Prognostic value of baseline electrophysiology studies in patients with sustained ventricular tachyarrhythmia: The Antiarrhythmics Versus Implantable Defibrillators (AVID) trial

被引:26
|
作者
Brodsky, MA
Mitchell, LB
Halperin, BD
Raitt, MH
Hallstorm, AP
机构
[1] Univ Calif Irvine, Med Ctr, Div Cardiol, Orange, CA 92868 USA
[2] Univ Calgary, Div Cardiol, Calgary, AB, Canada
[3] Oregon Hlth & Sci Univ, Div Cardiol, Portland, OR 97201 USA
[4] Portland Vet Adm Hosp, Portland, OR 97201 USA
[5] Univ Washington, Seattle, WA 98195 USA
关键词
D O I
10.1067/mhj.2002.125502
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives We sought to determine the value of electrophysiology (EP) testing in patients with ventricular fibrillation (VF), ventricular tachycardia (VT) with syncope, or sustained VT in the setting of left ventricular dysfunction. Background Traditionally, EP testing is part of the workup of patients with sustained VT or VF. Recently, some have suggested that EP testing is unnecessary in these patients, many of whom are likely to receive an implantable cardioverter-defibrillator (ICD). Methods Within a multicenter trial (Antiarrhythmics Versus Implantable Defibrillators) designed to evaluate whether drugs or ICD resulted in a better outcome, data were analyzed regarding EP testing. Although this testing was not required, it was performed in >50% of patients. Information regarding the results of EP testing was correlated to baseline clinical characteristics and outcome. Results Of 572 patients subjected to an EP test, 384 (67%) had inducible sustained VT or VF. Inducible patients were more likely to have coronary artery disease, previous infarction, and VT as their index arrhythmic event. Inducibility of VT or VF did not predict death or recurrent VT or VF. Conclusions Information derived from EP testing in this patient population, particularly those with VF, is of limited value and may not be worth the risks and costs of the procedure, particularly in those patients likely to receive an ICD.
引用
收藏
页码:478 / 484
页数:7
相关论文
共 50 条
  • [1] Prognostic value of baseline electrophysiology studies - The Antiarrhythmics Versus Implantable Defibrillators (AVID) Trial
    Halperin, BD
    Brodsky, MA
    Lancaster, S
    Raitt, M
    Kron, J
    Akiyama, T
    Englestein, ED
    Jodanath, R
    Mitchell, LB
    Daubert, JP
    [J]. CIRCULATION, 1997, 96 (08) : 1865 - 1865
  • [2] Baseline prognostic indicators in patients with sustained ventricular tachyarrhythmias: The antiarrhythmics versus implantable defibrillator (AVID) trial registry
    Pinski, SL
    Yao, Q
    Cook, JR
    Epstein, AE
    Marinchak, RA
    Pacifico, A
    Wilkoff, BL
    Bigger, TJ
    Lancaster, S
    Englestein, ED
    Jadonath, R
    [J]. CIRCULATION, 1997, 96 (08) : 1867 - 1867
  • [3] Determinants of outcome in patients with sustained ventricular tachyarrhythmias: The Antiarrhythmics Versus Implantable Defibrillators (AVID) Study Registry
    Pinski, SL
    Yao, Q
    Epstein, AE
    Lancaster, S
    Greene, HL
    Pacifico, A
    Cook, JR
    Jadonath, R
    Marinchak, RA
    [J]. AMERICAN HEART JOURNAL, 2000, 139 (05) : 804 - 813
  • [4] Causes of death in the Antiarrhythmics Versus Implantable Defibrillators (AVID) Trial
    Richardson, DW
    Cobb, LA
    Pratt, CM
    Anderson, JL
    Ehlert, F
    Epstein, AE
    Flynn, D
    Greene, HL
    Hallstrom, AP
    Kim, S
    Klevan, LR
    Moore, R
    Mounsey, P
    Pratt, CM
    Richardson, DW
    Schron, E
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (05) : 1552 - 1559
  • [5] Causes of death in the antiarrhythmics versus implantable defibrillators (AVID) trial
    Pratt, CM
    Greene, L
    Anderson, JL
    Cobb, LA
    Epstein, AE
    Flynn, D
    Kim, S
    Richards, DW
    Schron, E
    Epstein, AE
    [J]. CIRCULATION, 1998, 98 (17) : 494 - 495
  • [6] Quality of life in patients enrolled in the antiarrhythmics versus implantable defibrillators(AVID)Trial
    Jenkins, LS
    Steinberg, JS
    Kutalek, SP
    Cook, JR
    Schron, EB
    Friedman, PL
    Cross, J
    BosworthFarrel, S
    Roth, J
    Yao, Q
    [J]. CIRCULATION, 1997, 96 (08) : 2451 - 2451
  • [7] Comparison of arrhythmia recurrence in patients presenting with ventricular fibrillation versus ventricular tachycardia in the antiarrhythmics versus implantable defibrillators (AVID) trial
    Raitt, MH
    Klein, RC
    Wyse, DG
    Wilkoff, BL
    Beckman, K
    Epstein, AE
    Coromilas, J
    Friedman, PL
    Martins, J
    Ledingham, RB
    Greene, HL
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2003, 91 (07): : 812 - 816
  • [8] Arrhythmia recurrence in patients presenting with ventricular fibrillation compared to ventricular tachycardia in the antiarrhythmics versus implantable defibrillators (AVID) trial
    Raitt, MH
    Klein, RC
    Greene, LH
    Wilkoff, BL
    Wyse, GD
    Beckman, KJ
    Martins, JB
    Kim, SG
    Epstein, AE
    Engelstein, ED
    Friedman, PI
    [J]. CIRCULATION, 1998, 98 (17) : 494 - 494
  • [9] Spousal quality of life in the antiarrhythmics versus implantable defibrillators (AVID) trial
    Bosworth-Farrell, SA
    Schron, E
    Yao, Q
    Powell, J
    Collura, R
    Jenkins, L
    Kandrac, J
    Nelson, L
    [J]. CIRCULATION, 1999, 100 (18) : 254 - 254
  • [10] Analysis of implantable cardioverter defibrillator therapy in the antiarrhythmics versus implantable defibrillators (AVID) trial
    Klein, RC
    Raitt, MH
    Greene, HL
    Beekman, K
    Coromilas, J
    Wilkoff, BL
    Wyse, DG
    Friedman, PL
    Martins, JB
    Epstein, AE
    Engelstein, ED
    [J]. CIRCULATION, 1998, 98 (17) : 191 - 191