High Voltage Ride through Strategy of Wind Farm Considering Generator Terminal Voltage Distribution

被引:0
|
作者
Qin, Yanhui [1 ,2 ]
Cao, Zeyu [1 ]
Yang, Zhichao [1 ]
Gao, Bingtuan [1 ]
Dong, Xuetao [2 ]
机构
[1] Southeast Univ, Sch Elect Engn, Nanjing 210096, Peoples R China
[2] Xinjiang Elect Power Res Inst, Urumqi 830000, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 03期
关键词
wind power transmission; DC blocking; doubly fed induction generator; synchronous condenser; high voltage ride through;
D O I
10.3390/app11031248
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
When wind power is transmitted via high-voltage direct current (HVDC), the problem of high-voltage ride-through (HVRT), caused by direct-current (DC) blocking must be seriously taken into account. All the wind turbines in a wind farm are usually equivalent to a single turbine in the existing research on HVRT, which ignores the generator terminal voltage distribution in a wind farm. In view of the fact that the severity of fault voltage felt by each wind turbine in the field is different, an improved HVRT strategy considering voltage distribution is proposed in this article. First, this article analyzes the mechanism of voltage swell failure caused by DC blocking, and the characteristics of the generator terminal voltage distribution in wind farms. Second, the reactive power characteristic equations of the synchronous condenser and the doubly-fed induction generator (DFIG) are derived. Third, based on the extraction of the key node voltage, this article takes the key node voltage as the compensation target, and put forwards a HVRT strategy combining the synchronous condenser and wind turbine. Finally, the simulation is carried out to demonstrate the effectiveness of the proposed strategy in improving the HVRT capability of all wind turbines.
引用
收藏
页码:1 / 17
页数:17
相关论文
共 50 条
  • [1] Low Voltage Ride-through Strategy for Wind Farm and VSC-HVDC
    Niu, Lele
    Wang, Xiao
    Wu, Linlin
    Yan, Feng
    Xu, Man
    Hu, Xiaobao
    [J]. 2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 2183 - 2188
  • [2] Coordinated control by ADRC strategy for a wind farm based on SCIG considering low voltage ride-through capability
    Laghridat, Hammadi
    Essadki, Ahmed
    Nasser, Tamou
    [J]. PROTECTION AND CONTROL OF MODERN POWER SYSTEMS, 2022, 7 (01)
  • [3] Coordinated control by ADRC strategy for a wind farm based on SCIG considering low voltage ride-through capability
    Hammadi Laghridat
    Ahmed Essadki
    Tamou Nasser
    [J]. Protection and Control of Modern Power Systems, 2022, 7
  • [4] Safety Voltage Control Strategy for High Voltage Ride-Through of Doubly Fed Induction Generator (DFIG)
    He Zehua
    [J]. PROCEEDINGS OF THE 2015 INTERNATIONAL POWER, ELECTRONICS AND MATERIALS ENGINEERING CONFERENCE, 2015, 17 : 562 - 566
  • [5] Reactive Voltage Control Strategy for PMSG-Based Wind Farm Considering Reactive Power Adequacy and Terminal Voltage Balance
    Dai, Jianfeng
    Wan, Lei
    Chang, Ping
    Liu, Lin
    Zhou, Xia
    [J]. ELECTRONICS, 2022, 11 (11)
  • [6] Wind Turbine Generator Low Voltage Ride through Requirements and Solutions
    Joos, G.
    [J]. 2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 1470 - 1476
  • [7] Voltage quality assessment considering low voltage ride-through requirement for wind turbines
    Park, Chang-Hyun
    Jang, Gilsoo
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (16) : 4205 - 4212
  • [8] Reactive power and voltage coordinated control strategy of wind farm considering transient voltage security
    Lu, Jinling
    He, Zhenmin
    He, Tongxiang
    Wei, Fangyuan
    Xu, Chao
    [J]. Dianwang Jishu/Power System Technology, 2015, 39 (10): : 2780 - 2786
  • [9] Single-phase PV generator model for distribution feeders considering voltage ride through conditions
    Queiroz, Luann Georgy Oliveira
    Batista, Oureste Elias
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2023, 223
  • [10] Low voltage ride through control strategy of photovoltaic inverter considering voltage fault type
    Ouyang S.
    Ma W.
    [J]. Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2018, 38 (09): : 21 - 26