Bone strains around immediately loaded implants supporting mandibular overdentures in human cadavers

被引:0
|
作者
Akca, Kivanc
Akkocaoglu, Murat
Comert, Ayhan
Tekdemir, Ibrahim
Cehreli, Murat Cavit
机构
[1] Hacettepe Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
[2] Hacettepe Univ, Fac Dent, Dept Oral Surg, Ankara, Turkey
[3] Ankara Univ, Sch Med, Dept Anat, Ankara, Turkey
关键词
biomechanics; dental implants; immediate loading; mandibular overdentures; micromovement; resonance frequency analysis; strain gauges;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the biomechanical effect of splinted versus unsplinted mandibular implants supporting overdentures subjected to experimental static immediate load on bone tissue deformation using strain gauge analysis. Materials and Methods: Strain gauges were bonded on the labial cortical bone adjacent to 2 Straumann dental implants placed in the mandibular interforaminal region of 4 completely edentulous mandibles of fresh human cadavers. The installation torque value (ITV) of each implant was measured using a custom-made torque wrench, and implant stability quotients (ISQs) were also obtained using resonance frequency analysis. Three overdentures (ODs), 2 splinted (bar-and cantilevered bar-retained) and 1 unsplinted (ball-retained), were fabricated for each edentulous mandible. Two experimental loads were applied subsequently via 2 miniature load cells that were placed bilaterally 10 mm (anterior loading) and 15 mm (posterior loading) from the implant. Strain measurements were performed at a sample rate of 10 KHz and under a maximum experimental static load of 100 N; they were simultaneously monitored from a computer connected to a data acquisition system. Finally, the removal torque values (RTV) of the implants were measured. Results: Strains on the labial cortical bone around implants supporting mandibular ODs under anterior loading were significantly higher than measured under posterior loading for all attachment types (P <.05). All strain values were compressive in nature, and the minimum strain (-19 mu epsilon) was recorded for bar-retained ODs under 25 N posterior loading, while the maximum strain (-797 mu epsilon) was for recorded for retentive anchor-retained ODs under 100 N anterior loading. Nonparametric correlations between ISQs, ITVs, and RTVs identified significant correlations only for ITVs and RTVs (P <.05). Conclusion: Splinting of 2 interforaminal dental implants, regardless of attachment type, to support mandibular ODs subjected to immediate load significantly reduced initial bone tissue strains experienced on the labial cortical bone in comparison with the use of unsplinted implants.
引用
收藏
页码:101 / 109
页数:9
相关论文
共 50 条
  • [1] Human ex vivo bone tissue strains around immediately loaded implants supporting maxillary overdentures
    Akça, K
    Akkocaoglu, M
    Cömert, A
    Tekdemir, I
    Çehreli, MC
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (06) : 715 - 722
  • [2] Human Ex Vivo Bone Tissue Strains Around Immediately-Loaded Implants Supporting Mandibular Fixed Prostheses
    Koekat, Ali Murat
    Coemert, Ayhan
    Tekdemir, Ibrahim
    Akkocaoglu, Murat
    Akca, Kivanc
    Cehreli, Murat Cavit
    [J]. IMPLANT DENTISTRY, 2009, 18 (02) : 162 - 171
  • [3] Radiographic assessment of changes in marginal bone around endosseous implants supporting mandibular overdentures
    Batenburg, RHK
    Meijer, HJA
    Geraets, WGM
    van der Stelt, PF
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 1998, 27 (04) : 221 - 224
  • [4] Retrospective study of 200 immediately loaded implants retaining 50 mandibular overdentures
    Degidi, Marco
    Piattelli, Adriano
    Iezzi, Giovanna
    Carinci, Francesco
    [J]. QUINTESSENCE INTERNATIONAL, 2007, 38 (04): : 281 - 288
  • [5] Effects of attachment design on strains around implants supporting overdentures
    Cekic, Cihat
    Akca, Kivanc
    Cehreli, Murat C.
    [J]. QUINTESSENCE INTERNATIONAL, 2007, 38 (06): : E291 - E297
  • [6] Immediately loaded mini-implants supporting mandibular overdentures: A one-year comparative prospective cohort study
    Mifsud, David P.
    Sammut, Edward J.
    Degiorgio, Jan
    Borg, Peter
    Cortes, Arthur R. G.
    Attard, Nikolai J.
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (04) : 507 - 513
  • [7] Five-Year Clinical Results of Immediately Loaded Dental Implants Using Mandibular Overdentures
    Alfadda, Sara A.
    Attard, Nikolai J.
    David, Lesley A.
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2009, 22 (04) : 368 - 373
  • [8] Radiographic evaluation of bone density around immediately loaded implants
    Hasan, Istabrak
    Dominiak, Marzena
    Blaszczyszyn, Artur
    Bourauel, Christoph
    Gedrange, Tomasz
    Heinemann, Friedhelm
    [J]. ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2015, 199 : 52 - 57
  • [9] Circumferential bone loss around splinted and nonsplinted immediately loaded implants retaining mandibular overdentures: A randomized controlled clinical trial using cone beam computed tomography
    Elsyad, Moustafa Abdou
    Khirallah, Ahmed Samir
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (05): : 741 - 748
  • [10] Resilient Stud Versus Bar Attachments for Immediately Loaded Implants Supporting Mandibular Overdentures: 1-year Randomized Controlled Clinical Trial
    Elsyad, Moustafa Abdou
    Alsabri, Mohammed Abdullah
    Elgamal, Mohamed
    Al-Tonbary, Gilan Youssef
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (02) : 346 - 354