Retrospective Camera-Based Respiratory Gating in Clinical Whole-Heart 4D Flow MRI

被引:6
|
作者
Gottwald, Lukas M. [1 ]
Blanken, Carmen P. S. [1 ]
Tourais, Joao [2 ,3 ,4 ]
Smink, Jouke [2 ]
Planken, R. Nils [5 ]
Boekholdt, S. Matthijs [5 ]
Meijboom, Lilian J. [1 ]
Coolen, Bram F. [6 ]
Strijkers, Gustav J. [6 ]
Nederveen, Aart J. [1 ]
van Ooij, Pim [1 ]
机构
[1] Univ Amsterdam, Med Ctr, Locat AMC, Radiol & Nucl Med, Amsterdam, Netherlands
[2] Philips Healthcare, MR R&D Clin Sci, Best, Netherlands
[3] Eindhoven Univ Technol, Biomed Engn, Eindhoven, Netherlands
[4] Delft Univ Technol, Dept Imaging Phys, Magnet Resonance Syst Lab, Delft, Netherlands
[5] Univ Amsterdam, Cardiol, Med Ctr, Amsterdam, Netherlands
[6] Univ Amsterdam, Biomed Engn & Phys, Med Ctr, Amsterdam, Netherlands
关键词
Camera; navigator; respiratory gating; 4D flow MRI; CARDIOVASCULAR MAGNETIC-RESONANCE; PROSPECTIVE MOTION-CORRECTION; 4-DIMENSIONAL FLOW; ACQUISITION;
D O I
10.1002/jmri.27564
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Respiratory gating is generally recommended in 4D flow MRI of the heart to avoid blurring and motion artifacts. Recently, a novel automated contact-less camera-based respiratory motion sensor has been introduced. Purpose To compare camera-based respiratory gating (CAM) with liver-lung-navigator-based gating (NAV) and no gating (NO) for whole-heart 4D flow MRI. Study Type Retrospective. Subjects Thirty two patients with a spectrum of cardiovascular diseases. Field Strength/Sequence A 3T, 3D-cine spoiled-gradient-echo-T1-weighted-sequence with flow-encoding in three spatial directions. Assessment Respiratory phases were derived and compared against each other by cross-correlation. Three radiologists/cardiologist scored images reconstructed with camera-based, navigator-based, and no respiratory gating with a 4-point Likert scale (qualitative analysis). Quantitative image quality analysis, in form of signal-to-noise ratio (SNR) and liver-lung-edge (LLE) for sharpness and quantitative flow analysis of the valves were performed semi-automatically. Statistical Tests One-way repeated measured analysis of variance (ANOVA) with Wilks's lambda testing and follow-up pairwise comparisons. Significance level of P <= 0.05. Krippendorff's-alpha-test for inter-rater reliability. Results The respiratory signal analysis revealed that CAM and NAV phases were highly correlated (C = 0.93 +/- 0.09, P < 0.01). Image scoring showed poor inter-rater reliability and no significant differences were observed (P >= 0.16). The image quality comparison showed that NAV and CAM were superior to NO with higher SNR (P = 0.02) and smaller LLE (P < 0.01). The quantitative flow analysis showed significant differences between the three respiratory-gated reconstructions in the tricuspid and pulmonary valves (P <= 0.05), but not in the mitral and aortic valves (P > 0.05). Pairwise comparisons showed that reconstructions without respiratory gating were different in flow measurements to either CAM or NAV or both, but no differences were found between CAM and NAV reconstructions. Data Conclusion Camera-based respiratory gating performed as well as conventional liver-lung-navigator-based respiratory gating. Quantitative image quality analysis showed that both techniques were equivalent and superior to no-gating-reconstructions. Quantitative flow analysis revealed local flow differences (tricuspid/pulmonary valves) in images of no-gating-reconstructions, but no differences were found between images reconstructed with camera-based and navigator-based respiratory gating. Level of Evidence 3 Technical Efficacy Stage 2
引用
收藏
页码:440 / 451
页数:12
相关论文
共 50 条
  • [1] Whole-heart 4D flow can be acquired with preserved quality without respiratory gating facilitating clinical use
    Mikael Kanski
    Johannes Töger
    Katarina Steding-Ehrenborg
    Christos G Xanthis
    Karin Markenroth Bloch
    Einar Heiberg
    Marcus Carlsson
    Håkan Arheden
    [J]. Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [2] Improved respiratory navigator gating for thoracic 4D flow MRI
    van Ooij, Pim
    Semaan, Edouard
    Schnell, Susanne
    Giri, Shivraman
    Stankovic, Zoran
    Carr, James
    Barker, Alex J.
    Markl, Michael
    [J]. MAGNETIC RESONANCE IMAGING, 2015, 33 (08) : 992 - 999
  • [3] Prerequisites for Clinical Implementation of Whole-Heart 4D-Flow MRI: A Delphi Analysis
    van Schuppen, Joost
    van der Hulst, Annelies E.
    den Harder, J. Michiel
    Gottwald, Lukas M.
    van Luijk, Raschel D.
    van den Noort, Josien C.
    Nelissen, Jules L.
    Coerkamp, Casper F.
    Boekholdt, S. Matthijs
    Groot, Paul F. C.
    Nederveen, Aart
    van Ooij, Pim
    Planken, R. Nils
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024,
  • [4] Whole-heart 4D flow cardiac magnetic resonance in healthy dogs
    Pfammatter, N. S.
    Campagna, I. U.
    Toaldo, M. Baron
    Bruellmann, E.
    Richter, H.
    Kircher, P. R.
    Dennler, M.
    [J]. SCHWEIZER ARCHIV FUR TIERHEILKUNDE, 2018, 160 (05): : 295 - 303
  • [5] 4D flow of the whole heart and great vessels using real time self respiratory gating
    Sergio A Uribe Arancibia
    Philipp Beerbaum
    Allan Rasmusson
    Thomas Sangild Sørensen
    Reza Razavi
    Tobias Schaeffter
    [J]. Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [6] Impact of Respiratory Gating on Hemodynamic Parameters from 4D Flow MRI
    Denecken, Esteban
    Sotelo, Julio
    Arrieta, Cristobal
    Andia, Marcelo E.
    Uribe, Sergio
    [J]. APPLIED SCIENCES-BASEL, 2022, 12 (06):
  • [7] Editorial for "Prerequisites for Clinical Implementation of Whole-Heart 4D-Flow MRI: A Delphi Analysis"
    Morales, Manuel A.
    Nezafat, Reza
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024,
  • [8] Self-gated 4D whole-heart imaging
    Jianing Pang
    Debiao Li
    [J]. Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [9] Whole-heart cine MRI using real-time respiratory self-gating
    Uribe, Sergio
    Muthurangu, Vivek
    Boubertakh, Redha
    Schaeffter, Tobias
    Razavi, Reza
    Hill, Derek L. G.
    Hansen, Michael S.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (03) : 606 - 613
  • [10] Automatic Whole-Heart Segmentation in 4D TAVI Treatment Planning CT
    Bruns, Steffen
    Wolterink, Jelmer M.
    van den Boogert, Thomas P. W.
    Henriques, Jose P.
    Baan, Jan
    Planken, R. Nils
    Isgum, Ivana
    [J]. MEDICAL IMAGING 2021: IMAGE PROCESSING, 2021, 11596