Influence of the diaphragm wall on the earthquake responses of the underground station structure under two different connection types

被引:0
|
作者
Zhuang, H. [1 ]
Wang, X. [1 ]
Fu, J. [1 ]
Chen, S. [2 ]
Chen, G. [1 ]
机构
[1] Nanjing Tech Univ, Inst Geotech Engn, Nanjing, Jiangsu, Peoples R China
[2] China Earthquake Adm, Inst Geophys, Beijing, Peoples R China
关键词
PLASTIC-DAMAGE MODEL; SEISMIC RESPONSE; SUBWAY STATION;
D O I
暂无
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Two types of connection methods are often used to connect the diaphragm wall with the side wall of underground subway station. In this paper, the different seismic response of underground subway station caused by different connection types is studied by the finite element method. As a result, the connection types between the diaphragm wall and the subway station have great influence on the seismic response of the underground station structure, such as the interlayer displacement angles, the lateral displacement response, the seismic damages of structure, and so on. The tie connection type should greatly increase the lateral resisting stiffness of the underground subway station, which should alleviate its seismic damages as a whole. However, the tie connection type should also aggravate the earthquake damages of the top and bottom plates near to the side wall. The above findings should be recognized in the seismic design of underground subway station.
引用
收藏
页码:5897 / 5904
页数:8
相关论文
共 30 条
  • [1] Effect of diaphragm wall on earthquake responses of an underground subway station
    Wang X.-J.
    Zhuang H.-Y.
    Chen G.-X.
    Wang R.
    Zhuang, Hai-Yang (zhuang7802@163.com), 1600, Chinese Society of Civil Engineering (39): : 1435 - 1443
  • [2] Seismic performance of underground subway station structure considering connection modes and diaphragm wall
    Zhuang Haiyang
    Yang Jing
    Chen Su
    Fu Jisai
    Chen Guoxing
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2019, 127
  • [3] The response analysis of underground railway station structure in soft soil under strong earthquake
    Zhao, Boming
    Jiang, Yingli
    Chen, Jing
    Zhongguo Tiedao Kexue/China Railway Science, 2009, 30 (03): : 45 - 50
  • [4] Influence of diaphragm wall on seismic responses of large unequal-span subway station in liquefiable soils
    Wang, Jianning
    Ma, Guowei
    Zhuang, Haiyang
    Dou, Yuanming
    Fu, Jisai
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2019, 91
  • [5] Effect of connection modes on seismic responses of a diaphragm wall-subway station system subjected to mainshock-aftershock sequences
    Zhang, Long-Ji
    Cui, Zhen-Dong
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2024, 186
  • [6] Influence of earthquake types on the design of seismic-resistant steel structures - Part 2: Structural responses for different earthquake types
    Gioncu, V.
    Mazzolani, F. M.
    Stessa 2006, 2006, : 121 - 127
  • [7] A Simplified Method for Evaluating the Diaphragm Flexibility for Frame-Shear Wall Structure under Earthquake Load
    Huang, Yuan
    Zhang, Xiaoli
    Wang, Lizhuan
    Hu, Xiaofang
    BUILDINGS, 2023, 13 (02)
  • [8] Different structure of the coronary wall in two types of hypertension: NO deficiency and SHR.
    Kristek, F
    BIOLOGY OF NITRIC OXIDE, PT 7, 2000, 16 : 69 - 69
  • [9] Seismic performance of two-story and three-span underground subway station structure under different foundation isolation cases
    Zhang G.
    Zhuang H.
    Xu Z.
    Wang J.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2023, 42 (11): : 27 - 41
  • [10] STRUCTURAL PERFORMANCE OF TWO TYPES OF WALL SLAB CONNECTION UNDER OUT-OF-PLANE LATERAL CYCLIC LOADING
    Al-Aghbari, Ahmed Abdulrazzaq Nasser
    Hamzah, Siti Hawa
    Hamid, Nor Hayati Abdul
    Rahman, Nurhaniza Abdul
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2012, 7 (02) : 177 - 194