Statistical LOR estimation for a high-resolution dMiCE PET detector

被引:16
|
作者
Champley, Kyle M. [1 ]
Lewellen, Thomas K. [1 ]
MacDonald, Lawrence R. [1 ]
Miyaoka, Robert S. [1 ]
Kinahan, Paul E. [1 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2009年 / 54卷 / 20期
关键词
WAVELENGTH SHIFTING WLS; DEPTH; READOUT; MODULES; CALIBRATION; DESIGN;
D O I
10.1088/0031-9155/54/20/022
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We develop a statistical line of response (LOR) estimator of the three-dimensional interaction positions of a pair of annihilation photons in a PET detector module with depth of interaction capability. The three-dimensional points of interaction of a coincidence pair of photons within the detector module are estimated by calculation of an expectation of the points of interaction conditioned on the signals measured by the photosensors. This conditional expectation is computed from estimates of the probability density function of the light collection process and a model of the kinetics of photon interactions in the detector module. Our algorithm is capable of handling coincidences where each annihilation photon interacts any number of times within the detector module before being completely absorbed or escaping. In the case of multiple interactions, our algorithm estimates the position of the first interaction for each of the coincidence photons. This LOR estimation algorithm is developed for a high-resolution PET detector capable of providing depth-of-interaction information. Depth of interaction is measured by tailoring the light shared between two adjacent detector elements. These light-sharing crystal pairs are referred to as dMiCE and are being developed in our lab. Each detector element in the prototype system has a 2 x 2 mm(2) cross section and is directly coupled to a micro-pixel avalanche photodiode (MAPD). In this set-up, the distribution of the ratio of light shared between two adjacent detector elements can be expressed as a function of the depth of interaction. Monte Carlo experiments are performed using our LOR estimation algorithm and compared with Anger logic. We show that our LOR estimation algorithm provides a significant improvement over Anger logic under a variety of parameters.
引用
收藏
页码:6369 / 6382
页数:14
相关论文
共 50 条
  • [1] Statistical Three-Dimensional Positioning Algorithm for High-Resolution dMiCE PET Detector
    Champley, Kyle M.
    Lewellen, Thomas K.
    MacDonald, Lawrence R.
    Miyaoka, Robert S.
    Kinahan, Paul E.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4024 - 4027
  • [2] Accelerating Statistical LOR Estimation for a High-Resolution PET Scanner using FPGA Devices and a High Level Synthesis Tool
    Chen, Zhong-Ho
    Su, Alvin W. Y.
    Sun, Ming-Ting
    Hauck, Scott
    2011 IEEE 19TH ANNUAL INTERNATIONAL SYMPOSIUM ON FIELD-PROGRAMMABLE CUSTOM COMPUTING MACHINES (FCCM), 2011, : 105 - 108
  • [3] Investigation of a high-resolution detector for wholebody PET imaging
    Surti, Suleman
    Kuhn, Austin
    Karp, Joel S.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1601 - 1605
  • [4] A high-resolution PET detector based on continuous scintillators
    Tavernier, S
    Bruyndonckx, P
    Leonard, S
    Devroede, O
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 537 (1-2): : 321 - 325
  • [5] A Prototype Detector for a Novel High-Resolution PET System: BazookaPET
    Park, Ryeojin
    Miller, Brian W.
    Jha, Abhinav K.
    Furenlid, Lars R.
    Hunter, William C. J.
    Barrett, Harrison H.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2123 - 2127
  • [6] High-resolution PET detector design: modelling components of intrinsic spatial resolution
    Stickel, JR
    Cherry, SR
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (02): : 179 - 195
  • [7] DMice - a depth-of-interaction detector design for PET scanners
    Lewellen, TK
    Janes, M
    Miyaoka, RS
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2388 - 2392
  • [8] Online detector response calculations for high-resolution PET image reconstruction
    Pratx, Guillem
    Levin, Craig
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (13): : 4023 - 4040
  • [9] DETECTOR, SHIELDING AND GEOMETRIC DESIGN FACTORS FOR A HIGH-RESOLUTION PET SYSTEM
    DIGBY, WM
    DAHLBOM, M
    HOFFMAN, EJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) : 664 - 670
  • [10] Development and initial characterization of a high-resolution PET detector module with DOI
    Li, Mohan
    Wang, Yuli
    Abbaszadeh, Shiva
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (06):