(PMP); Diffusion charger (DC); Particle number counter (PNC); Condensation particle counter (CPC); Volatile particle remover (VPR); Portable emissions measurement system (PEMS); PARTICULATE-EMISSIONS; EXHAUST PARTICLES; DIESEL-ENGINES; PASSENGER CAR; DUTY VEHICLES; CALIBRATION; LUBRICANT; FRAMEWORK; IMPACT; FUEL;
D O I
10.1016/j.envres.2021.111068
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the European Union's emissions regulations, limits for solid particles >23 nm are applicable for the typeapproval and in use compliance of vehicles. Consequently, particle number (PN) systems are used very often for both research and development of engines and vehicles, both in the laboratory and on the road. The technical specifications of the laboratory and portable on-board systems are not the same resulting in different measurement uncertainties. Furthermore, particles, in contrast to gases, can be lost in the transfer lines making comparisons at different sampling locations difficult. Moreover, the size dependent counting efficiency of the systems can result in high discrepancies when the measured particle sizes are close to the decreasing steep part of the curves. The different sampling locations (tailpipe or dilution tunnel) and thermal pretreatments of the aerosol further enhance the differences. The studies on the measurement uncertainty are scarce, especially for the PN systems measuring from 10 nm that will be introduced in the future regulations. This study quantified the uncertainty sources of the PN systems: (i) due to the technical requirements and the calibrations, (ii) due to the unknown particle sizes during measurement, (iii) due to particle losses from the vehicle to the PN systems at the tailpipe or the dilution tunnel, (iv) other parameters needed for the calculation of the emissions, non-related to the PN systems, e.g. flow and distance. The expanded uncertainty of the 23 nm laboratory systems sampling from the dilution tunnel was estimated to be 32%, with 18% originating from the calibration procedures, while of those sampling from the tailpipe 34%. For the 23 nm portable systems measuring on-road the uncertainty was 39%. The values were 2-8% higher for the 10 nm systems.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Solid Particle Number (SPN) Portable Emissions Measurement Systems (PEMS) in the European Legislation: A Review
    Giechaskiel, Barouch
    Bonnel, Pierre
    Perujo, Adolfo
    Dilara, Panagiota
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (23)
  • [2] Investigation of Equivalency between Laboratory-Grade and Portable Emissions Measurement Systems in Solid Particle Number Measurement Larger than 10 nm
    Otsuki Y.
    Fukushima S.
    Nakamura H.
    Kojima K.
    Sakurai H.
    SAE International Journal of Advances and Current Practices in Mobility, 2023, 6 (01):
  • [3] Experimental assessment of solid particle number Portable Emissions Measurement Systems (PEMS) for heavy-duty vehicles applications
    Giechaskiel, Barouch
    Schwelberger, Matthias
    Delacroix, Christophe
    Marchetti, Massimo
    Feijen, Marc
    Prieger, Klaus
    Andersson, Sven
    Karlsson, Hua Lu
    JOURNAL OF AEROSOL SCIENCE, 2018, 123 : 161 - 170
  • [4] Measurements of the Emissions of a "Golden" Vehicle at Seven Laboratories with Portable Emission Measurement Systems (PEMS)
    Giechaskiel, Barouch
    Casadei, Simone
    Rossi, Tommaso
    Forloni, Fabrizio
    Di Domenico, Andrea
    SUSTAINABILITY, 2021, 13 (16)
  • [5] Framework for the assessment of PEMS (Portable Emissions Measurement Systems) uncertainty
    Giechaskiel, Barouch
    Clairotte, Michael
    Valverde-Morales, Victor
    Bonnel, Pierre
    Kregar, Zlatko
    Franco, Vicente
    Dilara, Panagiota
    ENVIRONMENTAL RESEARCH, 2018, 166 : 251 - 260
  • [6] Development of a particle number and particle mass vehicle emissions inventory for an urban fleet
    Keogh, Diane U.
    Ferreira, Luis
    Morawska, Lidia
    ENVIRONMENTAL MODELLING & SOFTWARE, 2009, 24 (11) : 1323 - 1331
  • [7] Laboratory measurements with solid particle number instruments designed for periodic technical inspection (PTI) of vehicles
    Melas, Anastasios
    Vasilatou, Konstantina
    Suarez-Bertoa, Ricardo
    Giechaskiel, Barouch
    MEASUREMENT, 2023, 215
  • [8] Vehicle Emission Factors of Solid Nanoparticles in the Laboratory and on the Road Using Portable Emission Measurement Systems (PEMS)
    Giechaskiel, Barouch
    Riccobono, Francesco
    Vlachos, Theodoros
    Mendoza-Villafuerte, Pablo
    Suarez-Bertoa, Ricardo
    Fontaras, Georgios
    Bonnel, Pierre
    Weiss, Martin
    FRONTIERS IN ENVIRONMENTAL SCIENCE, 2015, 3
  • [9] Assessment of 10-nm Particle Number (PN) Portable Emissions Measurement Systems (PEMS) for Future Regulations
    Giechaskiel, Barouch
    Lahde, Tero
    Gandi, Sawan
    Keller, Stefan
    Kreutziger, Philipp
    Mamakos, Athanasios
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (11)
  • [10] On-road vehicle measurements of brake wear particle emissions
    zum Hagen, Ferdinand H. Farwick
    Mathissen, Marcel
    Grabiec, Tomasz
    Hennicke, Tim
    Rettig, Marc
    Grochowicz, Jaroslaw
    Vogt, Rainer
    Benter, Thorsten
    ATMOSPHERIC ENVIRONMENT, 2019, 217