kyung
    Tufano, Ralph P.
    Wu, Che-Wei
    Lu, I-Cheng
    Chang, Pi-Ying
    Lin, Yi-Chu
    Huang, Tzu-Yen
    [J]. HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2019, 41 (10): : 3677 - 3683
  • [7] Differences in Surgical Outcome in Near Total Thyroidectomy for Benign Nodular Goiter: A Comparison of LigaSure Vessel Sealer versus Conventional Clamp Knot Tie Technique
    Shaikh, Shiraz
    Sushel, Champa
    Laghari, Ahsan Ali
    Laghari, Qamber Ali
    Laghari, Zameer Hussain
    Memon, Aisha
    [J]. JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2021, 33 (30B) : 65 - 69
  • [8] Prospective Randomized Trial of Ligasure Versus Harmonic Hemostasis Technique in Thyroidectomy
    Reza Rahbari
    Aarti Mathur
    Mio Kitano
    Marlon Guerrero
    Wen T. Shen
    Quan-Yang Duh
    Orlo H. Clark
    Electron Kebebew
    [J]. Annals of Surgical Oncology, 2011, 18 : 1023 - 1027
  • [9] Prospective Randomized Trial of Ligasure Versus Harmonic Hemostasis Technique in Thyroidectomy
    Rahbari, Reza
    Mathur, Aarti
    Kitano, Mio
    Guerrero, Marlon
    Shen, Wen T.
    Duh, Quan-Yang
    Clark, Orlo H.
    Kebebew, Electron
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2011, 18 (04) : 1023 - 1027
  • [10] Safely increasing the efficiency of thyroidectomy using a new bipolar electrosealing device (LigaSure™) versus conventional clamp-and-tie technique
    Franko, J
    Kish, KJ
    Pezzi, CM
    Pak, H
    Kukora, JS
    [J]. AMERICAN SURGEON, 2006, 72 (02) : 132 - 136