.Interpretation of the Lempel-Ziv complexity measure in the context of biomedical signal analysis

被引:273
|
作者
Aboy, Mateo [1 ]
Hornero, Roberto
Abasolo, Daniel
Alvarez, Daniel
机构
[1] Oregon Inst Technol, Elect Engn Technol Dept, Beaverton, OR 97006 USA
[2] Univ Valladolid, Dept Signal Theory & Commun, ETSIT, E-47071 Valladolid, Spain
关键词
complex analysis; Lempel-Ziv complexity (LZ); nonlinear analysis;
D O I
10.1109/TBME.2006.883696
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Lempel-Ziv complexity (LZ) and derived LZ algorithms have been extensively used to solve information theoretic problems such as coding and lossless data compression. In recent years, LZ has been widely used in biomedical applications to estimate the complexity of discrete-time signals. Despite its popularity as a complexity measure for biosignal analysis, the question of LZ interpretability and its relationship to other signal parameters and to other metrics has not been previously addressed. We have carried out an investigation aimed at gaining a better understanding of the LZ complexity itself, especially regarding its interpretability as a biomedical signal analysis technique. Our results indicate that LZ is particularly useful as a scalar metric to estimate the bandwidth of random processes and the harmonic variability in quasi-periodic signals.
引用
收藏
页码:2282 / 2288
页数:7
相关论文
共 50 条
  • [2] Interpretation of Coarse-Graining of Lempel-Ziv Complexity Measure in ECG Signal Analysis
    Zhou, Shijie
    Zhang, Zichen
    Gu, Jason
    [J]. 2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 2716 - 2719
  • [3] A permutation Lempel-Ziv complexity measure for EEG analysis
    Bai, Yang
    Liang, Zhenhu
    Li, Xiaoli
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2015, 19 : 102 - 114
  • [4] Lempel-Ziv and Multiscale Lempel-Ziv Complexity in Depression
    Kalev, K.
    Bachmann, M.
    Orgo, L.
    Lass, J.
    Hinrikus, H.
    [J]. 2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 4158 - 4161
  • [5] Multistate Lempel-Ziv (MLZ) Index Interpretation as a Measure of Amplitude and Complexity Changes
    Sarlabous, Leonardo
    Torres, Abel
    Fiz, Jose A.
    Gea, Joaquim
    Galdiz, Juan B.
    Jane, Raimon
    [J]. 2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 4375 - +
  • [6] A Lempel-Ziv complexity measure for muscle fatigue estimation
    Talebinejad, Mehran
    Chan, Adrian D. C.
    Miri, Ali
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2011, 21 (02) : 236 - 241
  • [7] The revealing of periods in Lempel-Ziv complexity of EEG signal
    Mekler, A.
    Borisenok, S. V.
    [J]. INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2018, 131 : S116 - S116
  • [8] On Lempel-Ziv complexity of sequences
    Doganaksoy, Ali
    Gologlu, Faruk
    [J]. SEQUENCES AND THEIR APPLICATIONS - SETA 2006, 2006, 4086 : 180 - 189
  • [9] Analysis of biomedical signals by the Lempel-Ziv complexity: the effect of finite data size
    Hu, Jing
    Gao, Jianbo
    Principe, Jose C.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (12) : 2606 - 2609
  • [10] On Lempel-Ziv complexity for multidimensional data analysis
    Zozor, S
    Ravier, P
    Buttellic, O
    [J]. PHYSICA A-STATISTICAL MECHANICS AND ITS APPLICATIONS, 2005, 345 (1-2) : 285 - 302