Combined MR lymphangiography and MR imaging-guided needle localization of sentinel lymph nodes using gadomer-17

被引:13
|
作者
Torchia, MG
Misselwitz, B
机构
[1] Univ Manitoba, St Boniface Gen Hosp, Dept Surg, Winnipeg, MB R2H 2A6, Canada
[2] Univ Manitoba, Dept Human Anat & Cell Sci, Winnipeg, MB R3E 3J7, Canada
[3] Schering AG, Contrast Media Res, D-13342 Berlin, Germany
关键词
D O I
10.2214/ajr.179.6.1791561
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The goals of our study were to determine the technical feasibility of dynamic MR lymphangiography for detecting sentinel lymph nodes using Gadomer-17 contrast material to compare these results to the clinically standardized blue dye contrast agent, and to show MR imaging-guided needle localization marking of the sentinel nodes. MATERIALS AND METHODS. Six anesthetized swine underwent MR imaging before and for 1 hr after interstitial injection of Gadomer-17 in the posterior tongue and intradermally in the stifle (knee). Using MR imaging guidance, we percutancously placed a histology needle into the sentinel node or nodes. A standardized intraoperative sentinel node detection procedure was then performed using isosulfan blue contrast agent. Sentinel nodes identified on the MR images were compared with and matched to those identified by biopsy needle localization and the isosulfan blue contrast agent. RESULTS. Interstitial and intradermal injection of Gadomer-17 resulted in a lasting, increased MR signal in the regional lymph nodes. Seven sentinel nodes were identified in both the neck and the groin, with one pig showing two sentinel nodes in the neck and another showing two sentinel nodes in the groin. In all cases, the isosulfan blue contrast agent agreed with the location of the sentinel node determined by Gadomer-17 and marked with the needle. CONCLUSION. In this large animal model, dynamic MR angiography of sentinel lymph nodes is technically feasible using a contrast agent (Gadomer-17) and can be easily combined with MR imaging-guided needle localization.
引用
收藏
页码:1561 / 1565
页数:5
相关论文
共 50 条
  • [1] Interstitial MR lymphangiography for the detection of sentinel lymph nodes
    Torchia, MG
    Nason, R
    Danzinger, R
    Lewis, JM
    Thliveris, JA
    JOURNAL OF SURGICAL ONCOLOGY, 2001, 78 (03) : 151 - 156
  • [2] Interstitial MR lymphangiography for the detection of sentinel lymph nodes - Commentary
    Tanis, PJ
    Kroon, BR
    Nieweg, OE
    JOURNAL OF SURGICAL ONCOLOGY, 2001, 78 (03) : 157 - 157
  • [3] Contrast-enhanced MR imaging of coronary arteries with gadomer-17: Preliminary results
    Herborn, CU
    Barkhausen, J
    Shamsi, K
    Mahler, M
    Nagel, E
    RADIOLOGY, 2002, 225 : 353 - 353
  • [4] Preoperative MR imaging-guided needle localization of breast lesions
    Morris, EA
    Liberman, L
    Dershaw, DD
    Kaplan, JB
    LaTrenta, LR
    Abramson, AF
    Ballon, DJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (05) : 1211 - 1220
  • [5] Interstitial T1-weighted MR lymph fistulography with Gadomer-17 in an experimental animal model
    Staatz, G
    Spüntrup, E
    Bücker, A
    Vazquez-Jimenez, J
    Liakopoulos, OJ
    Pflüger, D
    Grosskortenhaus, S
    Misselwitz, B
    Günther, RW
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (02): : 275 - 281
  • [6] MR imaging-guided biopsy and localization of the breast
    Fischer, U
    Rodenwaldt, J
    Hundertmark, C
    Doler, W
    Grabbe, E
    RADIOLOGE, 1997, 37 (09): : 692 - 701
  • [7] MR Imaging-Guided biopsy and localization of the breast
    U. Fischer
    J. Rodenwaldt
    C. Hundertmark
    W. Döler
    E. Grabbe
    Der Radiologe, 1997, 37 : 692 - 701
  • [8] Comparison of Gadomer-17 and gadopentetate dimeglumine for differentiation of benign from malignant breast tumors with MR imaging
    Daldrup-Link, HE
    Shames, DM
    Wendland, M
    Mühler, A
    Gossmann, A
    Rosenau, W
    Brasch, RC
    ACADEMIC RADIOLOGY, 2000, 7 (11) : 934 - 944
  • [9] MR lymphangiography: Imaging strategies to optimize the imaging of lymph nodes with ferumoxtran-10
    Harisinghani, MG
    Dixon, WT
    Saksena, MA
    Brachtel, E
    Blezek, DJ
    Dhawale, PJ
    Torabi, M
    Hahn, PF
    RADIOGRAPHICS, 2004, 24 (03) : 867 - 878
  • [10] Precision of MR imaging-guided needle placement: Experimental results
    Langen, HJ
    Kugel, H
    Krahe, T
    Heindel, W
    Gieseke, J
    Lackner, K
    RADIOLOGY, 1996, 201 : 1249 - 1249