Test beam analysis of the first CMS drift tube muon chamber

被引:7
|
作者
Albajar, C
Amapane, N
Arce, P
Autermann, C
Bellato, M
Benettoni, M
Benvenuti, A
Bontenackels, M
Caballero, J
Cavallo, FR
Cerrada, M
Cirio, R
Colino, N
Conti, E
de la Cruz, B
Dal Corso, F
Dallavalle, GM
Fernández, C
de Trocóniz, JF
Fouz, MC
García-Abia, P
García-Raboso, A
Gasparini, F
Gasparini, U
Giacomelli, P
Gonella, F
Gulmini, M
Hebbeker, T
Hermann, S
Hoepfner, K
Jiménez, I
Josa, I
Lacaprara, S
Marcellini, S
Mariotti, C
Maron, G
Maselli, S
Meneguzzo, AT
Monaco, V
Montanari, A
Montanari, C
Montecassiano, F
Navarria, FL
Odorici, F
Passaseo, M
Pegoraro, M
Peroni, C
Perrotta, A
Puerta, J
Reithler, H
机构
[1] Univ Autonoma Madrid, Dept Fis Teor C XI, E-28049 Madrid, Spain
[2] Univ Turin, Ist Nazl Fis Nucl, Turin, Italy
[3] CIEMAT, Div Fis Particulas, Madrid, Spain
[4] Rhein Westfal TH Aachen, Inst Phys 3, D-5100 Aachen, Germany
[5] Ist Nazl Fis Nucl, Lab Nazl Legnaro, I-35020 Legnaro, Italy
[6] Univ Padua, Padua, Italy
[7] Ist Nazl Fis Nucl, Padua, Italy
[8] Univ Bologna, Bologna, Italy
[9] Ist Nazl Fis Nucl, I-40126 Bologna, Italy
关键词
LHC; CMS; muon detector; drift tubes;
D O I
10.1016/j.nima.2004.01.080
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In October 2001 the first produced CMS Barrel Drift Tube (DT) Muon Chamber was tested at the CERN Gamma Irradiation Facility (GIF) using a muon beam. A Resistive Plate Chamber (RPC) was attached to the top of the DT chamber, and, for the first time, both detectors were operated coupled together. The performance of the DT chamber was studied for several operating conditions, and for gamma rates similar to the ones expected at LHC. In this paper we present the data analysis; the results are considered fully satisfactory. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:465 / 484
页数:20
相关论文
共 50 条
  • [1] Construction and test of the final CMS Barrel Drift Tube Muon Chamber prototype
    Aguilar-Benítez, M
    Alberdi, J
    Arneodo, M
    Banicz, K
    Benettoni, M
    Benvenuti, A
    Bethke, S
    Cerrada, M
    Cirio, R
    Colino, N
    Conti, E
    Dallavalle, M
    Daniel, M
    Dattola, D
    Daudo, F
    De Giorgi, M
    Dosselli, U
    Fanfani, A
    Fanin, C
    Fouz, MC
    Gasparini, F
    Gasparini, U
    Giacomelli, P
    Giordano, V
    Gonella, F
    Grandi, C
    Guaita, P
    Guerzoni, M
    Lacaprara, S
    Lippi, I
    Marcellini, S
    Marín, J
    Martinelli, R
    Maselli, S
    Meneguzzo, A
    Migliore, E
    Mocholí, J
    Monaco, V
    Montanari, A
    Montanari, C
    Odorici, F
    Oller, JC
    Paoletti, S
    Passaseo, M
    Pegoraro, M
    Peroni, C
    Puerta, J
    Reithler, H
    Romero, A
    Romero, L
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 480 (2-3): : 658 - 669
  • [2] Bunched beam test of the CMS drift tubes local muon trigger
    Arce, P
    Bellato, M
    Benettoni, M
    Benvenuti, A
    Bonacorsi, D
    Bontenackels, M
    Caballero, J
    Cafaro, V
    Capiluppi, P
    Castellani, L
    Cavallo, FR
    Cerrada, M
    Checchia, P
    Colino, N
    Conti, E
    Corvo, M
    de la Cruz, B
    Dal Corso, F
    Dallavalle, GM
    De Giorgi, M
    Fabbri, E
    Fanfani, A
    Fernandez, C
    de Trocóniz, JE
    Fouz, MC
    Abia, P
    Gasparini, F
    Gasparini, U
    Giacomelli, P
    Giordano, V
    Gonella, F
    Grandi, C
    Guiducci, L
    Gulmini, M
    Hebbeker, I
    Hernandez, JM
    Hoepfner, K
    Josa, I
    Lacaprara, S
    Lippi, I
    Mameghani, R
    Marcellini, S
    Maron, G
    Martinelli, R
    Maselli, S
    Masetti, G
    Meneguzzo, AT
    Meng, G
    Monaco, V
    Montanari, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 534 (03): : 441 - 485
  • [3] Results of the first integration test of the CMS drift tubes muon trigger
    Aldaya, M.
    Amapane, N.
    Argiro, S.
    Battilana, C.
    Bellan, R.
    Bellato, M.
    Benvenuti, A.
    Boldini, M.
    Bolognesi, S.
    Bontenackels, M.
    Borsato, E.
    Bralbant, S.
    Cafaro, V.
    Capiluppi, P.
    Castellani, L.
    Cavallo, F. R.
    Cerminara, G.
    Cerrada, M.
    Cheechia, P.
    Conti, E.
    de la Cruz, B.
    Dal Corso, F.
    Dallavalle, G. M.
    Deldicque, C.
    Dellacasa, G.
    Eroe, J.
    Fanfani, A.
    Fernandez, C.
    de Troconiz, J. Fernandez
    Fouz, M. C.
    Gasparini, F.
    Gasparini, U.
    Giacomelli, P.
    Giordano, V.
    Giunta, M.
    Gonella, F.
    Guiducci, L.
    Hebbeker, T.
    Hoepfner, K.
    Jimenez, I.
    Josa, I.
    Lacaprara, S.
    Lippi, I.
    Marcellini, S.
    Mariotti, C.
    Maron, G.
    Maselli, S.
    Masetti, G.
    Meneguzzo, A. T.
    Mila, G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (03): : 951 - 960
  • [4] The Drift Tube Barrel Muon Trigger at the CMS experiment
    de Troconiz, J. F.
    [J]. NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2007, 172 : 171 - 173
  • [5] The drift tube track finder muon trigger at the CMS
    Jiménez, I
    [J]. CZECHOSLOVAK JOURNAL OF PHYSICS, 2005, 55 : B819 - B824
  • [6] Irradiation aging of the CMS Drift Tube muon detector
    Redondo Ferrero, D. D.
    Abbiendi, G.
    Alcaraz Maestre, J.
    Alvarez Fernandez, A.
    Alvarez Gonzalez, B.
    Amapane, N.
    Bachiller, I.
    Barcala, J. M.
    Barcellan, L.
    Battilana, C.
    Bellato, M.
    Bencze, G.
    Benettoni, M.
    Beni, N.
    Benvenuti, A.
    Blanco Ramos, L. C.
    Boletti, A.
    Bragagnolo, A.
    Brochero Cifuentes, J. A.
    Cafaro, V.
    Calderon, A.
    Calvo, E.
    Cappati, A.
    Carlin, R.
    Carrillo Montoya, C. A.
    Caturan, S.
    Cavallo, F. R.
    Cela Ruiz, J. M.
    Cepeda, M.
    Cerrada, M.
    Chazin Quero, B.
    Checchia, P.
    Ciano, L.
    Colino, N.
    Corti, D.
    Cotto, G.
    Cuevas, J.
    Cuffiani, M.
    Dallavalle, G. M.
    Dattola, D.
    De La Cruz, B.
    De Remigis, P.
    de Troconiz, J. F.
    Erice Cid, C.
    Bedoya, C. F.
    Fabbri, F.
    Fanfani, A.
    Fasanella, D.
    Fernandez Manteca, P.
    Fernandez Menendez, J.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2020, 172
  • [7] Performance and Future Upgrades of the CMS Drift Tube Muon Detector
    Redondo, D. D.
    [J]. 2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [8] 40 MHz triggerless readout of the CMS Drift Tube muon detector
    Migliorini, M.
    Pazzini, J.
    Triossi, A.
    Zanetti, M.
    [J]. JOURNAL OF INSTRUMENTATION, 2024, 19 (02)
  • [9] Performance tests of the Drift Tube Muon chambers for the CMS experiment at the LHC
    Cavallo, FR
    [J]. NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2003, 125 : 206 - 211
  • [10] Electronics for the CMS Muon drift tube chambers:: The read-out minicrate
    Bedoya, CF
    Marín, J
    Oller, JC
    Willmott, C
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) : 944 - 949