Calculation of wind-driven cross ventilation in buildings with large openings

被引:83
|
作者
Seifert, Joachim [1 ]
Li, Yuguo
Axley, James
Roesler, Markus
机构
[1] Tech Univ Dresden, Inst Thermodynam & Bldg Energy Syst, D-8027 Dresden, Germany
[2] Univ Hong Kong, Dept Mech Engn, Hong Kong, Hong Kong, Peoples R China
[3] Yale Univ, Sch Architecture, New Haven, CT USA
关键词
natural ventilation; large openings; computational fluid dynamics; macroscopic model; stream tube;
D O I
10.1016/j.jweia.2006.04.002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A simplified macroscopic method is commonly used for wind-driven ventilation analysis of buildings with small openings. Consequently, it is reasonable to question if and under what conditions will this method provide accurate results in predicting ventilation flow rates in buildings with large openings. We investigate a single-zone cubic building with two equal large openings using a computational fluid dynamics approach. We analyzed the driving forces and the ventilation flow rates due to wind as a function of the geometry, size and relative location of the two openings. The ventilation flow rates are found to be affected by both wind flows around and through the building when the two openings are relatively large. The simplified macroscopic method can provide reasonable engineering accuracy (i.e., less than 10% error) when the porosity of the building envelope does not exceed a critical value. This critical value is not a constant; instead it depends significantly on the degree of alignment between the wind direction and the character of the dominant stream tube associated with the flow through the room. We found that the simplified macroscopic method fails to provide acceptable accuracy when this stream tube is truly dominant and parallel to the wind direction. The effects of wall thickness and aspect ratio of openings are also investigated. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:925 / 947
页数:23
相关论文
共 50 条
  • [1] Comparison of analysis methods for wind-driven cross ventilation through large openings
    Gautam, Khem Raj
    Rong, Li
    Zhang, Guoqiang
    Abkar, Mahdi
    [J]. BUILDING AND ENVIRONMENT, 2019, 154 : 375 - 388
  • [2] Wind-driven cross ventilation in long buildings
    Chu, Chia-Ren
    Chiang, Bo-Fan
    [J]. BUILDING AND ENVIRONMENT, 2014, 80 : 150 - 158
  • [3] Wind-driven natural ventilation for buildings with two openings on the same external wall
    Chu, Chia-Ren
    Chiu, Y. -H.
    Tsai, Yi-Ting
    Wu, Si-Lei
    [J]. ENERGY AND BUILDINGS, 2015, 108 : 365 - 372
  • [4] An experimental study of wind-driven cross ventilation in partitioned buildings
    Chu, Chia Ren
    Chiu, Y. -H.
    Wang, Yu-Wen
    [J]. ENERGY AND BUILDINGS, 2010, 42 (05) : 667 - 673
  • [5] The loss factors of building openings for wind-driven ventilation
    Chu, Chia-Ren
    Wang, Yu-Wen
    [J]. BUILDING AND ENVIRONMENT, 2010, 45 (10) : 2273 - 2279
  • [6] Wind-driven cross ventilation with internal obstacles
    Chu, Chia-Ren
    Chiang, Bo-Fan
    [J]. ENERGY AND BUILDINGS, 2013, 67 : 201 - 209
  • [7] The effect of louver blinds on the wind-driven cross ventilation of multi-storey buildings
    Jiang, Fujian
    Tao, Shiwen
    Tao, Qiuhua
    Li, Zhengrong
    Yuan, Yanping
    Zheng, Jianwen
    [J]. JOURNAL OF BUILDING ENGINEERING, 2022, 54
  • [8] Resistance property and ventilation rate calculation of buildings with large openings
    Gong Guangcai
    Bai Yu
    Li Hongxiang
    Han Bing
    [J]. PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 6, PTS A AND B, 2006, 6 : 2107 - 2112
  • [9] Effect of Opening Size on Wind-Driven Cross Ventilation
    Moey, Lip Kean
    Sing, Yao Horng
    Tai, Vin Cent
    Go, Tze Fong
    Sia, Yaw Yoong
    [J]. INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2021, 13 (06): : 99 - 108
  • [10] Parametric analysis of the wind-driven ventilation potential of buildings with rectangular layout
    Ferrucci, Margherita
    Brocato, Maurizio
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2019, 40 (01): : 109 - 128