Use of Flow Cytometry as a Quality Control Device for Liquid-Based Cervical Cytology Specimens

被引:4
|
作者
Kottaridi, Christine [1 ]
Georgoulakis, John [1 ]
Kassanos, Dimitrios [2 ]
Pappas, Asimakis [2 ]
Spathis, Aris [1 ]
Margari, Niki [1 ]
Aninos, Dionissios [1 ]
Karakitsos, Petros [1 ]
机构
[1] Univ Gen Hosp Attikon, Dept Diagnost Cytopathol, Athens 12462, Greece
[2] Univ Gen Hosp Attikon, Dept Obstet & Gynecol 3, Athens, Greece
关键词
flow cytometry; adequacy; LBC specimens; ADEQUACY; SMEAR;
D O I
10.1002/cyto.b.20491
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Cervical cancer is the second most common cancer in women worldwide comprising a major concern of public health. Liquid-based cytology provides significantly more effective detection of low-grade intraepithelial neoplasia or more severe lesions, without loss of diagnostic specificity and reduces the number of cases classified as unsatisfactory. The objective of the study is the evaluation of flow cytometry as a rapid tool for quality control of the liquid specimen adequacy for the purpose of precise cytological diagnosis in detecting cervical abnormalities. Methods: A total of 1,854 women undergoing routine cervical cytology joined this cohort study. A monolayer smear was prepared and 1 ml aliquot was removed and prepared for flow cytometric analysis. Cells were fixed and run on a Partec CyFlow SL, with front scatter (FSS) and side scatter (SSC) set on logarithmic scale. The forward scatter versus side scatter dot-plot was used for the distinction of ecto-cervical, endocervical, and polymorphonuclear cells. Results: In the total of 1,854 cases, 15 specimens (0.8%) were characterized by the cytopathologist as unsatisfactory. Inadequacy was confirmed by flow cytometric analysis for four samples. Monolayer smears were reprepared for the remaining 11 samples. After the second microscopic observation, six out of the 11 cases (54.5%) were found to be satisfactory, whereas the remaining five were still designated as unsatisfactory by the cytopathologist. Conclusion: The parallel screening of adequacy by quantification of cell populations with flow cytometry can serve as an internal control for diagnosis and can overall decrease the number of unsatisfactory samples. (C) 2009 Clinical Cytometry Society
引用
收藏
页码:37 / 40
页数:4
相关论文
共 50 条
  • [1] Control specimens for immunocytochemistry in liquid-based cytology
    Hansen, T.
    Pedersen, H.
    Brauner, V.
    Hariri, J.
    [J]. CYTOPATHOLOGY, 2011, 22 (04) : 243 - 246
  • [2] Determination of liquid-based cervical cytology specimen adequacy using cellular light scatter and flow cytometry
    Grundhoefer, D
    Patterson, BK
    [J]. CYTOMETRY, 2001, 46 (06): : 340 - 344
  • [3] Sip volume as a quality indicator in liquid-based cervical cytology
    Sherman, Mark E.
    Kahler, Jessica
    Gustafson, Karen S.
    Wang, Sophia S.
    [J]. CANCER CYTOPATHOLOGY, 2006, 108 (06) : 462 - 467
  • [4] Liquid-based cervical cytology: Monitoring the laboratory quality indicators
    Nayak, Sonali Susmita
    Dutta, Anupurva
    Khedkar, Rutvij
    Roy, Sabyasachi
    [J]. JOURNAL OF CYTOLOGY, 2024, 41 (01) : 1 - 7
  • [5] Liquid-based cervical cytology tests
    Sulik, SM
    Becker, LA
    Grant, WD
    [J]. JOURNAL OF FAMILY PRACTICE, 2002, 51 (04): : 378 - 378
  • [6] Liquid-based cytology for cervical screening
    Payne, N
    Chilcott, J
    McGoogan, E
    [J]. CYTOPATHOLOGY, 2000, 11 (06) : 469 - 470
  • [7] ProExC Triage of Atypical Glandular Cells on Liquid-Based Cervical Cytology Specimens
    Fletcher, Andrew Hamilton
    Barklow, Thomas A.
    Murphy, Nina J.
    Culbertson, Leah H.
    Davis, Angie V.
    Hunter, Louise
    [J]. JOURNAL OF LOWER GENITAL TRACT DISEASE, 2011, 15 (01) : 6 - 10
  • [8] Assessment of DNA methylation for the detection of cervical neoplasia in liquid-based cytology specimens
    Kim, Jo-Heon
    Choi, Yoo Duk
    Lee, Ji Shin
    Lee, Jae Hyuk
    Nam, Jong Hee
    Choi, Chan
    [J]. GYNECOLOGIC ONCOLOGY, 2010, 116 (01) : 99 - 104
  • [9] Using a quality control approach to define an 'adequately cellular' liquid-based cervical cytology specimen
    McQueen, F.
    Duvall, E.
    [J]. CYTOPATHOLOGY, 2006, 17 (04) : 168 - 174
  • [10] Diagnostic Value of Liquid-Based Cytology With Fine Needle Aspiration Specimens for Cervical Lymphadenopathy
    Bandoh, Nobuyuki
    Goto, Takashi
    Akahane, Toshiaki
    Ohnuki, Natsumi
    Yamaguchi, Tomomi
    Kamada, Hajime
    Harabuchi, Yasuaki
    Tanaka, Shinya
    Nishihara, Hiroshi
    [J]. DIAGNOSTIC CYTOPATHOLOGY, 2016, 44 (03) : 169 - 176