Comparison of 51Cr-EDTA and 99mTc-DTPA for glomerular filtration rate measurement

被引:18
|
作者
Vidal-Petiot, Emmanuelle [1 ,2 ,3 ]
Courbebaisse, Marie [1 ,4 ,5 ]
Livrozet, Marine [6 ,7 ]
Correge, Gwenaelle [8 ]
Rusu, Timofei [8 ]
Montravers, Francoise [6 ,8 ]
Baron, Stephanie [1 ,4 ,9 ]
Dupont, Lea [10 ]
Balouzet, Clara [10 ]
Smadja, Corinne [10 ]
Leygnac, Sebastien [11 ,12 ]
Pariscoat, Guillaume [11 ,13 ]
Rose, Jimmy [13 ]
Rouzet, Francois [1 ,11 ,14 ]
Houillier, Pascal [1 ,4 ,9 ]
Haymann, Jean-Philippe [6 ,7 ]
Flamant, Martin [1 ,2 ,3 ]
机构
[1] Univ Paris, Paris, France
[2] Hop Bichat Claude Bernard, AP HP, Physiol Dept, 46 Rue Henri Huchard, F-75018 Paris, France
[3] Ctr Res Inflammat, INSERM, U1149, Paris, France
[4] Hop Europeen Georges Pompidou, AP HP, Physiol Dept, F-75015 Paris, France
[5] CNRS, Inst Necker Enfants Malad, INSERM, U1151,UMR8253, Paris, France
[6] Sorbonne Univ, Paris, France
[7] Hop Tenon, AP HP, Physiol Dept, F-75020 Paris, France
[8] Hop Tenon, AP HP, Dept Nucl Med, F-75020 Paris, France
[9] Univ Paris, Ctr Rech Cordeliers, INSERM, F-75006 Paris, France
[10] Hop Europeen Georges Pompidou, AP HP, Radiopharm Unit, F-75015 Paris, France
[11] Hop Bichat Claude Bernard, AP HP, Dept Nucl Med, F-75018 Paris, France
[12] Hop Bichat Claude Bernard, AP HP, Dept Radiol, F-75018 Paris, France
[13] Hop Bichat Claude Bernard, AP HP, Radiopharm Unit, F-75018 Paris, France
[14] INSERM, U1148, Lab Vasc Translat Res, F-75018 Paris, France
关键词
Glomerular filtration rate measurement; (51)cr-EDTA; (99m)tc-DTPA; Radio-labelled tracers; Plasma clearance; Renal clearance;
D O I
10.1007/s40620-020-00932-9
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose The production of Cr-51-labelled ethylenediaminetetraacetic acid (Cr-51-EDTA), a validated and widely used radio-isotopic tracer for glomerular filtration rate (GFR) measurement in Europe, was recently halted by the manufacturer. Technetium-99m-diethylenetriaminepentaacetic acid (Tc-99m-DTPA) clearance has so far mostly been restricted to assessment of separate renal function by scintigraphy, but scarcely used and validated for GFR measurement. We compared the performances of Cr-51-EDTA and Tc-99m-DTPA for GFR and extracellular fluid measurement. Methods In a multi-centre prospective study, Cr-51-EDTA and Tc-99m-DTPA were simultaneously injected into 88 patients, and their urinary and plasma clearances, as well as their volumes of distribution, were measured during seven 30-min periods after a 90-min equilibrium time. Results Mean age was 52.2 +/- 14.5 years, 59% were men. Urinary clearances of Cr-51-EDTA and Tc-99m-DTPA were 64.1 +/- 27.6 and 66.1 +/- 28.0 mL/min, respectively, with a mean bias of 2.00 +/- 2.25 mL/min, an accuracy within 10% of 95% [95% CI 91-99], and a coefficient of determination (R-2) of 0.994. Plasma clearances of Cr-51-EDTA and Tc-99m-DTPA were 66.1 +/- 25.8 and 68.1 +/- 26.6 mL/min, respectively, with a mean bias of 1.96 +/- 3.32 mL/min, an accuracy within 10% of 91% [95% CI 85-97] and a R-2 of 0.985. Distribution volumes were 17.3 +/- 4.6 L for Cr-51-EDTA and 16.6 +/- 4.6 L for Tc-99m-DTPA (R-2 0.930). Conclusion The accuracy and precision of Tc-99m-DTPA clearance, compared to Cr-51-EDTA clearance, was excellent for both urinary and plasma clearance methods, despite an approximate 2 mL/min overestimation, showing that the tracer is a reliable alternative to Cr-51-EDTA for GFR measurement. [GRAPHICS] .
引用
收藏
页码:729 / 737
页数:9
相关论文
共 50 条
  • [1] Comparison of 51Cr-EDTA and 99mTc-DTPA for glomerular filtration rate measurement
    Emmanuelle Vidal-Petiot
    Marie Courbebaisse
    Marine Livrozet
    Gwénaëlle Corrégé
    Timofei Rusu
    Françoise Montravers
    Stéphanie Baron
    Léa Dupont
    Clara Balouzet
    Corinne Smadja
    Sébastien Leygnac
    Guillaume Pariscoat
    Jimmy Rose
    François Rouzet
    Pascal Houillier
    Jean-Philippe Haymann
    Martin Flamant
    Journal of Nephrology, 2021, 34 : 729 - 737
  • [2] Comparison of 99mTc-DTPA and 51Cr-EDTA for glomerular filtration rate measurement with the continuous infusion method
    Balouzet, Clara
    Michon-Colin, Arthur
    Dupont, Lea
    Vidal-Petiot, Emmanuelle
    Prot-Bertoye, Caroline
    Baron, Stephanie
    Ayari, Hamza
    Cohen, Raphal
    Houillier, Pascal
    Smadja, Corinne
    Flamant, Martin
    Courbebaisse, Marie
    JOURNAL OF NEPHROLOGY, 2023, 36 (09) : 2457 - 2465
  • [3] Comparison of 99mTc-DTPA and 51Cr-EDTA for glomerular filtration rate measurement with the continuous infusion method
    Clara Balouzet
    Arthur Michon-Colin
    Léa Dupont
    Emmanuelle Vidal-Petiot
    Caroline Prot-Bertoye
    Stéphanie Baron
    Hamza Ayari
    Raphaël Cohen
    Pascal Houillier
    Corinne Smadja
    Martin Flamant
    Marie Courbebaisse
    Journal of Nephrology, 2023, 36 : 2457 - 2465
  • [4] Comparison of 99mTc-DTPA and 51Cr-EDTA for glomerular filtration rate measurement with a bolus followed by a continuous infusion
    Balouzet, Clara
    Dupont, Lea
    Ayari, Hamza
    Cohen, Raphael
    Schurder, Juliet
    Baron, Stephanie
    Houillier, Pascal
    Vidal-Petiot, Emmanuelle
    Smadja, Corinne
    Courbebaisse, Marie
    ACTA PHYSIOLOGICA, 2019, 227
  • [5] Glomerular filtration rate: comparison of simultaneous plasma clearance of 99mTc-DTPA and 51Cr-EDTA revisited
    Simonsen, Jane A.
    Thilsing-Hansen, Kasper
    Hoilund-Carlsen, Poul F.
    Gerke, Oke
    Andersen, Thomas L.
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2020, 80 (05): : 408 - 411
  • [6] Comparison of glomerular filtration rate estimation by 99mTc-DTPA to the reference radiotracer 51Cr-EDTA compared to methods based on blood creatinine measurement
    Saleh, N. S.
    Marie, S.
    Grimon, G.
    Durand, E.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2021, 45 (03): : 142 - 146
  • [7] Comparison of 51Cr-EDTA with 99mTc-DTPA slope clearance for estimation of glomerular filtration rate using the one-compartment model
    Chapot, C
    Seifert, H
    Samnick, S
    Kirsch, CM
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 1998, 37 (04): : 124 - 128
  • [8] Replacing 51Cr-EDTA with 99mTc-DTPA in GFR measurement : a prospective comparative study
    Arsos, G.
    Moralidis, E.
    Kalaitzogloy, A.
    Katsampoukas, D.
    Sachpekidis, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S510 - S511
  • [9] THE EVALUATION OF 99MTC-DTPA RENOGRAPHY ON THE MEASUREMENT OF GLOMERULAR FILTRATION RATE
    Ma, Yingchun
    Zuo, Li
    Wang, Mei
    Wang, Haiyan
    NEPHROLOGY, 2005, 10 : A144 - A144
  • [10] Determination of the glomerular filtration rate in patients with type 2 diabetes: An assessment of the agreement between 51Cr-EDTA plasma clearance and 99mTc-DTPA plasma clearance, 99mTc-DTPA renography and plasma creatinine prediction equation
    Moralidis, Efstratios
    Papanastasiou, Emmanouil
    Didangelos, Triantafyllos
    Hilidis, Ilias
    Siountas, Anastasios
    Arsos, Georgios
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2020, 161