Accident Scenarios Caused by Lightning Impact on Atmospheric Storage Tanks

被引:4
|
作者
Necci, Amos [1 ]
Antonioni, Giacomo [1 ]
Krausmann, Elisabeth [2 ]
Argenti, Francesca [3 ]
Landucci, Gabriele [3 ]
Cozzani, Valerio [1 ]
机构
[1] Alma Mater Studiorum Univ Bologna, DICAM Dipartimento Ingn Civile Chim Ambientale &, Via Terracini 28, I-40131 Bologna, Italy
[2] Inst Protect & Secur Citizen, Joint Res Ctr, European Commiss, Ispra, Italy
[3] Univ Pisa, Dipartimento Ingn & Civile Ind, I-56126 Pisa, Italy
关键词
QUANTITATIVE RISK-ASSESSMENT; METHODOLOGY; MITIGATION; EVENTS; DAMAGE;
D O I
10.3303/CET1332024
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In recent years, severe natural events raised the concern for the so-called NaTech (natural-technological) accident scenarios: technological accidents caused by the impact of a natural event on an industrial facility or infrastructure. Severe scenarios typical of the process industry, as fires, explosions, toxic releases, and water pollution were reported as the consequence of natural events in industrial areas. The historical analysis of accidental scenarios triggered by lightning shows that the impact of a lightning on an atmospheric storage tank might be the initiating event of a severe accident. The analysis of past accident evidences that several alternative damage mechanisms and accident scenarios may follow lightning impact. Although lightning hazard is well known and is usually considered in the risk analysis of chemical and process plants, well accepted quantitative procedures to assess the contribution of accidents triggered by lightning to industrial risk are still lacking. In particular, the approaches to the assessment of accident scenarios following lightning strike are mostly based on expert judgment. In the present study, a detailed methodology is presented for the assessment of quantified event trees following lightning impact on an atmospheric tank. Different damage mechanisms have been considered in order to assess the frequencies of loss of containment due to lightning strikes. The results were used in a case study to assess the overall risk due to lightning impact scenarios in typical lay-outs of tank farms of oil refineries.
引用
收藏
页码:139 / 144
页数:6
相关论文
共 50 条
  • [1] Accident scenarios triggered by lightning strike on atmospheric storage tanks
    Necci, Amos
    Argenti, Francesca
    Landucci, Gabriele
    Cozzani, Valerio
    [J]. RELIABILITY ENGINEERING & SYSTEM SAFETY, 2014, 127 : 30 - 46
  • [2] Integration of Fire Safety Barriers in the Probabilistic Analysis of Accident Scenarios Triggered by Lightning Strike on Atmospheric Storage Tanks
    Bilal Benkaouha
    Zakarya Chiremsel
    Djamel Bellala
    [J]. Journal of Failure Analysis and Prevention, 2022, 22 : 2326 - 2351
  • [3] Integration of Fire Safety Barriers in the Probabilistic Analysis of Accident Scenarios Triggered by Lightning Strike on Atmospheric Storage Tanks
    Benkaouha, Bilal
    Chiremsel, Zakarya
    Bellala, Djamel
    [J]. JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2022, 22 (06) : 2326 - 2351
  • [4] Atmospheric storage tanks
    Murti, Gopal
    [J]. CHEMICAL ENGINEERING, 2017, 124 (06) : 7 - 7
  • [5] Designing Atmospheric Storage Tanks
    Kenkre, Prasanna
    [J]. CHEMICAL ENGINEERING, 2017, 124 (03) : 77 - 82
  • [6] LIGHTNING PROTECTION FOR METAL PRODUCTION STORAGE TANKS
    LIGHTFOOT, FK
    [J]. PROFESSIONAL SAFETY, 1985, 30 (03): : 21 - 23
  • [7] Quantification of Risk Reduction Due to the Installation of Different Lightning Protection Solutions for Large Atmospheric Storage Tanks
    Necci, Amos
    Antonioni, Giacomo
    Cozzani, Valerio
    Borghetti, Alberto
    Nucci, Carlo Alberto
    [J]. CISAP6: 6TH INTERNATIONAL CONFERENCE ON SAFETY & ENVIRONMENT IN PROCESS & POWER INDUSTRY, 2014, 36 : 481 - +
  • [8] CALCULUS METHOD FOR THE ATMOSPHERIC STORAGE TANKS
    TEODORESCU, S
    [J]. REVISTA DE CHIMIE, 1985, 36 (05): : 452 - 459
  • [9] NONDESTRUTIVE TESTING TECHNIQUE FOR ATMOSPHERIC STORAGE TANKS
    Ding, Shoubao
    Liu, Fujun
    Xu, Yanting
    Guo, Xiaolian
    [J]. PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, VOL 1, 2009, : 509 - 517
  • [10] The effects of extreme winds on atmospheric storage tanks
    Ramirez Olivar, Oscar J.
    Zuluaga Mayorga, Santiago
    Munoz Giraldo, Felipe
    Sanchez-Silva, Mauricio
    Pinelli, Jean-Paul
    Salzano, Ernesto
    [J]. RELIABILITY ENGINEERING & SYSTEM SAFETY, 2020, 195