Cavitation Influence on the Operation of a Pumping Station Rig with Variable Speed Pumps

被引:0
|
作者
Ciuc, Petre-Ovidiu [1 ]
Madularea, Remus Alexandra [1 ]
Georgescu, Andrei-Mugur [2 ]
Georgescu, Sanda-Carmen [3 ]
Dunca, Georgiana [3 ]
Bucur, Diana Maria [3 ]
机构
[1] Univ Politehn Bucuresti, Power Engn Doctoral Sch, Bucharest, Romania
[2] Tech Univ Civil Engn Bucharest, Dept Hydraul & Environm Protect, Bucharest, Romania
[3] Univ Politehn Bucuresti, Dept Hydraul Hydraul Machinery & Environm Engn, Bucharest, Romania
关键词
cavitation; NPSH; pumping station; variable speed pump;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To analyse duty points dropdown when centrifugal pumps run with cavitation on their suction side, experiments were conducted on a pumping station (PS) rig, where up to three variable speed driven pumps can run in parallel-coupling. The PS rig is equipped with insufficient measuring devices, like most urban PS-s. The duty points shifting was assessed with respect to pumps' performance curves. A comparison was made with respect to duty points obtained for a regime free of cavitation, after changing the suction pipe (from DN40 to DN63). Global recordings were available, namely a pressure head inside the PS-unit, and the total discharge flow rate at the PS exit. Duty points for each pump were derived using a sensorless control approach and the affinity laws. For the pumps running at nominal speed, the fully cavitating and the incipient cavitating regimes were proved by the NPSH available at the pump inlet, with respect to the NPSH required by the pump. The fully developed cavitation starts way below the 3% head dropdown limit.
引用
收藏
页码:239 / 243
页数:5
相关论文
共 50 条
  • [1] Analysis of Variable Speed Optimization Operation Effect of Different-type Pumps in Jiangdu Pumping Station
    Qiu Jinxian
    Cheng Jilin
    Luo Jinyao
    Zhang Rentian
    Zhang Lihua
    Gong Yi
    [J]. 10TH ASIAN INTERNATIONAL CONFERENCE ON FLUID MACHINERY, 2010, 1225 : 447 - +
  • [2] Optimal Scheduling of Variable Speed Pumps in Mahasawat Water Distribution Pumping Station
    Soonthornnapha, Tomorn
    [J]. 2017 INTERNATIONAL ELECTRICAL ENGINEERING CONGRESS (IEECON), 2017,
  • [3] Optimal operation scheduling of a pumping station with multiple pumps
    Zhuan, Xiangtao
    Xia, Xiaohua
    [J]. APPLIED ENERGY, 2013, 104 : 250 - 257
  • [4] INFLUENCE OF VOLTAGE ON PUMPING SPEED OF ION PUMPS
    DESIMON, M
    [J]. VIDE-SCIENCE TECHNIQUE ET APPLICATIONS, 1990, 45 (254): : 373 - 378
  • [5] Optimal Regulation of Pumping Station in Water Distribution Networks Using Constant and Variable Speed Pumps: A Technical and Economical Comparison
    Cimorelli, Luigi
    Covelli, Carmine
    Molino, Bruno
    Pianese, Domenico
    [J]. ENERGIES, 2020, 13 (10)
  • [6] Variable Rotational Speed Control System of Sewage Pumping Station
    Szychta, E.
    Szychta, L.
    [J]. TRANSNAV-INTERNATIONAL JOURNAL ON MARINE NAVIGATION AND SAFETY OF SEA TRANSPORTATION, 2019, 13 (02) : 343 - 346
  • [7] Combinatorial Optimization Method for Operation of Pumping Station with Adjustable Blade and Variable Speed Based on Experimental Optimization of Subsystem
    Gong, Yi
    Cheng, Jilin
    [J]. ADVANCES IN MECHANICAL ENGINEERING, 2014,
  • [8] PUMPS AND DIESELS IN BAGLAN PUMPING STATION
    KELSEY, AJ
    [J]. WATER SERVICES, 1978, 82 (990): : 499 - &
  • [9] Basis of the Variable Speed Driving Pumps Parallel Operation Modeling
    Grigoriu, Mircea
    [J]. MACMESE 2008: PROCEEDINGS OF THE 10TH WSEAS INTERNATIONAL CONFERENCE ON MATHEMATICAL AND COMPUTATIONAL METHODS IN SCIENCE AND ENGINEERING, PTS I AND II, 2008, : 200 - +
  • [10] Variable-speed pumps create benefits for Austrian power station
    Minett, S
    [J]. TURBOMACHINERY INTERNATIONAL, 2001, 42 (01) : 32 - 34