Applications of packed-column SFC using light-scattering detection

被引:26
|
作者
Berry, AJ
Ramsey, ED
Newby, M
Games, DE
机构
[1] AMERSHAM INT PLC,FOREST FARM,CARDIFF,S GLAM,WALES
[2] UNIV COLL SWANSEA,MASS SPECTROMETRY RES UNIT,SWANSEA SA2 8PP,W GLAM,WALES
关键词
D O I
10.1093/chromsci/34.5.245
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The application of packed-column supercritical fluid chromatography using ultraviolet and evaporative light-scattering detection in series for the analysis of a range of polar, nonchromophoric analytes is reported. Cyano-, amino-, silica, and β-cyclodextrin columns were used with carbon dioxide-methanol, carbon dioxide-methoxyethanol, or chlorodifluoromethane-methanol mobile phases. The performance of the system is dependent on the geometry of the nebulizer spray device in addition to the temperature and pressure (density) of the mobile phase and the percentage of solvent entraîner used. However, this may be optimized by adjustment of the nebulizer gas pressure and drift tube temperature of the detector. The technique offers a means of separating and detecting a wide range of organic compounds not normally directly amenable to high-performance liquid chromatography or supercritical fluid Chromatographic analysis using ultraviolet detection and provides a rapid means of confirming optimum component separation and the purity of samples. The applicability of the technique is illustrated by analysis of mixtures of steroids, underivatized amino acids, underivatized carbohydrates, and ionophores, by the separation of plant pigments within a leaf extract, and by the confirmation of the purity of a peptide standard.
引用
收藏
页码:245 / 253
页数:9
相关论文
共 50 条
  • [1] RECENT ADVANCES IN PACKED-COLUMN SFC
    PACHOLEC, F
    BOYER, DS
    HOUCK, RK
    ROSSELLI, AC
    [J]. MODERN SUPERCRITICAL FLUID CHROMATOGRAPHY, 1988, : 17 - 43
  • [2] CAPILLARY AND PACKED-COLUMN SFC/MS
    BERRY, AJ
    GAMES, DE
    MYLCHREEST, IC
    PERKINS, JR
    PLEASANCE, S
    [J]. JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (01): : 61 - 64
  • [3] INVESTIGATION OF RETENTION BEHAVIOR IN PACKED-COLUMN SFC
    UPNMOOR, D
    BRUNNER, G
    [J]. BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1989, 93 (09): : 1009 - 1015
  • [4] Packed-column SFC in the pharmaceutical industry: cGMP aspects
    Anton, K
    Siffrin, C
    [J]. ANALUSIS, 1999, 27 (08) : 691 - 701
  • [5] Feasibility of Phospholipids Separation by Packed Column SFC with Mass Spectrometric and Light Scattering Detection
    H. S. H. Yip
    M. Ashraf-Khorassani
    L. T. Taylor
    [J]. Chromatographia, 2007, 65 : 655 - 665
  • [6] Feasibility of phospholipids separation by packed column SFC with mass spectrometric and light scattering detection
    Yip, H. S. H.
    Ashraf-Khorassani, M.
    Taylor, L. T.
    [J]. CHROMATOGRAPHIA, 2007, 65 (11-12) : 655 - 665
  • [7] DIRECT ENANTIOMERIC RESOLUTION OF IBUPROFEN AND FLURBIPROFEN BY PACKED-COLUMN SFC
    WILSON, WH
    [J]. CHIRALITY, 1994, 6 (03) : 216 - 219
  • [8] EVALUATION OF SAMPLE INTRODUCTION TECHNIQUES OF PACKED-COLUMN SFC INTO AN MIP
    MOTLEY, CB
    LONG, GL
    [J]. APPLIED SPECTROSCOPY, 1990, 44 (04) : 667 - 672
  • [9] THE APPLICATION OF CAPILLARY SFC, PACKED-COLUMN SFC, AND CAPILLARY SFC-MS IN THE ANALYSIS OF CONTROLLED DRUGS
    MACKAY, GA
    REED, GD
    [J]. HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1991, 14 (08): : 537 - 541
  • [10] PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY WITH LIGHT-SCATTERING DETECTION .2. RETENTION BEHAVIOR OF SQUALANE AND GLUCOSE WITH MIXED MOBILE PHASES
    UPNMOOR, D
    BRUNNER, G
    [J]. CHROMATOGRAPHIA, 1992, 33 (5-6) : 261 - 266