Performance Analysis of a Overhead Power Transmission Line Tower Using Polymer Composite Material

被引:18
|
作者
Selvaraj, M. [1 ]
Kulkarni, S. M. [2 ]
Rameshbabu, R. [1 ]
机构
[1] Cent Power Res Inst, Sir CV Raman Rd, Bangalore 560080, Karnataka, India
[2] Natl Inst Technol Karnataka, Mangalore 575025, India
关键词
Composite materials; Materials testing; Transmission lines; Towers;
D O I
10.1016/j.mspro.2014.07.451
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
For technical, aesthetic and economic reasons, our next generation overhead power transmission lines will be built with new materials and new design concepts in order to reduce the dimensions of the support structures. This paper discusses the mechanical performance tests carried out on a 66 kV overhead power transmission line tower built with Fiber Reinforced Polymer (FRP) composite material for the first time in India. The details of development of composite tower and its performance during full scale test carried out at Central Power Research Institute (CPRI) Bangalore, India are presented (C) 2014 Elsevier Ltd.
引用
收藏
页码:1340 / 1348
页数:9
相关论文
共 50 条
  • [1] Transient Lightning Impulse Performance Analysis for Composite Transmission Line Tower
    Huangfu, Youpeng
    Wang, Shuhong
    Tao, Xi
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2015, 57 (05) : 1103 - 1111
  • [2] Assessing the power transfer performance of a lattice tower overhead line system
    Kopsidas, Konstantinos
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2013, 7 (01) : 90 - 100
  • [3] Modeling and Insulation Performance Analysis of Composite Transmission Line Tower Under Lightning Overvoltage
    Huangfu, Youpeng
    Wang, Shuhong
    Wang, Guolin
    Xu, Weijie
    Zhang, Haijun
    IEEE TRANSACTIONS ON MAGNETICS, 2015, 51 (03)
  • [4] First tower line using composite material commissioned in Jiangsu
    Liu Chunsheng
    Electricity, 2010, 21 (01) : 7 - 7
  • [5] Composite Grounding Application of Transmission Line Tower with Flexible Graphite Grounding Material
    Liu, Hongtao
    Zhang, Lei
    Xiong, Jia
    Cui, Zhenxing
    Yang, Qi
    2ND INTERNATIONAL CONFERENCE ON DESIGN, MATERIALS, AND MANUFACTURING, 2017, 220
  • [6] Experimental Study on Strengthening the Structure of Tower of Overhead Transmission Line
    Liu, Xuewu
    Xia, Kaiquan
    Gao, Yan
    VIBRATION, STRUCTURAL ENGINEERING AND MEASUREMENT I, PTS 1-3, 2012, 105-107 : 1069 - 1072
  • [7] Stability Analysis of Electric Transmission Line Tower Made with Composite Material Carbon Fiber Epoxy - An Innovative Approach
    Bhowmik, Chiranjit
    Chakraborti, Prasun
    REVUE DES COMPOSITES ET DES MATERIAUX AVANCES-JOURNAL OF COMPOSITE AND ADVANCED MATERIALS, 2019, 29 (01): : 9 - 13
  • [8] Lightning Performance Analysis of an Overhead Transmission Line Protected by Surge Arresters
    Velasco, J. A. M.
    Aranda, F. C.
    IEEE LATIN AMERICA TRANSACTIONS, 2009, 7 (01) : 62 - 70
  • [9] Lightning Performance of Overhead Hybrid Transmission Line
    Mackow, Andrzej
    Kizilcay, Mustafa
    Malicki, Pawel
    2015 IEEE EINDHOVEN POWERTECH, 2015,
  • [10] Analysis and experimental testing of a built-up composite cross arm in a transmission line tower for mechanical performance
    Selvaraj, Munusamy
    Kulkarni, Satyabodh
    Babu, Ramamurthy Ramesh
    COMPOSITE STRUCTURES, 2013, 96 : 1 - 7