Chinese weight-correction model for maternal serum markers in Down syndrome prenatal screening

被引:2
|
作者
Wang, Yuan-Yuan
Zhang, Li
Peng, Zuo-Qi
Cui, Qin-Zi
Ma, Xu
机构
[1] Natl Res Inst Family Planning, Beijing 100081, Peoples R China
[2] Peking Union Med Coll, Beijing, Peoples R China
[3] WHO Collaborating Ctr Res Human Reprod, Beijing, Peoples R China
[4] Sheng Yang Maternal & Child Hlth Hosp, Liaoning, Peoples R China
关键词
Down syndrome; prenatal screening; regression model; weight-correction model;
D O I
10.1016/j.ijgo.2006.11.013
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To determine the best weight-correction model by means of analyzing the relationship between maternal weight and maternal serum markers when screening for Down syndrome in China. Methods: Serum levels of (x-fetoprotein (AFP) and free beta-human chorionic gonadotropin (hCG) were measured in 35,917 Chinese women during the second semester of a normal singleton pregnancy and converted to multiple of median (MoM) values. Using 2 methods of statistical analysis, the all-point method and the median regression method, 4 weightcorrection models were then tried, the simple linear, reciprocal, quadratic, and log-linear regression models. Results: The median regression method performed better than the all-point method, and the quadratic regression model showed the best fit for both AFP and hCG in the median regression method, with adjusted R(2)s of 0.987 and 0.988, respectively. Conclusion: The quadratic regression model was found to be the most suitable for Chinese pregnant women. (c) 2006 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:21 / 25
页数:5
相关论文
共 50 条
  • [1] Weight-correction formula for maternal serum screening for Down syndrome in Taiwan
    Jou, HJ
    Wu, SC
    Lu, YM
    Liao, WC
    Hsieh, FJ
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2000, 99 (12) : 931 - 935
  • [2] MATERNAL SERUM MARKERS AND PRENATAL SCREENING FOR DOWN-SYNDROME
    LEYMARIE, P
    LEPORRIER, N
    ARCHIVES FRANCAISES DE PEDIATRIE, 1993, 50 (05): : 455 - 457
  • [3] Prenatal screening for Down's syndrome using maternal serum markers
    Dhondt, JL
    ANNALES DE BIOLOGIE CLINIQUE, 1998, 56 (04) : 471 - 475
  • [4] MATERNAL SERUM MARKERS IN SCREENING FOR DOWN SYNDROME
    NORGAARDPEDERSEN, B
    LARSEN, SO
    ARENDS, J
    SVENSTRUP, B
    TABOR, A
    CLINICAL GENETICS, 1990, 37 (01) : 35 - 43
  • [5] Weight adjustment of serum markers in early first-trimester prenatal screening for Down syndrome
    Sorensen, T
    Larsen, SO
    Christiansen, M
    PRENATAL DIAGNOSIS, 2005, 25 (06) : 484 - 488
  • [6] Prenatal screening for Down's syndrome with maternal markers: Tunisian experience
    Ferchichi, S.
    Chahed, H.
    Jaidane, Z.
    Chaabouni, Y.
    Saafi, N.
    Limem, H. B.
    Sakouhi, M.
    Bernard, M.
    Khairi, H.
    Laradi, S.
    Miled, A.
    IMMUNO-ANALYSE & BIOLOGIE SPECIALISEE, 2010, 25 (04): : 205 - 211
  • [7] The impact of maternal weight discrepancies on prenatal screening results for Down syndrome
    Huang, Tianhua
    Meschino, Wendy S.
    Okun, Nan
    Dennis, Alan
    Hoffman, Barry
    Lepage, Nathalie
    Rashid, Shamim
    Aul, Ritu
    Farrell, Sandra A.
    PRENATAL DIAGNOSIS, 2013, 33 (05) : 471 - 476
  • [8] Performance of prenatal screening using maternal serum and ultrasound markers for Down syndrome in Chinese women: a systematic review and meta-analysis
    Tu, S.
    Rosenthal, M.
    Wang, D.
    Huang, J.
    Chen, Y.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2016, 123 : 12 - 22
  • [9] PRENATAL SCREENING FOR DOWNS-SYNDROME WITH USE OF MATERNAL SERUM MARKERS
    HADDOW, JE
    PALOMAKI, GE
    KNIGHT, GJ
    WILLIAMS, J
    PULKKINEN, A
    CANICK, JA
    SALLER, DN
    BOWERS, GB
    NEW ENGLAND JOURNAL OF MEDICINE, 1992, 327 (09): : 588 - 593
  • [10] Economic analysis of maternal serum markers screening for Down syndrome.
    Seror, V
    Costet, N
    Le Gales, C
    Ayme, S
    AMERICAN JOURNAL OF HUMAN GENETICS, 1997, 61 (04) : A57 - A57