Radon concentration measurements and personnel exposure levels in Bavarian water supply facilities

被引:11
|
作者
Trautmannsheimer, M [1 ]
Schindlmeier, W [1 ]
Börner, K [1 ]
机构
[1] Bavarian Environm Protect Agcy, D-86177 Augsburg, Germany
来源
HEALTH PHYSICS | 2003年 / 84卷 / 01期
关键词
radon; water; ground; detectors; etched-track; exposure; occupational;
D O I
10.1097/00004032-200301000-00009
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
As part of a study covering the whole of Bavaria, the southern most of Germany's 16 states, water supply facilities were examined to determine the radon (Rn-222) concentrations in ground water and indoor air and the radon exposure to the staff working in these buildings. Bavaria can be divided into ten geological regions of different geogenic radon potential. From each region, a number of water supply facilities proportional to the size of the region were selected for measurements. Over 500 of a total number of 2,600 water supply facilities were asked to take a 1-L groundwater sample and expose several track-etch detectors in order to obtain the mean room concentration of the main staff work places. In addition, for a period of 2 mo, the personnel had to wear a track-etch detector during the time they spent in the supply facilities. The resulting measurements were then used to estimate their individual effective dose of radon and its progenies. In the East Bavarian crystalline region, the region of the highest geogenic radon potential within Bavaria, indoor radon gas concentrations of up to 400 kBq m(-3) were observed. About 10% of the process controllers in this region are subjected to an annual effective dose of more than 20 mSv. In the other Bavarian regions, only 2% of staff exposure levels exceed this limit. The correlation between the radon concentration measurements of the indoor air, the ground water, and individual personnel exposure levels was determined. The average ratio of the radon indoor air to the processed groundwater concentration is 0.14. But due to the different types of ventilation in the various supply facilities, there can be great variations in this figure. Therefore, there is no clear relationship between the groundwater and the indoor air concentration of a supply facility. This study also reveals no clear relationship between radon indoor air concentrations and the personnel exposure levels of a supply facility.
引用
收藏
页码:100 / 110
页数:11
相关论文
共 39 条
  • [1] Investigation and reduction of personnel exposure levels in Bavarian water supply facilities
    Körner, S
    Trautmannsheimer, M
    Hübel, K
    HIGH LEVELS OF NATURAL RADIATION AND RADON AREAS: RADIATION DOSE AND HEALTH EFFECTS, 2005, 1276 : 240 - 241
  • [2] Radon turnover in water supply facilities
    Hingmann, H
    Allinger, T
    Korte, T
    Kubetzek, L
    Peeck, DA
    Weber, U
    RADIOACTIVITY IN HUMANS AND THE ENVIRONMENT, 1998, : 544 - 549
  • [3] Tailing facilities and water supply at concentration plant
    Kononchuk, V.P.
    Gornyi Zhurnal, 2001, (06): : 60 - 61
  • [4] Evaluation of radon concentration measurements in water using the radon degassing method
    Matsumoto, Maho
    Yasuoka, Yumi
    Takakaze, Yui
    Hosoda, Masahiro
    Tokonami, Shinji
    Iwaoka, Kazuki
    Mukai, Takahiro
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2023, 332 (01) : 167 - 172
  • [5] Evaluation of radon concentration measurements in water using the radon degassing method
    Maho Matsumoto
    Yumi Yasuoka
    Yui Takakaze
    Masahiro Hosoda
    Shinji Tokonami
    Kazuki Iwaoka
    Takahiro Mukai
    Journal of Radioanalytical and Nuclear Chemistry, 2023, 332 : 167 - 172
  • [6] Radon exposure at drinking water supply plants in Slovenia
    Vaupotic, J
    HEALTH PHYSICS, 2002, 83 (06): : 901 - 906
  • [7] Radon-222 concentration in water and the exposure of the public
    Ren, T
    Shang, B
    Yu, Y
    Guo, H
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 2, 1996, : B113 - B115
  • [8] MEASUREMENTS OF INDOOR RADON CONCENTRATION LEVELS IN DWELLINGS IN BETHLEHEM, PALESTINE
    Leghrouz, Amin A.
    Abu-Samreh, Mohammad M.
    Shehadeh, Ayah K.
    HEALTH PHYSICS, 2013, 104 (02): : 163 - 167
  • [9] COMPLEMENTARY MEASUREMENTS OF RADON CONCENTRATION IN WATER SOURCES AND NATURAL EXPOSURE IN DWELLINGS IN THE VICINITY OF THE RAMSAR HLNRA, IRAN
    Amirzadi, Mehrdad
    Pooya, Seyed Mandi Hosseini
    Taheri, Mehran
    Babakhani, Asad
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2012, 27 (04): : 399 - 403
  • [10] Radon-222 Exposure and Dose Concentration Levels in Jordanian Dwellings
    Al-Kazwini, Akeel T.
    Al-Arnaout, Mohannad M.
    Abdulkareem, Tiba R.
    JOURNAL OF ENVIRONMENTAL AND PUBLIC HEALTH, 2020, 2020